Electrosurgical Generator (HV-300)
Electrosurgical Generator (HV-300)
Electrosurgical Generator (HV-300)

1 / 1

Electrosurgical Generator (HV-300)

Get Latest Price
Send Inquiry
Model No. : HV-300
Brand Name :

Product description

Product Description

HV-300 Electrosurgical Generator
 
HV-300 Electrosurgical Generator
Versatility in office-based Electrosurgery
For general electrosurgery needs in the office, clinics, or emergency room, the HV-300 generator provides exceptional performance, reliability, and safety benefits in a compact, easy to use unit.
 
Ease
Ease and quick to set up; compact and light
Save time with automatic access to previous used power settings and modes
Provides precise surgical effect with power control dials
 
Flexibility
Performs most common office-based electrosurgical procedures
Includes both monopolar and bipolar outputs
 
Reliability
Manufactured to the highest standards of quality in electrosurgical technology
Ensure consistent clinical performance over a variety of procedures
 
Safety
Increased patient safety with a return electrode contact quality monitoring system (REM). The REM system continually monitors patient impedance levels and deactivates the generator if a fault in the patient/return electrode contact is detected.
 
High Frequency leakage
Bipolar: less than 60mA
Monopolar: less than 150mA
 
Low frequency leakage
Source current, patient leads, all outputs tied together
Normal polarity, intact chassis ground <10uA
Normal polarity, ground open <50uA
Reverse polarity, ground open <50uA
Sink current, 140V applied, all inputs <50uA
 
Power readouts
Agree with actual power into rated to within ±20% or 5W, whichever is greater, Dossage Error monitor.
 
 
Unique features of the HV-300 Electrosurgical Generator
Improved performance at lower power settings minimizes the risks of tissue damage and neuromuscular stimulation
Easy to use, cost effective system when performance is required and price is of equal concern
 
Two cut modes offer surgeons a variety of choices:
Pure cut for a clean, precise cut
Blend for cutting with hemostasis
 
Two Coag modes:
Fulgurate for lower voltage coagulation requirements
Spray for coagulating large tissue areas with superficial of necrosis
 
Standard bipolar mode
Standard mode utilizes low voltage to prevent sparking
 
Versatile system that is uniquely compatible with other, including:
TUR UNDER WATER CUT (ENDO cut socket)
HV argon congulation system
Optimumm Smoke Evacuation System-Clean air in the operation theatre
 
Technical Specifications
Output Frequency 540Khz
Line Voltage: 110V/220V~
Line Frequency 50/60Kz
 
Weight and Dimensions
Height: 14cm
Width: 32cm
Length: 41cm
Weight: <8.5kgs
 
Applicable range
Applicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery, microsurgery, ENT surgery and etc.
 
Output Characteristics

Mode Maximum
P-P Voltage
Rated Load
(OHMS)
Maximum
Power (Watts)
Crest Factor
(Typical)
Bipolar Standard Coag 550 100 70 1.6
Monopolar Cut Pure 1900 300 300 1.6
Blend 2300 300 250 2.5
Monopolar Coag Fulgurat 2800 300 120 2.9
Spray 7000 300 100 6.2