Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light
Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light

1 / 10

Hair Removal, Skin Rejuvenation Treatment Ipl Laser Equipment With Intense Pulsating Light

Get Latest Price
Send Inquiry
Model No. :
Brand Name :

Product description

 Hair removal, skin rejuvenation treatment IPL Laser Equipment with intense pulsating light

 

Headpiece:

one handpiece (big spot)

Power supply:

2400 W

Light Source:

8 times of atmospheric pressure, USA

Spectrum Range:

630nm

Spot Size:

45*75mm

Cooling Manner:

semiconductor+ wind + water + cooling gel

Energy Density:

01-50J/cm2

Pulse Quantity:

3-10

Pulse Width:

1-10ms

Pulse Interval:

1-100ms

Size:

46*48 * 98 cm  

Weight:

65KG

 

1. Components of the device

◆ Main machine

Power supply system

Computer system

Cooling system

Controller

◆ Handle

Handle

Crystals

◆ Assembly parts

Key

Cleaner

Power line

Water pipe

Water funnel

Foot touch switch

Professional protective glasses

Professional protective eye patch

Accessories

1 water funnel, 1 pair eye patch, 2 pairs protective glasses, and 1 power line.

3.  Treatment Theory and Operation

One: Treatment theory

Physical stimulation effect: when it acts on skin and have the chemical effect, the intensive pulsed light makes the molecule structure change inside of the collagen fiber and flexibility fiber of dermis, and renews skin flexibility. Moreover, the light energy could enhance the blood vessel function, and improve blood circulation, to remove the wrinkle and shrink the coarse pores.

At the same time, the treatment theory of IPL series Equipments can be explained by the optional light pyrogenation theory. The melanin absorbs the short wavelength light of 250-1200nm, the maximum absorbing values of the bright-red chemical complex of hemoglobin and oxygen are 418nm, 542nm, 577nm. Therefore, it’s easy to be absorbed and transported to the collagen layer, the wavelength light of 530nm releases from the probe, which results in the pyrogenation of the collagen fiber. The collagen fiber can be able to absorb large light of 400-600nm, including some light of 530-1200nm releases from the probe, which will result in the injury of the collagen fiber, enhance the activation of the cells and the collagen synthesis. Renew of I collagen can be observed, and also be effective to the renew of III collagen, which is in blood vessel mostly. At the same time, skin rejuvenation treatment will be effective on pigments dispelling, telangiectasia lightening, fine wrinkle lightening, pores contracting and a best skin improvement.

Two:  Features

1.  Simplicity: intuitionist controller makes the operation much easier. After simple training, the operator could skillfully operate the device. Humanized design of the handle makes an easiest operation.

2.  Efficiency: best treatment effect, no side effect, makes the treatment more comfortable.

3.  Safety: in this beauty system, IPL and RF can be used together or separately, operator could choose the low light energy or the high radio frequency energy, that greatly reduce the risk of burn epidermis after the treatment. After this system treatment, almost no inflammation on face syndrome etc. So the patients are unnecessary to worry about burning skin in epidermis, which originating from over energy or the probe closely near skin

4.  Economical: best results, low cost of maintenance. Moreover, because of unnecessary higher IPL energy, prolong the lifetime of the handle for 2 or 3 years, which greatly reduce the cost. Easy daily maintenance, easy master after the simple training

5.  Wide range of treatments, great effect, and with high safety factors

4.   Applications

1.  Unwanted hair removal: take advantage of intensive pulsed light (could act on skin below 6 mm), directly act on the hair follicle to remove the thick dark hair, and tiny hair

5.   Taboos

1.  Pregnant women

2.  Insulations in the sun

3.  Sensitive to light, medicine, or are taking medicine that sensitive to light

4.  Not representative naevi or malignant pathological changes in the treatment area

5.  Pacemaker or quiver dispelling device user

6.  Herpes or trauma

7.  Pimple record

8.  People who accept Hirudin etc. treatment (should stop using it before 2 weeks ).

9.  Severe diabetes patient, high blood pressure sufferer, and epileptic

10.  Security introduction of the intensive pulsed light

【WARNING】

1.  Any intensive light without incorrect using can injure the body. In the course of working, the device will produce high pressure. So every operator should keep warning, operating according to this introduction. For this machine is more powerful than other IPL equipment , every operator and observer have to wear a protective glasses.

2.  Patient: It’s more important that seasoned operator and appropriate disposal treatment room. Moreover, the patient should also know the treatment theory and wear the professional protective eye-patch, protecting eyes from burning.

3.  Operator: During the treatment, it’s possible to touch the intensive light. So it’s necessary to wear the 3 grade blinder.

4.  Treatment room: the room must clear mark “using intensive light”

【MAIN WARNING】

1.  For safe using, should carefully read the warning notice:

2.  Except the authorized mechanic, any others have no right to examine and repair the IPL setup, especially the inside of device that including electrical source, cooling system, optic organs and handle. Notice the dangerous high pressure inside.

3.  Make sure whether it’s accordant to your resident voltage or not.

4.  Maintenance must after turning off the device and drawing out the electrical source line. Or it’s most possible to injure people and damage the equipment.

5.  Keep the filter and the probe clean. Do not let the cooling gel enter into the probe

6.  Stop turning on when finding slack from handle. If turning on, please close right now.

7.   this machine needs 10-20 minutes break after continue using 45-60 minutes, or it is in “work” status more than 45 minutes.

8.   this machine can not be used at high temperature, pyrogenic and strong magnetic field.

【WARNING ON INTENSIVE LIGHT】

1.  The intensive light is possible burn eyes or fire. So it’s necessary to protect in any way.

2.  Over light energy could burn skin, that results in atrophy or pigment deposit.

3.  Do not directly see the intensive light or laser light during treatment, even wear the protective glasses and eye-patch.

4.  Do not point the handle to the air. Generally, hang it in the bracket. Point to the treatment areas when operating.

7. Security introduction of the electricity and equipment

1.  Keep close both panels and cover board.

2.  High pressure inside the equipment. It’s possible to deposit electricity in some parts after switching off. So it’s not allowed to open equipment beyond the authorized mechanics.

3.  When maintaining, please close power, cover board, and observe in person.

4.  Total weight is 50 KGs, so please take care when moving.

【PREVENT FIRE】

1.  The temperature will rise after absorbing light energy, so please take actions to reduce the flammable risk on treatment areas or around area. For the power is 2400W, the machine will be hot very soon. So it is necessary to stop the machine 10-20minutes after continue working 45-60minutes.

2.  Do not use ethanol, acetone or other flammable things on skin before treatment. If necessary, please use soap or water.

3.  When taking off the handle or other parts in ethanol, please wait till dry.

4.  The machine can not be used at high temperature, pyrogenic and strong magnetic fields.

【SYSTEM SAFETY SETTINGS】

1.  There are some safety settings inside equipment, so please know their places and using methods.

2.  Key: it’s used to open or close the power, only provide by our company.

3.  Emergency switch: the white switch is used to switch off power on emergency. Press it can     switch off the power right now. the device keeps turning off.

【CLASS OF EQUIPMENT】

1.  Class of motor protection:1 CLASS, BF CLASS

2.  Anti-corrosive liquid: general

3.  Not allowed to use in the air mixed flammable anesthetic and nitrous oxide

4.  Operation manner: continuous operation

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628