Multifunctional 530nm / 640nm Ipl Laser Beauty Equipment For Wrinkle Removal And Face Lift
Multifunctional 530nm / 640nm Ipl Laser Beauty Equipment For Wrinkle Removal And Face Lift
Multifunctional 530nm / 640nm Ipl Laser Beauty Equipment For Wrinkle Removal And Face Lift

1 / 1

Multifunctional 530nm / 640nm Ipl Laser Beauty Equipment For Wrinkle Removal And Face Lift

Get Latest Price
Send Inquiry
Model No. :
Brand Name :

Product description

Multifunctional 530nm / 640nm IPL Laser Beauty Equipment for wrinkle removal and face lift

 

I 020--Skin photo rejuvenation system

Treatment Theory and Operation
One: Treatment theory

A. Physical stimulation effect: when it acts on skin and have the chemical effect, the intensive pulsed light makes the molecule structure change inside of the collagen fiber and flexibility fiber of dermis, and renews skin flexibility. Moreover, the light energy could enhance the blood vessel function, and improve blood circulation, to remove the wrinkle and shrink the coarse pores.

B. Light pyrogenation effect: the quantity of pigment group in ill structure is super higher than of that in the normal skin, whose temperature is also higher than of the normal skin after absorbing the light. Take advantage of the temperature difference, which will obdurate the blood vessel and decompose the pigments, without any damage on the normal structure.

At the same time, the treatment theory of IPL series Equipments can be explained by the optional light pyrogenation theory. The melanin absorbs the short wavelength light of 250-1200nm, the maximum absorbing values of the bright-red chemical complex of hemoglobin and oxygen are 418nm, 542nm, 577nm. Therefore, it’s easy to be absorbed and transported to the collagen layer, the wavelength light of 530nm releases from the probe, which results in the pyrogenation of the collagen fiber. The collagen fiber can be able to absorb large light of 400-600nm,including some light of 530-1200nm releases from the probe, which will result in the injury of the collagen fiber, enhance the activation of the cells and the collagen synthesis. Renew of I collagen can be observed, and also be effective to the renew of III collagen, which is in blood vessel mostly. At the same time, skin rejuvenation treatment will be effective on pigments dispelling, telangiectasia lightening, fine wrinkle lightening, pores contracting and a best skin improvement.

Two:  Features

1.  Simplicity: intuitionist controller makes the operation much easier. After simple training, the operator could skillfully operate the device. Humanized design of the handle makes an easiest operation.

2.  Efficiency: best treatment effect, no side effect, makes the treatment more comfortable.

3.  Safety: in this beauty system, IPL and RF can be used together or separately, operator could choose the low light energy or the high radio frequency energy, that greatly reduce the risk of burn epidermis after the treatment. After this system treatment, almost no inflammation on face syndrome etc. So the patients are unnecessary to worry about burning skin in epidermis, which originating from over energy or the probe closely near skin

4.  Economical: best results, low cost of maintenance. Moreover, because of unnecessary higher IPL energy, prolong the lifetime of the handle for 2 or 3 years, which greatly reduce the cost. Easy daily maintenance, easy master after the simple training

5.  Wide range of treatments, great effect, and with high safety factors

Three:  Applications

1.  Deeply wrinkle removal and face lifting: integrating with the IPL and RF technology, deeply remove the wrinkle and lift face ( this is only for the machine with RF fuction)

2.  Unwanted hair removal: take advantage of intensive pulsed light and RF energy (could act on skin below 6 mm), directly act on the hair follicle to remove the thick dark hair, and tiny hair

3.  Pigment and vascular treatments

4.  Skin rejuvenation and breast lifting

Four:  Taboos

1.  Pregnant women

2.  Insulations in the sun

3.  Sensitive to light, medicine, or are taking medicine that sensitive to light

4.  Not representative naevi or malignant pathological changes in the treatment area

5.  Pacemaker or quiver dispelling device user

6.  Herpes or trauma

7.  Pimple record

8.  People who accept Hirudin etc. treatment (should stop using it before 2 weeks ).

9.  Severe diabetes patient, high blood pressure sufferer, and epileptic

Five:  Security introduction of the intensive pulsed light

Skin photo rejuvenation system FG 800 is high technology iatric equipment, for various face blemish elimination and redundant hair removal on body. After eligible training, it’s safe to use. Operators and assistants must know the security notice in this chapter. Most important, it’s the mostly safe design for both treatments. All are as following:

Adopt the closed filters and crystal of transferring light, and the light only emit from the probe

Independent electro circuit, automatically stop working when super energy

The red pause switch facilitates your urgency

WARNING

1.  Any intensive light without incorrect using can injure the body. In the course of working, the device will produce high pressure. So every operator should keep warning, operating according to this introduction.

2.  Patient: It’s more important that seasoned operator and appropriate disposal treatment room. Moreover, the patient should also know the treatment theory and wear the professional protective eye-patch, protecting eyes from burning.

3.  Operator: During the treatment, it’s possible to touch the intensive light. So it’s necessary to wear the 3 grade blinder.

4.  Treatment room: the room must clear mark “using intensive light”

MAIN WARNING

1.  For safe using, should carefully read the warning notice:

2.  Except the authorized mechanic, any others have no right to examine and repair the IPL setup, especially the inside of device that including electrical source, cooling system, optic organs and handle. Notice the dangerous high pressure inside.

3.  Make sure whether it’s accordant to your resident voltage or not.

4.  Maintenance must after turning off the device and drawing out the electrical source line. Or it’s most possible to injure people and damage the equipment.

5.  Keep the filter and the probe clean. Do not let the cooling gel enter into the probe

6.  Stop turning on when finding slack from handle. If turning on, please close right now.

WARNING ON INTENSIVE LIGHT

1.  The intensive light is possible burn eyes or fire. So it’s necessary to protect in any way.

2.  Over light energy could burn skin, that results in atrophy or pigment deposit.

3.  Do not directly see the intensive light or laser light during treatment, even wear the protective glasses and eye-patch.

4.  Do not point the handle to the air. Generally, hang it in the bracket. Point to the treatment areas when operating.

Six:  Security introduction of the electricity and equipment

1.  Keep close both panels and cover board.

2.  High pressure inside the equipment. It’s possible to deposit electricity in some parts after switching off. So it’s not allowed to open equipment beyond the authorized mechanics.

3.  When maintaining, please close power, cover board, and observe in person.

4.  Total weight is 40 KGs, so please take care when moving.

5.  Safe power line designed with 3 cores.

PREVENT FIRE

1.  The temperature will rise after absorbing light energy, so please take actions to reduce the flammable risk on treatment areas or around area.

2.  Do not use ethanol, acetone or other flammable things on skin before treatment. If necessary, please use soap or water.

3.  When taking off the handle or other parts in ethanol, please wait till dry.

SYSTEM SAFETY SETTINGS

1.  There are some safety settings inside equipment, so please know their places and using methods.

2.  Key: it’s used to open or close the power, only provide by our company.

3.  Imperative switch: the red switch is used to switch off power on emergency. Press it can     switch off the power right now. Wrest it clockwise, the device will be go on wording. Or the device keeps turning off.

CLASS OF EQUIPMENT

1.  Class of motor protection:1 CLASS,BF CLASS

2.  Anti-corrosive liquid: general

3.  Not allowed to use in the air mixed flammable anesthetic and nitrous oxide

4.  Operation manner: continuous operation

 

 Seven:  Operation of the controller:

1.           When turning on the device, the screen will show as the picture one:

2. Press the “IPL”, the screen shows the treatment menu, as picture two:

Pulses number

 

Parameter range:

IPL output energy:   1-50J,  it will display the value of current IPL output energy

Width of first pulse:  0.1-10.0ms, every 0.1ms per unit

Interval of 1st pulse:  1-100ms , every 1ms per unit.

Width of 2nd pulse:   0.1-10ms, every 0.1ms per unit

Interval of 2nd pulse: 1-100ms, every 1ms per unit.

Width of 3rd pulse:   0.1-5.0ms, every 0.1ms per unit

Pulses number:      3-10

Cooling:             1-5 level. Most of time on five

Frequency :          it is 2, 3 or 4s interval between 2 spot

3.Select the relevant treatment, such as skin Rejuvenation, Hair Removal, Pigment thearpy. Now take hair removal for example, adjust the parameter – picture 3, press the “standby” to “ready”

then press “ready” to “ work” enter into the treatment mode. At this time, the system will charge to “work” status, show as follows picture four:

After the status changes to “work” , you can press the button on handle to start to work.

4, setting

This program has 6 language, English, Chinese, Italian, France, Spanish, German. You can choose you want.

And you can set the time local.

Press the left up corner of the screen, and then will go into the setting page

Eight:  Clinic operation

1.  Before treatment

A:  Classification of skin: it's safe and effective to the white, brown or yellow skin.

B:  Sign the agreement

C:  Clean the skin, and eliminate the perfume and cosmetics.

D:  Use digital camera for memory, take photo from different orientations

E:  If necessary, use external anesthetic one hour before the treatment; if for the hair removal treatment, please cut the hair to 1mm before treatment.

F:  Before the treatment, please make sure enough water and water circulation inside the device, and must wait for the probe cooling then allow doing the treatments. If the probe is not cold or become hot, please stop all operation and do not use the device, avoid damaging the device.

          

2.  In the process of treatment

1.  Patients take the protective eye-patch, at the same time, the operator also wear the professional protected glasses, respirator and medical gloves.

2.  Spread approximate 3mm cooling gel in front the ears and below the chin. Making test of 2-3 spots according to the former parameter designed. After 3-5 minutes, observe the reflection of skin, to make sure the treatment parameter. However, it needs to wait for a little longer time.

3.  When taking the treatment to the protrudent parts in the bone structure (like forehead, mandible and cheekbone). Appropriately adjust the RF energy based on different conditions of patients.

4.  During the treatment, vertically slide the bipolar probe on skin with level force, and observe whether it’s touched well or not. Overlapped shoot makes sure to good effects of treatment area.

5.  In the process of treatment, continuously step the foot-touch, will result in uneven output energy. Please one press of the button on handle and one move, or step the foot-touch step by step

6.  When ending the treatment or try to change another treatment area, firstly release the button on the handle or foot-touch, avoiding electric shock by chance

7.  It’s can be adjusted the energy, according to the actual conditions of the patients.

 

3.  Notices of treatments

1.  Avoid sunlight and burn before and after treatment, could use the suntan lotion (cream) (SPF>30) to avoid direct sunshine.

2.  Avoid chemical or mechanical stimulation before and after 1 week of the treatment

3.  Do not take filled things or injection treatment before and after 2 weeks of the treatment

4.  Avoid direct or indirect heat stimulation to the treatment area after 3 days of the treatment, especially to those of high pigment deposit.

5.  If taking laser skin care treatment before this treatment, please wait for 3 weeks at least.

6.  After the treatment, patients are not allowed to eat the foods of dark color or great pungent within two weeks, such as the sauce, coke, sea foods, capsicum etc.

7.  It is not allowed insulation in the sun before and after the treatment

8.  It is not allowed that use any cosmetics after the treatment, suggested that use the natural moisturize products

9.  Please cooling the bad reaction area after the treatment with , like tumescence and causalgiase.

 Nine:  Parameters of each treatment

1.  Pigment treatment-530nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 2-3 weeks for one treatment. Because the human metabolism period is 2-3 weeks, some decomposed pigment cells are phagocytosed by the lymphocyte, and expel from body along with the metabolism.

3.  Feelings in the treatment: some pain feelings like needle pricking. 3-30 minutes after the treatment, pigment will be darker. Pigment scab will shed 3-7 days later.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment, scrape the cooling gel, or cooling with ice for 10 minutes

6.  Operating sequence: clean skin and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment. Overlapping size of spots: 1-2mm

9.  Parameters:

      1st  pulse width      2nd pulse Width     3rd pulse Width

6.5-7.5           7.0-8.0             5.0

 

                1st pulse Interval 4-7      2nd pulse interval 5-9     pulse number 3-4

2.  Hair removal treatment-640nm

1.  3-5 treatments as one cycle.

2.  Because the hair has its own growth cycle and dormant cycle, so it’s effective to remove the hair in growth cycle, 3-5 treatments.

3.  Every 2-3 weeks for one treatment. Because the human metabolism cycle is 2-3 weeks, some decomposed pigment cells of hair follicle are phagocytosed by the lymphocyte, and expel from the body along with metabolism.

4.  Feelings in the treatment: some pain feelings like needle pricking. 3-8 hours after the treatment, a little inflamed feelings on skin. Lightly tweezer the hair root, naturally sheded and no pain, which means the best effect.

5.  Effect of cooling gel: cooling and light transporting

6.  Usage: spread the cooling gel on the treatment area before treatment, around 3mm thickness; 20minutes after the treatment, scrape the cooling gel , or cooling with ice for 10 minutes

7.  Operating sequence:

Clean skin, shave the unwanted hair on the treatment area or shear the unwanted hair, 1mm to the hair root; and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment for 5-15 minutes

8.   Parameters:

      1st  pulse width      2nd pulse Width     3rd pulse Width

6.0-8.0           7.0-8.0             5.0


 

                1st pulse Interval 5-8      2nd pulse interval 6-10     pulse number 3-5

3.  Wrinkle removal treatment-530nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 2-3 weeks for one treatment. Because the human metabolism cycle is 2-3 weeks, The stimulated collagen fiber cells and flexibility fiber cells will be growing and renewing along with the metabolism.

3.  Feelings in the treatment: some pain feelings like needle pricking. Skin will be light red with some swollen feelings after treatment.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment, scrape the cooling gel, or cooling with ice for 10 minutes.

6.  Operating sequence:

Clean skin and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment. Overlapping size of spots: 1-2mm

9.  Parameters:

     1st  pulse width      2nd pulse Width     3rd pulse Width

6.0-8.0           7.0-8.0             5.0
 

                1st pulse Interval 5-8      2nd pulse interval 6-10     pulse number 3-5

4.  Skin whitening treatment-530nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 2-3 weeks for one treatment. Because the human metabolism cycle is 2-3 weeks, some decomposed pigment cells are phagocytosed by the lymphocyte, and expel from the body along with metabolism.

3.  Feelings in the treatment: Swollen feelings inside skin.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment, scrape the cooling gel, or cooling with ice for 10 minutes

6.  Operating sequence:

7.  Clean skin and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment. Overlapping size of spots: 1-2mm

8.  Parameters:

 1st  pulse width      2nd pulse Width     3rd pulse Width

6.0-8.0           7.0-8.0             5.0

 

                1st pulse Interval 5-8      2nd pulse interval 6-10     pulse number 3-5

5.  Skin rejuvenation treatment-530nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 2-3 weeks for one treatment. Because the human metabolism cycle is 2-3 weeks, the stimulated collagen fiber tissues and flexibility fiber tissues will be steady along with the metabolism.

3.  Feelings in the treatment: Swollen feelings inside skin.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment scrape the cooling gel, or cooling with ice for 10 minutes.

6.  Operating sequence:

Clean skin and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment. Overlapping size of spots: 1-2mm

g.          Parameters:

     1st  pulse width      2nd pulse Width     3rd pulse Width

6.0-8.0           6.0-8.0             5.0
 

                1st pulse Interval 5-8      2nd pulse interval 6-10     pulse number 3-5

6.  Vascular treatment-530nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 2-3 weeks for one treatment. Because the human metabolism cycle is 2-3 weeks, the stimulated capillary vessel tissues will be shrinking and steady along with the metabolism .

3.  Feelings in the treatment: some pain feelings like needle pricking. A little inflamed feelings on skin after the treatment.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment scrape the cooling gel, or cooling with ice for 10-20 minutes

6.  Operating sequence:

Clean skin and spread cooling gel on the treatment area; after the treatment, make a ice cooling treatment. Overlapping size of spots: 1-2mm

7.     Parameters:

      1st  pulse width      2nd pulse Width     3rd pulse Width

6.2-8.2           6.5-8.5             5.0
 

                1st pulse Interval 5-8      2nd pulse interval 2-4     pulse number 3-5

7.  Acne treatment-480nm

1.  1-3 or 3-6 treatments as one cycle.

2.  Every 1-2 weeks for one treatment.

3.  Feelings in the treatment: Swollen feelings inside breast.

4.  Effect of cooling gel: cooling and light transporting

5.  Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20minutes after the treatment, scrape the cooling gel

6.  Operating sequence:

Clean skin, spread some essential oil on breast and massage, then spread cooling gel on breast. No overlapping spots.

7.   Parameters:

       1st  pulse width      2nd pulse Width     3rd pulse Width

3.5-4.5           5.0-5.5            2.0
 

                1st pulse Interval 3-5      2nd pulse interval 3-5     pulse number 2

Remarks: IPL energy:

1.  Please do not press the button on handle before touching treatment area.

2.  Keep pressing the button in handle as moved it, one shot for one treatment area. At the same time, please keep the probe vertically slide on skin for each movement.

3.  When finish the treatment or try to move to another treatment area , firstly release the button on the handle or foot-touch, avoiding electric shock by chance

4.  IPL parameter in the treatment:

White skin: generally start from 15, then increase or decrease the parameter according to the actual sense of the patients

Black skin: generally start from 10, then increase or decrease the parameter according to the actual sense of the patients

Dark black skin: generally start from 10, then increase or decrease the parameter according to the actual sense of the patients

Moreover, the IPL parameter to the dark black skin treatment will be 5 lower than the value to the black skin treatment.

Above all operation must consider the actual sense of the patients.

    5. when the machine working, must make sure plug the filter into the handle tightly.

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628