Product description
Characteristics:
- 15-inch TFT display
- Resolution: 1,024 x 768 pixels
- Anti-ESU and -defibrillator
- Capture dynamic waveforms
- Can be used for animals
- Trend coexist display
- Spo2 testing to 0.1% weak
- Bed-to-bed view display
- Networking capacity and nurse-calling system
- ECG, SPO2, PR, NIBP, RR and temperature
Functions:
- With 6 display interfaces
- 720-hour trend data storage and 12-hour waveform review
- Voice alarm
- Supports wired and wireless networking
- Supports software upgrade online
- ST segment can be adjusted
- Supports nurse call system
Specifications:
- ECG:
- Lead mode: 5 leads
- Gain: 1/4, 1/2, 1, 2 and 4mm/mV
- Scanning speed: 12.5, 25 and 50mm/S
- Frequency response:
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
- NIBP:
- Measure and alarm range
- Adult mode:
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
- Pediatric mode:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- Neonatal mode:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Static pressure range: 0 to 300mmHg
- Static pressure accuracy: ±3mmHg or 2%
- Resolution: 1mmHg
- Protection mode and dual over-voltage protection
- SPO2:
- Measure range: 1 to 100%
- Accuracy: ±2% (70 to 100%)
- Resolution: 1%
- Pulse rate measure range: 20 to 300bpm
- Accuracy: ±2bpm
- Resolution: 1bpm
- Temperature:
- Channel: 2
- Measure range: 0 to 50°C
- Accuracy: ±0.1°C
- Resolution: 0.1°C
- Respiration:
- Measure range:
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM
- Accuracy: ±2%
- Resolution: 1bpm
- IBP (optional)
- Accuracy (no sensor): ±2% or 1mmHg
15-inch TFT display
Resolution: 1,024 x 768 pixels
Anti-ESU and -defibrillator
Capture dynamic waveforms
Can be used for animals
Trend coexist display
Spo2 testing to 0.1% weak
Bed-to-bed view display
Networking capacity and nurse-calling system
ECG, SPO2, PR, NIBP, RR and temperature
With 6 display interfaces
720-hour trend data storage and 12-hour waveform review
Voice alarm
Supports wired and wireless networking
Supports software upgrade online
ST segment can be adjusted
Supports nurse call system
ECG:
- Lead mode: 5 leads
- Gain: 1/4, 1/2, 1, 2 and 4mm/mV
- Scanning speed: 12.5, 25 and 50mm/S
- Frequency response:
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
NIBP:
- Measure and alarm range
- Adult mode:
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
- Pediatric mode:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
- Neonatal mode:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
- Static pressure range: 0 to 300mmHg
- Static pressure accuracy: ±3mmHg or 2%
- Resolution: 1mmHg
- Protection mode and dual over-voltage protection
SPO2:
- Measure range: 1 to 100%
- Accuracy: ±2% (70 to 100%)
- Resolution: 1%
- Pulse rate measure range: 20 to 300bpm
- Accuracy: ±2bpm
- Resolution: 1bpm
Temperature:
- Channel: 2
- Measure range: 0 to 50°C
- Accuracy: ±0.1°C
- Resolution: 0.1°C
Respiration:
- Measure range:
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM
- Accuracy: ±2%
- Resolution: 1bpm
- IBP (optional)
- Accuracy (no sensor): ±2% or 1mmHg
Lead mode: 5 leads
Gain: 1/4, 1/2, 1, 2 and 4mm/mV
Scanning speed: 12.5, 25 and 50mm/S
Frequency response:
- Diagnosis: 0.05 to 130Hz
- Monitoring: 0.5 to 40Hz
- Operation: 1.0 to 20Hz
- Heart rate range: 15 to 350bpm
- Heart rate accuracy: ±1%
- ST segment analysis: -0.8 to +0.8mV
- ST segment accuracy: ±0.02mV
Diagnosis: 0.05 to 130Hz
Monitoring: 0.5 to 40Hz
Operation: 1.0 to 20Hz
Heart rate range: 15 to 350bpm
Heart rate accuracy: ±1%
ST segment analysis: -0.8 to +0.8mV
ST segment accuracy: ±0.02mV
Measure and alarm range
Adult mode:
- SYS: 40 to 280mmHg
- DIA: 10 to 220mmHg
- MEAN: 20 to 240mmHg
Pediatric mode:
- SYS: 40 to 220mmHg
- DIA: 10 to 160mmHg
- MEAN: 20 to 170mmHg
Neonatal mode:
- SYS: 40 to 135mmHg
- DIA: 10 to 100mmHg
- MEAN: 20 to 110mmHg
Static pressure range: 0 to 300mmHg
Static pressure accuracy: ±3mmHg or 2%
Resolution: 1mmHg
Protection mode and dual over-voltage protection
SYS: 40 to 280mmHg
DIA: 10 to 220mmHg
MEAN: 20 to 240mmHg
SYS: 40 to 220mmHg
DIA: 10 to 160mmHg
MEAN: 20 to 170mmHg
SYS: 40 to 135mmHg
DIA: 10 to 100mmHg
MEAN: 20 to 110mmHg
Measure range: 1 to 100%
Accuracy: ±2% (70 to 100%)
Resolution: 1%
Pulse rate measure range: 20 to 300bpm
Accuracy: ±2bpm
Resolution: 1bpm
Channel: 2
Measure range: 0 to 50°C
Accuracy: ±0.1°C
Resolution: 0.1°C
Measure range:
- Adult: 0 to 120BrPM
- Pediatric/neonatal: 0 to 150BrPM
Accuracy: ±2%
Resolution: 1bpm
IBP (optional)
Accuracy (no sensor): ±2% or 1mmHg
Adult: 0 to 120BrPM
Pediatric/neonatal: 0 to 150BrPM