1 / 1
Model No. : | RS-LF6A |
---|---|
Brand Name : | Risingsun or OEM |
Condition : | New |
Product description
Water Cooled Industrial Screw Refrigerator Chiller
Description of the Open Type Screw Chillers,
Open Type Industrial Water Chiller is with following features,
· Temperature range 5~35°C.
· All adopt imported compressor : piston & scroll type are optional.
· Tube-in-shell water cooled condenser with excellent heat transfer and rapid cooling.
· Adopts SUS made insulated water tank
· R22 refrigerant is used as standard & optional R407 for efficient cooling.
Parts of the Water Chillers,
Specification of the Open Type Screw Chillers,
Model
Unit
RS-LF1A
RS-LF2A
RS-L3W
RS-L5W
RS-L6W
RS-L8W
RS-L10W
RS-LF3A
RS-LF5A
RS-LF6A
RS-LF8A
RS-LF10A
Capacity
KW
2.77
5.28
7.91
12.9
15.22
23.8
30.5
Kcal/h
2382
4541
6803
11094
13091
20468
26230
Compressor
Input power
KW
0.89
1.77
2.8
4.5
5.2
3x2
4.5x2
Related power
HP
1
2
3
5
6
4x2
5x2
Power
1 Phase-220V/50HZ
3 phase-380V/50HZ(200V/220V/415V 50HZ/60HZ)
Evaporator
Type
Water Tank with Coil(Shell and Tube)
Pipe diameter
inch
6'
6'
1"
1"
1"
2"
2"
Refrigerant
Type
R22
Quantity
kg
1.6
1.8
2
2
2.5
4
5
Water Condenser
Type
Pipe diameter
inch
1"
1"
1"
2"
2"
Cooling Water Flow
m3/h
0.476
0.908
1.36
2.22
2.6
3.95
4.42
Air Condenser
Type
Finned copper tube+ Low noise outer rotor fan
Fan power
W
85x1
85x1
135x1
135x2
135x2
420x2
420x2
Water tank capacity
Liter
20
20
50
60
60
110
110
Pump
Power
KW
0.37
0.37
0.37
0.37
0.75
0.75
0.75
HP
0.5
0.5
0.5
0.5
1
1
1
Distance
m
23
23
23
23
35
13
13
Flow Rate
L/min
100
100
100
100
110
200
200
Safty Protection
High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc.
Dimensions (L*W*H)
Water Cooled
mm
935*500* 883
935*500* 883
935*500* 883
1270*650
*1413
1270*650
*1413
Air Cooled
mm
800*490* 898
795*566* 1058
960*630* 1073
1280*630* 1118
1280*630* 1118
1550*830* 1543
1550*830* 1543
Note: Voltage: 3⊙,380V,60Hz;
Note: 1.Cooling Capacity is calculated based on: inlet/outlet chilled fluid temperature:12℃/7℃,inlet/outlet cooling water temperature:30℃/35℃.
2.Working condition: Chilled fluid temperature: from 5℃ to 35℃. Inlet/outlet chilled fluid Temperature difference: from 3℃ to 8℃
Cooling water temperature: from 18℃ to 37℃, Inlet/outlet cooling water Temperature difference: from 3.5℃ to 10℃.
We reserve the right to modify above information without prior notice.
Working Principle of the Water Chillers,
OEM Service of the Water Chiller,
Send your inquiry to this supplier