Closed loop Hall current sensor
Closed loop Hall current sensor
Closed loop Hall current sensor

1 / 1

Closed loop Hall current sensor

Get Latest Price

Options:

  • THB_ES5S6H
Send Inquiry
Model No. : THB_ES5S6H
Brand Name :
place of origin : China
use : Electronic
Coil structure : Toroidal
More
2yrs

Zibo, Shandong, China

Visit The Store
  • Gold Supplier
  • Platform Certification

Product description

Product introduction

Application

Ø Power supply: +5v DC;

Ø Installation method: PCB installation;

Ø Hall effect principle - closed loop current sensor;

Ø The primary and secondary of the current sensor are insulated and can measure DC, AC, pulse, etc;

Ø Application on Inverter

Ø Ac/dc variable speed drive

Ø Switching power supply (SMPS)

Ø UPS uninterruptible power supply

Ø Application of frequency converter

         Electrical characteristics

Parameter

Symbol

THB10ES5S6H

THB25ES5S6H

THB50ES5S6H

THB75ES5S6H

Rated current

IPN(A)

10

25

50

75

Measuring range

IP(A)

0~±32

0~±80

0~±120

0~±150

Coil turn ratio

NP/NS

1:800

1:2000

1:2000

1:2000

Measure resistance

RM

50±0.1%

50±0.1%

25±0.1%

16.5±0.1%

Output voltage

VO(V)

2.5±0.625*(IP/IPN)

Offset voltage

VOE(mV)

<±10

Working power supply

VC(V)

+5V DC±5%

Insulation voltage

VD(V)

50/60Hz1min3kVRMS

         General parameters

Project

Condition

Date

Unit

Accuracy XG

@ IPN,T=25

<±0.5

%

Zero offset voltage VOE

@ IP=0,T=25

<±10

mV

Current offset temperature drift VOT

@ IP=0,-40+85

<±0.05

mV/

Linearity εr

0.1

%FS

Follow accuracy di/dt

50

A/µs

Response time tra

@ 90% of IPN

<1.0

μs

Operating bandwidth BW

-3dB

DC-200

kHZ

Working temperature TA

-40+85

Storage temperature TS

-55+125

Static power consumption IC

10+Is

mA

Product weight m

13

g

Shell material

PBT material containing 30% glass fiberFlame retardant gradeUL94- V0;

Standard

IEC60950-1:2001    EN50178:1998    SJ20790-2000

         Structural drawing: (mm)

THB_ES5S6 2D

         Connection diagram:

                            Thb Es5s6 Jx

Remarks:

1. When the measured current passes through the primary pin of the sensor, there is a corresponding voltage signal output at the output end;(Note: wrong wiring may damage the sensor)

2. Products with different rated current can be designed according to the requirements of customers, and the output voltage of the sensor can be selected;

3. When the busbar is fully filled with holes, the dynamic performance is the best;

4. The temperature of primary conductor shall not exceed 100;



Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628