1 / 1
Model No. : | EST-40 |
---|---|
Brand Name : | EIDISON |
Product description
Model Specification | T-40A | T-40B | T-40C | ||||||
CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC output voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V |
Output voltage error (Note2) | 2% | 6% | 8% | 2% | 6% | 8% | 2% | 6% | 8% |
Rated output current | 3A | 2A | 0.5A | 3A | 2A | 0.5A | 3A | 1.5A | 0.5A |
Output current rage | 0.6-5A | 0.2-3A | 0.1-1A | 0.6-5A | 0.2-3A | 0.1-1A | 0.6-5A | 0.2-2A | 0.1-1A |
Wave and noise(Note3) | 100mVp-p | 120mVp-p | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 120mVp-p |
Inlet stability(Note4) | 0.5% | 1% | 1% | 0.5% | 1% | 1% | 0.5% | 1% | 1% |
Load stability(Note5) | 0.5% | 4% | 6% | 0.5% | 4% | 6% | 0.5% | 4% | 6% |
DC output power | 41.5W | 45W | 45W | ||||||
Efficiency | 72%/115VAC | 72%/115VAC | 72%/115VAC | ||||||
Adjustable range for DC voltage | CH1+10,-5% | CH1+10,-5% | CH1+10,-5% | ||||||
AC input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz;120~370VDC | ||||||||
Input current | 1.2A/115V 0.7A/230V | ||||||||
AC impulse current | Cold-start current 20A/115V 460A/230V | ||||||||
Leakage current | <3.5A/240VAC | ||||||||
Overload protection | 105%~150% Type:PULSING HICCUP SHUTDOWN Reset. auto recovery | ||||||||
Over-voltage protection | CH1:5.75~6.75V | ||||||||
High-temperature protection | …… | ||||||||
Temperature coefficient | 0.03%°C(0~50°C) ON+5V OUTPUT | ||||||||
Setup rise hold up time | 1.6s,50ms,16ms/115VAC 800ms,50ms,60ms/230VAC | ||||||||
Vibration | 10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes | ||||||||
Withstand voltage | Input and output interval:3KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | ||||||||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms | ||||||||
Working temperature and humidity | -10°C~+60°C,20%~90%RH | ||||||||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | ||||||||
Overall dimension | 129*98*38mm | ||||||||
Weight | 0.45Kgs | ||||||||
Safety standards | Meet CSA950,UL1950,IEC950,EN60950 | ||||||||
EMC standards | Meet CISPR22,EN5502,IEC801-2,3,4.IEC555-2 | ||||||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity |