SNV-EKL4 Earth fault and short circuit indicator

Type: surface mounted

Optional:  

1. SNV-EKL4, normal type without RS485 and outside AC220V input.

2) SNV-EKL4, communication type, with RS485 ,Modbus protocol,and with AC220V power input.

 

Description

 SNV-EKL4 short circuit and earth fault indicator, it Widely used in various ring cabinets, high-voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid. The use of cable type short circuit and grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction, photoelectric conversion, signal optical fiber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.

Equipped with fault remote transmission port, suitable for distribution network automation;  Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the whole machine is easy to load and unload.

TYXLW9})1Z31RD05DJFNDX7



 

Function character

1) Intelligent detection of short-circuit and ground fault and through the corresponding LED on the panel to indicate fault.

2Monitor panel designed with button, it is convenient for reset or test.

3The pulse width time of fault current can be set to prevent incorrect fault indication caused by surge current.

4It can reset and detect the remote fault indication device remotely.

5It can provide switch volume for external devices through remote contact.

6It can choose the reset time after fault happen (when purchase, it need to tell factory to set,default 8hours).

7Remote fault indicating can be made by external lamp.

8It can choose the short circuit alarm current (when purchase, it need to tell factory to set).

9Earth fault alarm current set in factory

10Low battery display and alarm through press the “Test/reset” key by 3seconds.

 

Function description

1) short circuit alarm indicating: when short circuit sensor detected a short circuit fault current, and the current is bigger than equal to or equal to the setting value, then the short circuit sensor send alarm optical signal to monitor panel through optical fiber. And the monitor will display the alarm signal, the short circuit fault LED will be blinking.

2) Earth fault alarm indicating:  when the earth fault sensor detected an earth fault current, and the current is bigger than equal to or equal to the setting value, then the earth fault sensor send alarm optical signal to monitor panel through optical fiber. And the monitor will display the alarm signal, at same time, the earth fault LED will be blinking.

3) Battery low voltage alarm indicating: the monitor use the battery to supply power. When we press the “Test” button,3seconds time: If the battery voltage is lower than the min. working voltage 2.7V, then the Battery Level Led will be blinking 5 times; If battery voltage is normal, then only blink 1 times.

4)Automatic reset:  After the indicator alarm the fault, if there are without manual reset it, when the time reach our reset time setting, indicator will automatically reset.

5) Manual reset:  After the indicator alarm the fault, user can press the button “ reset/test” in a short time to reset it.

6)Remote reset: Through short connecting of the pin 3,4 back of the monitor, then the indicator will be reset.

7) Remote test: through short connect the pin 1,2, then indicator will be run the test process, and Led will be blinking.

8)Remote indicating:  Through connect the pin 7,8 to the external lamp , then it will be indicate fault when any phase alarm fault. 

9) Communication RS485 port:  Through pin 5,6, there are RS485 port, it can be remote communication to SCADA system by Mod bus protocol. This is the optional function, default as, without this function.

10) Outside power input(Pin15-16): the power grade is AC100-264V or DC110-350V. This is the optional function, only need it when use RS485 to integrate with SCADA system.

 

 

Technology parameter

Voltage grade

3-40.5KV

 

Battery life

8 year

Frequency

50HZ/60HZ

Low voltage alarm of battery

2.7V

Short circuit alarm current

150A~1200A

Short circuit sensor fiber length

3meter, or customized

Earth fault alarm current

20A~100A

Earth fault sensor cable length

3meter,or customized

Alarm current accuracy

±10%

Load fluctuation and escape pulse time setting

Short circuit

40ms,60ms,80ms,160ms

(settable)

Rated frequency withstand voltage

2KV/1min

Earth fault

Relay contact capacity

95W

work environment

Temperature

-40℃~+60℃

Reset time

settable

4H/8H/24/36H

Humidity

≤95%RH

Working power

ER17505

battery

3.6V/3500mAh

Use for cable diameter

Short circuit CTFiber, Type S

A

Ф20mm~40mm,

Normally

B

Ф300mm~70mm customized

Working current

Standby state

10μA

Earth fault sensor(Cable, type E)

A

Ф60mm~100mm

Normally

Working state

1mA

Indicator protection level

Monitor panel

IP 40

B

Ф80mm~130mm

Customized

Sensor CT

IP 65

 