1 / 2
Brand Name : | FULONG |
---|---|
Working Pressure : | Low Pressure Pump |
Product description
WQ series submersible sewage pump own the new patented technology and design. It specialized design for construction site, municipal industry, public services and industry`s sewage treatment. As requirement, the pump can configurate kinds of signal transducer, for monitoring pumps working condition.
It can continuous working only the impeller into the water, and the whole motor above water. In any condition, the pumps can work well and easy repair.
WQ submersible sewage pump efficiency non-clog submersible sewage pump is on the basis of the introduction of foreign advanced technology, combining with the characteristics of the use of domestic water pump and the successful development of a new generation of pump products, energy saving effect is remarkable, winding, no jam, automatic installation and automatic control, etc. Solid particles in the lining and long fiber waste, has a unique effect.
Product Features:
1. the use of a unique single or double blade impeller structure,
greatly improving the dirt through capacity, can effectively through the
pump diameter of 5 times the fiber material and diameter of the pump
diameter of about 50% of the solid particles.
2. the mechanical seal using a new type of hard corrosion-resistant
titanium tungsten material, the pump can run safely for more than 8000
hours.
3. the overall compact, small size, low noise, energy-saving effect is
remarkable, easy maintenance, no need to build pump house, diving into
the water to work, greatly reducing the project cost.
4. the pump sealed oil chamber is equipped with high-precision
anti-jamming leakage detection sensors, stator windings embedded in the
thermal components, automatic protection of the pump motor.
5. according to the needs of users with automatic control cabinet, the
pump leakage, leakage, overload and over-temperature, such as automatic
protection to improve product safety and reliability.
6. the float switch can change according to the required level,
automatic control of the pump start and stop, without special care, the
use of extremely convenient.
7. WQ series can be equipped with dual-rail automatic coupling
installation system, which brings more convenience to installation and
maintenance, so that people do not need to enter the sewage pit for this
purpose.
8. can be used in the whole head, and ensure that the motor is not overloaded.
9. there are two different installation methods, fixed automatic coupling installation system, mobile free installation system.
The main parameters
Model
Item
Head Range /m
Pump
Efficiency/%
Rated Power/KW
Rated Current/A
Motor
Efficiency/%
WQ18-15-1.5
18
15
2840
1.5
47.1
WQ15-22-2.2
15
22
2840
2.2
50
WQ50-10-3
50
10
1430
3
54.5
WQ24-20-4
24
20
1440
4
49
WQ40-15-4
40
15
1440
4
54
WQ65-15-5.5
65
15
1440
5.5
56
The main purpose:
WQ
sewage submersible pump is mainly used in chemical, petroleum,
pharmaceutical, mining, paper industry, cement plant, steel plant, power
plant, coal processing industry, and urban sewage treatment plant
drainage system, municipal engineering, construction sites and other
industries conveyor belt Granules, sewage, dirt,
can also be used to pumping water and corrosive media with high
efficiency, energy saving, anti-winding, no clogging, high reliability. The flow range of 15-100 cubic meters / hour, the lift range of 10-50 meters.
Precautions:
1.
If the pump is used to suck thicker than the viscosity of the slurry,
the need to clean the pump chamber to prevent the pump to leave
sediment.
2. Do not lift or suspend the cable.
3. The pump should not be long-term low-lift operation in the state, to prevent overload and burn out the motor.
4.
When the customer is equipped with automatic coupling device, the
length of guide rail should be determined (standard length is 3M).
5.
Under normal conditions, every 300-500 hours should be added or
replaced oil in the oil room (10-30 # oil), to improve the service life
of mechanical seals. Pump routine operation after
3000 hours, the need for the pump for inspection and maintenance, if
necessary, replace the wearing parts should not be reused.
Conditions of Use:
Medium temperature does not exceed 60 ℃, the severity of 1.0 ~ 1.3kg / dm3, PH value in the range of 5 to 9. The pump is mainly made of cast iron and can not be used for pumping highly corrosive liquids. Pump
work, the motor part of the exposed surface shall not exceed 1 /
2.1Cr18Ni9Ti stainless steel can use a variety of corrosive media.
Send your inquiry to this supplier