Model No. : ES-1000
Brand Name : EIDISON

Product description

Specifications 1.Switching mode power supply

2.AC input power suitable for the world

3.High efficiency and low operation temperature

Single Output Switching Power Supply, S-1000, 1000W  

Model

Specification

S-1000-12

S-1000-15

S-1000-24

S-1000-27

S-1000-48

DC output voltage

12V

15V

24V

27V

48V

Output voltage error (Note2)

1%

1%

1%

1%

1%

Rated output current

80A

66A

40A

37A

20A

Output current rage

0-80A

0-66A

0-40A

0-37A

0-20A

Wave and noise(Note3)

150mVp-p

150mVp-p

240mVp-p

270mVp-p

480mVp-p

Inlet stability(Note4)

0.5%

0.5%

0.5%

0.5%

0.5%

Load stability(Note5)

0.5%

0.5%

0.5%

0.5%

0.5%

DC output power

1000W

1000W

1000W

1000W

1000W

Efficiency

80%

81%

85.5%

86.5%

87%

Adjustable range for DC voltage

10%

10%

10%

10%

10%

AC input voltage range

190~240VAC 47~63Hz

Input current

8A/230V

AC impulse current

75A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~150%TypeTOLDBACK Reset auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

0.03%°C(0~50°C)

Setup rise hold up time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval1.5KvAC Input and enclosure1.5KvAC Output and enclosure0.5KvAC

Isolation resistance

Input and output intervalInput and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10°C~+60°C,20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95RH

Overall dimension

291*132*68mm

Weight

2.35Kgs

Safety standards

UL1012 TUV 60950(IEC950,UL1950)

EMC standards

CLSPR22(55022),IEC801-2,3,4,IEC555-2

Note1.The testing condition for the parameter above is230VAC input, rated load,25°C 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note5)
3.Wave testadopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test The load is from 0% to 100%,others 60%.