Towline cable Super FLEX Shielding Control cable
Towline cable Super FLEX Shielding Control cable
Towline cable Super FLEX Shielding Control cable

1 / 1

Towline cable Super FLEX Shielding Control cable

$1.00 ~ $1.00 / Bag/Bags
Send Inquiry
Model No. :
Brand Name : Shinegoo
Type : Insulated
Conductor Type : Stranded
Application : Heating
Conductor Material : Copper
Sheath Material : PVC
Insulation Material : PVC
Material Shape : Round Wire
Range of Application : LSOH
Certification : ISO9001
Brand : QIFAN
Rated Voltage : 450/750v
Working Temperature : 90℃
More
8yrs

Weifang, Shandong, China

Visit The Store

Product description

Towline cable Super FLEX Shielding Control plastic cable drag chain

High quality PVC insulated control cable


APPLICATIONS:

It is the control cable being used for cranes and other appliances in dry or wet environment (indoor). For its special flexibility, it also can be used for non-continous installation or fixation, but can not work as elevator cables. Just insulated cable rope among cores functions as tensile resistance, There is non-woven fabric to release impact between cores and sheath.

 

STRUCTURE:

Conductor: Fine strands of oxygen-free copper wire.

          acc. to VDE0295, class5

Color: varous colour cores with number acc. to JISC3306

           black with white number and green/yellow acc. to IEC227

Inner liner: non-woven fabric wrapping to release impact

 

Steel rope: One or two self-supporting steel rope is used to carry tensile force in working.

 

Outer sheath: special PVC, bkack (RAL9005)

 

TECHNICAL PARAMETERS:

Voltage Rating: 300/500V

Test Voltage: 4000V

• The temperature range:

       fixed: -40℃ to +70℃
       Deflection: -5℃ to +70℃
• Bending radius:

   flxed: 6XD

   Deflection: 10XD

 Insulation resistance: 20 MΩ x km

 

Standard and Approval

 VDE 0245, VDE 0812, CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

U0~Valid value of the voltage between main insulated conductor and earthing (metal shield, metal sheath of environment dielectric).

U~valid value of voltage between any two phases conductor in multicourse cable or single core cable system.

When AC. System is applied, the rated voltage of cables should be at least equal to the nominal voltage of the system. When DC. System is applied; the nominal voltage of this system should not be more than the rated voltage of the system by 1.5 times.

 

The permitting long-term operating temperature of cable conductor should be

PVC insulation: 70

Chemical Sioplascable: 90

Irradiation XLPE :105~135

 

The installing temperature of cable should not be less than 0.

Recommending permitted bending radius:

Non-armored cable: not less than the overall diameter f cable by 6 times

Shielded flexible cable: not less than the overall diameter of cable by 6 times


Our Factory

power cable factory (1)


Detailed Product Description

1.Standard

The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

2.Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

3.Type& Specification

Type

Name

Section Area(mm2)

No. of Core

Application Site

KVV

Copper Conductor,PVC Insulated and Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KVVP

Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KVVP2

Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable

0.75 1.0 1.5 2.5

4-10

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

7-61

10

4-10

KVV22

Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

4 6

4-14

10

4-14

KVVR

Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KVVRP

Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable

0.5 0.75 1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

KYJV

Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KYJVP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KYJV22

Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force

4 6

4-14

10

4-10

KYJVP2

Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

4-14

10

4-10

KYJVR

Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KYJVRP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable

0.5 0.75 1.0

4-61

 Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

4.Service Conditions

(1) The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

(2)  The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D

The main feature of flame retardant control cable is hard to get fire or the continuous burning of wire is very limited when it is on fire. It applies to the place where higher demands of flame retardance.

factory (7)



Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628