Single phase AC current and voltage transducer
Single phase AC current and voltage transducer
Single phase AC current and voltage transducer
Single phase AC current and voltage transducer

1 / 2

Single phase AC current and voltage transducer

$200.00 ~ $300.00 / Set/Sets
Send Inquiry
Model No. : FUD-I/U
Brand Name : gfuve
Standard GB/T 13850-1998, IEC688:1992 : Accuracy 0.2%, 0.5%
Consumption ≤3VA : Accuracy Drift Annual Variation < 0.2%
Insulation Voltage AC 2kV/min.1mA (Between Input- Output / Power) : Insulation Resistance ≥20MΩ (DC500V)
Surge Voltage 5KV (Peak Value), 1.2/50μs : Response Time ≤350ms
Input Range AC 0-10A ,AC 0-500V(Option), 50/60Hz : Absorbed Power <0.5VA/450V, <0.2VA/100V, <0.1VA/5A
Overload Current: 2 Times Continuous, 30 Times /1s; Voltage: 2 Times Continuous : Load Resistance Current Output: RL≤550Ω Voltage Output: RL≥2kΩ
More
10yrs

Beijing, Beijing, China

Visit The Store
  • Platform Certification

Product description

Single Phase AC Current / Voltage Transducer


Function & Feature

Transforms the measured AC current/voltage to the DC current/voltage output according to the linear scale

Excellent temperature characteristic and good working stability

Configuration compactness and briefness


Model Description


FUD-Type-Input-Power Supply-Output

Type

I: Single Phase AC Current Transducer

U: Single Phase AC Voltage Transducer

Ir: Single Phase AC Real RMS Current Transducer

Ur: Single Phase AC Real RMS Voltage Transducer

AC Input

A1: 0~1A, A2: 0~5A, A3: 0~10A.

V0: 0~70V, V1: 0~120V, V2: 0~250V,

V3: 0~300V, V4: 0~450V, V5: 0~500V.

Power Supply

P1: AC110V±10%, P2: AC220V±15%,

P3: AC110V~330V.

DC Output

O1: 0~5V, O2: 1~5V, O3: 0~20mA,

O4: 4~20mA, O5: RS485.

Example 1: FUD-I-A2-P2-O4

FUD Series Single Phase AC Current Transducer

Input: AC0~5A

Power Supply: AC220V±15%

Output: DC4~20mA

Example 2: FUD-Ur-V3-P2-O4

Details: FUD Series Single Phase AC Real RMS Voltage Transducer

Input: AC 0~300V

Power Supply: AC220V±15%

Output: DC4~20mA

Please check the Type, Input range, Output range and Power supply at your order.


Technical Index


Standard

GB/T 13850-1998, IEC688:1992

Accuracy

0.2%, 0.5%

Consumption

≤3VA

Accutacy drift

Annual Variation < 0.2%

Insulation Voltage

AC 2kV/min.1mA (Between Input ~ Output / Power)

Insulation Resistance

≥20MΩ (DC500V)

Surge voltage

5KV (Peak Value), 1.2/50μs

Response Time

≤350ms

Input Range

AC 0~10A ,AC 0~500V(Optional), 50/60Hz

Absorbed Power

<0.5VA/450V, <0.2VA/100V, <0.1VA/5A

Overload

Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous

Load Resistance

Current output: RL≤550Ω

Voltage output: RL≥2kΩ

Working environment

Temperature: -10~50℃

RH: 20~90%, Without condensation

Storage conditions

Temperature: -40~70℃

RH: 20~95%, Without condensation

Installation

35mm DIN Sliding-way or M4 screws

Dimension

55mm×75mm×120mm



Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628