1 / 1
Model No. : | DTSD450 15/60A 3*230/400V |
---|
Product description
Display | LCD |
---|---|
Color | transparent |
function | anti tamper |
Voltage | 120/240v |
Connection adapt | RS485/RS232 |
Reference Voltage | 200V |
Operating Temperature | 20~80 degree |
Measuring Electricity Range | 1A~100A |
Maximum Current | >10A |
Class Of Accuracy | 0.3-0.5 |
Display Mode | Analog & Digital |
Phase | Three Phase |
Material | Steel |
Output Voltage | 120V~240V |
Item | Specification | Data | Manufacturer data |
1 | Voltage | Operating voltage 380v+15%-20% | 323v-456v |
2 | Current | Direct connection or indirect connection with current transformer (Ibase/Imax)5/100Amp | 5/100A |
3 | Measuring connection | Kwh max demand in Amp ,current in Amp voltage in volt for each phase | Yes |
4 | connection | 4 wire direct connection or through current transformer | 3phase 4 wire |
5 | Frequency | 50Hz/sec +/- 2% | 50/60Hz |
6 | Accuracy class | 0.5for kwh | Class 0.5 |
7 | display | Display screen Liquid crystal lcd display is retained during loss of power 8digits at least without fraction ,display area not less than 20mm2 for each digit The registers shall auto reset to zero after they have reached their max Indication 99999999&a specified digit for indicating the no of reset cycles (in case of 8 digits only ) Values to be displayed Total consumption in kwh Max demand in amp |
8 digital LCD Values to be displayed Total consumption in kwh Max demand in amp |
8 | Energy consumption | Not more than 2watt | 2w 10va |
9 | Relative humidity | From 0-90% at least | 0-90% |
10 | Temperature range | From -5 to 70 degree for components inside the meter up to 80 degree | 0-80 degree |
11 | Degree of portection | IP51 IP54 for coastal &moist regions (according to each “EDC”requirment) |
IP54 |
12 | Other annunciation on lcd screen | Voltage value in V for each phase Current value in A for each phase Opened sequence monitaoring (blinking in case of reverse phase sequence ) In case of missing voltage in one phase |
LCD will show each phase voltage Each phase current Kwh ,times |
13 | LED indications | An indicating LED saprkles red with frequency according to the consumption rate it is used for calibration &operation indication An indicating LED sparkles yellow at opened cover or at tamper events in meter connection ,it can be turned off only through the EDC” |
4 LED light One LED show kwh ,one show kvarh Red infrared led Alarm led |
14 | No of sealing | Top cover :2 Terminal box :1 |
Seal for top cover 3 Seal for teminal box 2 |
15 | Meter current snecors | The meter shall have current sensor mounted on both phase &neutral due to which it registers the energy consumption correctly even if is tampered by the following methods Reversal of input &output terminal of meter The load is partially or fully drawn through external earth (in case of direct connection only ) Phase voltage loss in one or two phases (in case of direct &indirect connection ) |
Yes |
16 | Memory data time | The meter stores the reading &data in a nonvalatile permanent memory which saves the registered data even in case of power failure ,the storage period should not be less than the meter life times (10years ) | 10 years |
17 | LCD Life | The life time of the screen is not less than the life time of the meter | Years |
18 | Pushing button | The meter face should be equipped with a push button to wake up the display screen from sleep mode to read data only if needed ,so as to save the LCD life time | There on pushing button control the LCD life |
19 | Battery life | The meter must contain a super capacitor as a source of power in case of power failure to indicate the data of consumption by pressing the push botton ,the supper capacitor saves the charge for at least 48 hours so that the data can be read 5 times with period of indication on LCD not less than 30 seconds | Battery life can charge for at least 48 hours ,then press pushing botton ,it will save |
20 | IEC 61107 standard | Connunictation with meter is done according to IEC61107 Through a suitable communication port on the front of the meter ,which is used to retrieve data registeered in the meter memory or to modify data on meter without opening the cover or terminal cover | |
21 | Nameplate making detail | The nameplate must contain all technical data as : Year of manufacture ,serial no ,accuracy class ,frequency voltage ,current ,no of puls /kwh ,name of edc name of manufacturing company The data should be printed on the name plate and secured against removal ,the serial no written on the nameplate must be the same as the serial no saved in the meter memory and is indelible |
Show all the demanding data in the nameplate |
22 | Diagram of terminal | The terminal cover must have an indelible drawing to indicate the method of connection of the meter | Yes |
23 | Connection point | The connection point between the voltage and the input current inside the meter shold be by joint screw not welded | Yes |
24 | Standard IEC62052-11 | IEC62052-11 |
Payment Terms | L/C, T/T, D/A, D/P, Credit Card, Western Union, Money Order, Paypal, Others |
---|---|
Minimum Order | 5PCS |
Lead Time / Delivery Time | 10 Day(s) |
Sample Available | YES |
Delivery Details | 1. sample will finish within 3 days 2.100pcs will finish 10days 3.10000pcs will finish 25 days payment : 30% TT in advance ,the balance will send before getting theoriginal bill of landing |
FOB Port | Beihai,Dalian,Foshan,Fuzhou,Gaoxiong,Guangzhou,Haikou,Hong Kong,Huangpu,Jiangmen,Jilong,Lianyungang,Macao,Nanjing,Nansha,Ningbo,Qingdao,Qinhuangdao,Shanghai,Shantou,Shanwei,Shekou,Shenzhen,Taibei,Tianjin,Wenzhou,Xiamen,Yantai,Yantian,Zhanjiang,Zhongshan,Zhuhai |
Loading Info | the sample will send by air ,it will quickly the bulk goods will send by sea ,we accept to FOB price ,you will indicate your agent ,or CIF price ,we give you good service |
Packing Info | 1.10pcs/45*45*35cm/15kgs/one ctn 2.inside pakcage with SILICA let goods be dry ,when the goods on the sea 3.outside take good package with two side belt |
Target Market(s) | Africa(except Middle East), Eastern Europe, Hong Kong/ Macao/ Taiwan, Japan & Korea, Latin America, Mainland China, Middle East, North America, Northern Europe, Oceania, Central & Southern Asia, Southeast Asia, Western & Southern Europe |