Shielding control computer cable
Shielding control computer cable
Shielding control computer cable
Shielding control computer cable
Shielding control computer cable
Shielding control computer cable
Shielding control computer cable

1 / 5

Shielding control computer cable

Get Latest Price
Send Inquiry
Model No. : DJYPVR
Brand Name : SINYU

Product description

Specifications 1.low capacitance

2.low inductance

3.distributed type instrument signal cable of perfect shield

4.anti-interference performa

Shielding control computer cable  Product introduction: The product is low capacitance, low inductance, distributed type instrument signal cable of perfect shield and anti-interference performance, it can reliably transmit feeble analog signal and digital signal, and its explosion-proof safety is prominently better than general DCS cable and control cable. The product is widely used to transmit auto-control signals in the places where exist explosion danger such as chemical, power, coal gas engineering and mine, etc, or other places where require higher explosion-proof safety.   Executive Standard      Q/AHXYLY02-2009 equivalent to British standard BS5308     Operational Performances   1. Rated AC voltage: U0/U 300/500V   2. Max. working temperature of conductor core: 70°C, 105°Cand 135°C   3. Lowest ambient temperature: for fixed laying:-40°C,non-fixed laying:-20°C   4. Allowed minimum bending radius of cable: for non-armored cable, not less than 6 times of cable outer diameter; for copper tape shield or annoyed cable, not less than 12 times of cable outer diameter.   Main Technical Data

Item

Unit

Data

Working capacitance

PF/m

≤80

Capacitance unbalance

PF/m

≤1

Distributed inductance

µH/m

≤0.6

Inductance/resistance

µH/Ω

≤25

Induction voltage (interference magnetic field 400A/m)

mV

≤5

Static induction voltage (static voltage 20kV)

V

≤1

Radiation field penetration (interference field 200MHz, 120dB)

dB

≤66

Insulation resistance at 20°C

MΩ.km

≥5000

Test voltage

V/1min

2000

Flame-retardant character (test to be performed in terms of GB/T12666.5-1990)

 

Type A

  Basic Types and Descriptions  

Type

Designation

IAJYPVP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS cable

IAJYPVRP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP1VP1

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield, intrinsically safe DCS cable

IAJYP1VRP1  

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP2VP2

Copper-core PE insulated, PVC sheathed, copper tape separate shield and general shield, intrinsically safe DCS cable

IAJYP3VRP3

Copper-core PE insulated, PVC sheathed, aluminum/plastic compound tape separate shield and general shield, intrinsically safe DCS flexible cable

IAJYP1VRP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, intrinsically safe DCS flexible cable

IAJYP1V22RP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, steel tape armored intrinsically safe DCS flexible cable

IAJYP1V32PR

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and woven copper wire general shield, small-gauge steel wire armored intrinsically safe DCS flexible cable    

ZR-IAJYPVP

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYPVRP

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP1VP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYP1VRP1

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP2VRP2

Copper-core PE insulated, 105°Cflame-retardant sheathed,copper tape separate shield and general shield, intrinsically safe DCS flexible cable

ZR135- IAJYPVRP3

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield, aluminum/plastic compound general shield, intrinsically safe DCS flexible cable

ZR-IAJYPV22RP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield, tinning copper wire general shield, steel tape armored intrinsically safe DCS flexible cable  

ZR135- IAJYP1V32RP

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning copper wire separate shield, woven copper wire general shield, small-gauge steel tape annoyed intrinsically safe DCS flexible cable

      1.Code and definition  

Item

Code

Definition

 

Flame-retardant

character

/

ZR

ZR-135

Non flame-retardant that can be omitted

General flame-retardant

135°C flame-retardant

Series code

IAJ

Intrinsically safe explosion-proof DCS cable

Insulation material

Y

V

VD

E      

PE

PVC

Low smoke and low halogen PVC  

Low smoke and halogen-free polyolefin

Shield material

P

P1

P2

P3

Woven copper wire shield

Tinning copper wire

Copper tape

Aluminum/plastic compound tape

Armor material

22

32

Steel tape armor

Small-gauge steel wire armor

Heat-resistant grade

70

105

135

Max.working temperature is 70°C,can be omitted

Max.working temperature is 105°C

Max.working temperature is 135°C

Conductor type

A

B

R

Single-strand conductor

7-strand twisted conductor (type A&B are marked after specification)

Multiple-strand flexible conductor

Specification

 

Pairs (or groups) x cores of each pair(or group) x conductor core section mm2

Pairs (or groups): 1,2,3. .. .24

Core of each pair (or group): 2, 3

Conductor core section s: 0.5, 0.75, 1.0, 1.25, 1.5, 2.5 (mm2)

  Note: Intrinsically safe cable required to be high-temperature-resistant, oil-resistant and acid/alkali corrosion-resistant, its types and materials can be referred to relevant items of computer cable. Based on the above-described type description for intrinsically safe explosion-proof DCS cable, different combinations can be selected to meet requirements.   SpecificationSize   1.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3, ZR-IAJYP2VP2(Twin type)   Cont table Note: The outer diameter of armored cable could add 4.0mm   2.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3,ZR-IAJYP2VP2(Triplet) Cont table   Note: The outer diameter of armored cable could add 4.0mm   FAQ   Marking Examples:   Example 1: Intrinsically safe DCS flexible cable selectingcopper-core PE insulation, PVC sheath, woven copper wirepair shield and general shield, nominal section of conductorcore is 1.0mm2, 19-strand twisted conductor with three 3-wire groups, can be expressed by:IAJYPVRP 3 x 3 x 1.0   Example 2: Intrinsically safe DCS cable selecting copper-core PE insulation. 105°Cflame-retardant PVC sheath.aluminum/plastic compound pair shield, woven copper wire general shield, nominal section of conductor core is 1.5mm2, 2pairs: Conductor-core applies single-strand copper wire: ZR-IAJYP3VP-105 2 x 2 x 1.5(A)   Conductor-core applies 7-strand twisted wire:   ZR-IAJYP3VP-105 2 x 2 x 1.5(B)   Packaging & Shipping   

Packaging Detail:

international wooden drums or according to your   requirement.

Delivery Detail:

In 15days or as the quantity   you required

      Our Services 1.Free samples can be afford if needed. 2.2 years warranty after selling     Company Information    
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628