1 / 1
Model No. : | Lo-tube gas and the brake cable helix 7 |
---|
Product description
Item | technical parameters
| test equipment
| Sample 1 | Sample 2 | judge
| |
hardness A | 64±5 | JXM-A sclerometer | 66 | 65 | qualified
| |
adhesion strength KN/ m | ≥1.2 | JSL Electronic tension tester | 3.0 | 3.0 | qualified
| |
tensile strength MPa | ≥8 | JSL Electronic tension tester | 26 | 25 | qualified
| |
elongation at break % | ≥300 | JSL Electronic tension tester | 535 | 540 | qualified
| |
air aging 110°C×72h | Tensile strength rate % | ±25 below
| JSL Electronic tension tester | 16 | 17 | qualified
|
Elongation at failure rate% | -30~+10 | JSL Electronic tension tester | -18 | -16 | qualified
| |
variation in hardness A | ≤20 | JXM-A sclerometer | 6 | 7 | qualified
| |
brittleness temperature°C | ≤-30 | incubator
| -39 | -37 | qualified
| |
Blasting pressure MPa | ≥0.3 | air compressor
| 2.5 | 2.6 | qualified
| |
Test pressure 0.1MpaOutside diameterrate % | ≤15 | air compressor
| 8 | 8 | qualified |
Send your inquiry to this supplier