Specifications 1.Hypochlorite generator from seawater
2.Convenient maintenance
3.Patented electrode
4.Transparent electrolyzing tube
5.ISO
Micro-electrolysis equipment for Seawater Company Information 1. SCITEC world leading electro chlorination project from seawater Cooperated with the Chlorite Engineers Corp.,Ltd. Japan and Newtec GmbH Germany, Shanghai Sciyee Water Sci.&Tech. Co.,Ltd (SCITEC) has undertaken mang projects, more than on ehundren electro chlorination systems are running at home and abroad. Introduced advanced technology and product from CEC and Newtec, SCITEC adopts advanced process to prolong the service life of the electrode, improve the electro chlorination efficiency greatly and extend the acid cleaning period substantially. The electro chlorination system is extensively used in mang fields like power plant, LNG receiving station, desalinator. The reliability and economy receive lots of recognition by the end users. Product Description 1.Technical parameters Available chlorine concentration: Approximately 1000mg/L (inlet water >15°C)
(TDS:38~40g/l)
Power input: 380V, three-phase, 50Hz
Design pressure: 0.6 MPa
Electrode life: ≥5 year
Acidic washing period: ≥30 day
Design temperature: 50°C
DC consumption: 3.51 KWh/kg Cl2
(Cl - : 15000ppm, inlet water 25°C)
AC consumption: 3.90 KWh/kg Cl2
(Cl - : 15000ppm, inlet water 25°C)
Unit size:
NT-5000H - NT-20000H:
1600 (length) ×1000 (width) ×3000 (Max. height)
NT-30000H~NT-40000H:
1600 (length) ×1600 (width) ×3000 (Max. height)
NT-60000H~NT-80000H:
4000 (length) ×1000 (width) ×2800 (Max. height)
2. A tipical electro chlorination system The advanced electrode technology is applied in the electro chlorination system, which can produce the sodium hypochlorite solution with the concentration 200-2500ppm. The sodium hypochlorite can be stored in the tanks for later dosing/shock dosing in order to prevent biofouling, the growth of algae and shelf-fish. Avaliable chlorite production of electrolysis module ranges from 1 to 10 kg/h by increasing the electrolysis modules. The largest chlorite production capacity of single equipment is up to 100kg/h, larger equipments can be customized. Model table
Model | Available Cl2 | Flow rate | AC consumption | Available Cl2 concentration | (Reference) Treatment of cooling water |
Dosing rate | Cooling water flow |
Kg/h | M³/h | kw | ppm | ppm | M³/h |
NT-H-1000 | 1 | 5 | 4.1 | 200 | 1 | 1,000 |
NT-H-2000 | 2 | 5 | 8.2 | 400 | 1 | 2,000 |
NT-H-5000 | 5 | 5 | 20.6 | 1000 | 1 | 5,000 |
NT-H-8000 | 8 | 5 | 32.9 | 1600 | 1 | 8,000 |
NT-H-10000 | 10 | 5 | 41.1 | 2000 | 1 | 10,000 |
NT-H-15000 | 15 | 15 | 61.7 | 1000 | 1 | 15,000 |
NT-H-25000 | 25 | 12.5 | 102.8 | 2000 | 1 | 25,000 |
NT-H-40000 | 40 | 26.7 | 164.4 | 1500 | 1 | 40,000 |
NT-H-50000 | 50 | 25 | 205.6 | 2000 | 1 | 50,000 |
NT-H-80000 | 80 | 26.7 | 328.9 | 1500 | 1 | 80,000 |
NT-H-100000 | 100 | 25 | 411.1 | 2000 | 1 | 100,000 |
Design key points: Consulting us about model selection when the temperature of inlet seawater is below 15°C or salt concentration of inlet seawater is below 38g/L, for electrolysis efficiency will be reduced. Unit size does not include storage tank, choose it according to specific conditions. Rectifier does not require a single room for the electrolysis unit is sealed. Generated hydrogen is diluted to safe concentration and then discharged outside of the room by blower, the equipment room must have good ventilation equipments and four ventilation pipes connecting to outside on the four corners, wind hat is required outside the room.