Model No. : | SC202G 2-Wire Conductivity/Resistivity Analyzer |
---|---|
Brand Name : | Yokogawa |
Product description
* | Universal conductivity/resistivity, software switchable. |
* | On-line sensor checking. |
* | Event logbook in software. |
* | Matrix temperature compensation for pure water applications. |
* | Password protection for all levels of software. |
* | Easy to use EXA control panel. |
* | Pharmaceutical pure water monitoring (USP<645> as issued in ed. 23.). |
* | HART®, PROFIBUS-PA, FOUNDATION Fieldbus H1 communications. |
Input specifications | Two or four electrode measurement with square wave excitation. Cell constant from 0.008 to 50.0 cm-1 |
Detection method | Frequency, read-pulse position and reference voltage are dynamically optimized. |
Input ranges | Conductivity: Minimum: 0 μS/cm Maximum: 200 mS x C (overrange 1999 mS/cm). Resistivity: Minimum: 0.005 kΩ/C Maximum: 999 MΩ x cm Temperature: Pt1000: -20 to 250°C (0 to 500°F) Pt100 and Ni100: -20 to 200°C (0 to 400deg F) 8k55 NTC: -10 to 120°C (10 to 250°F) PB36 NTC: -20 to 120°C (0 to 250°F) |
Output Span | Conductivity: Min. 0.01 μS/cm, Max. 1999 mS/cm. (Max 90 % zero suppression) Resistivity: Min. 0.001 kΩ x cm, Max. 999 MΩ x cm. (Max 90 % zero suppression) |
Transmission Signals | Isolated output of 4 to 20 mA DC. Burn up (21 mA) or Burn down (3.6 mA when HART or distributor comm. is non-used, 3.9 mA when HART or distributor comm. is used) or pulse of 21 mA to signal failure. |
Temperature compensation | Automatic, for temperature ranges Reference temp.: programmable from 0 to 100°C or 30 to 210°F (default 25°C). |
Compensation algorithm | NaCl: According IEC60746-3 NaCl tables (default). T.C: Two independent user programmable temperature coefficients, from 0 to 3.5 % per°C (°F) by adjustment or calibration. Matrix: Conductivity function of concentration and temperature. Choice out of 5 preprogrammed matrices and a 25-point user programmable matrix. |
Communications | HART®, PROFIBUS-PA, FOUNDATION Fieldbus H1 |
Ambient temperature | -10 to 50°C |
Humidity | 10 to 90 % RH (Non-condensing) |
Display | Custom liquid crystal display, with a main display of 3 1/2 digits 12.5 mm high. |
Power supply | Nominal 24 volt DC loop powered system. SC202G: 17 to 40 V SC202S: 17 to 31.5 V |
Conductivity | Accuracy: ±0.5 % F.S. (2 μS x K cm-1 to 200 mS x K cm-1) |
Resistivity | Accuracy: ±0.5 % F.S. (0.005 kΩ/K cm-1 to 0.5 MΩ/K cm-1) |
Temperature | Accuracy: ±0.3°C (Pt1000, PB36NTC, Ni100) |
Step responce | 90 % (<2 decades) in 7 seconds |