Product description

Specifications 1.Micro-electrolysis+brine electrolysis both functions

2.Patented electrode

3.Transparent electrolyzing tube

4.5 years life

SCITEC sterilization and algae removal of cooling circulating water with sodium hypochlorite generator   Product Description  1. The NT-SSA series products, can both realize the both  functions   of  Micro-electrolysis & Brine electrolysis in one unit; this system can not only used for the swimming pool water disinfection, but also appliable for the circulating cooling water sterilization. It is perfect system.   2, On-site NAClO Generator Advantages:    In comparison of electrolysis sterilization coagulated water treatment technology and Ozone disinfection technology:

 

electrolysis sterilization coagulated water treatment technology

Ozone disinfection technology

Principle

  1. Microorganisms are killed by the produced active oxygen (such as O2-,1O2,OH,H2O2);
  2. Under the process of low-voltage electric field, there exists strong PH gradient, change he living environment of microorganisms and death rapidly. It will have sustainable bacteriostatic effect and be clearer due to electric coagulation.

Ozone disinfection, easy to be decomposed

Process features

Effect of the mixture sterilizing materials is better than Ozone and disinfectants with chlorine

Sterilization effect of Ozone is better than disinfectants with chlorine, but worse than activated oxygen

No need to add disinfectants with chlorine, cause H2O2 and activated oxygen in the treated water have sustainable bacteriostatic effect

Must add the disinfectants with chlorine to maintain sustainable bacteriostatic effect, and it is harmful for human health

Simple structure, little footprint

Complex preparation, huge equipment

Have function of electric coagulation, can reduce or not change amount of coagulant

Without function of electric coagulation

Safety

Problems about the tail gas and excessive dosing, have potential safety hazard

Full automatic, low technical requirements of operator

High technical requirements of operator

Activate water quality, lower hardness, soften water quality

Without this function

Low cost for devices

High cost for relying on import

Low running cost for 500m3 with 1.5KW

High running cost for 500m3 with more than 6KW

    System Flowchat:     Sterilization principles for  Micro-electrolysis & Brine electrolysis technology : 1)  Electric field treatment of water in the process of dissolved oxygen to be activated, creates O2-, OH, 1O2, H2O2, and other reactive oxygen species (superoxide anion free radical O2-is, OH is the hydroxyl radical, 1O2 Singlet oxygen, H2O2 is hydrogen peroxide). Sterilization of active oxygen free radicals is the strongest material, see figure to the right, on microbial organisms can produce a range of effects, main cause of death is caused by micro-organisms. A. O2- can damage important biological macromolecules causing microbial body injury; B. O2-increases microbial organism lipid peroxidation,, accelerate death.  For the water molecules occur some physical changes under the low electric pressure, and processor contains small oxidizing substances for their antimicrobial effect lasts 48 hours it.  Micro-electrolysis can be used to Cl-the amount of free chlorine in water, antibacterial efficacy of enhanced water quality of swimming pools to meet code for design of swimming pool.   The principle of clarification and turbidity reducing :        By treated under the low-voltage electric field, the Zeta potential of small colloid in water is reduced. The colloids are easy to polymerize then removed through sediment or filtration.  

Technical Parameters:

Applicable Water Temperature:0°C~50°C 
Working Pressure:≤0.6Mpa 
Sterilizing Rate:>99.9% 
Algae Removal Rate:>99.5%
Conductivity:1.0~1.5ms/cm
Legionella: Achieve international standards
Total bacterial count,coliforms,free residual chlorine meet the standard of National Swimming Pool (GB9667-1996)

National Hygienic standard for swimming place(GB9667-1996)

Project

Standard value

Project

Standard value

pH

6.8~8.5

Avaliable chlorine,mg/L

0.3~0.5

Turbidity

≤5

Total bacterial count,Pieces/ml

≤1000

Urea ,mg/L

≤3.5

Coliforms,Pieces/L

≤18

  2)  (Instead of the dangerous liquid chlorite and chlorine dioxide generator) Shanghai Sciyee Water Sci.&Tech. Co.,Ltd. (hereinafter refered to as "SCITEC") Generators use the advanced electrolyzing technology andDSA eletrode under the cooperative R&D by China and Germany for superior electrolyzing efficiency and energy-saving. The generators have demonstrated reliability, safety, economy operation in numberous large-scale water plants at home and abroad     Packaging & Shipping       FAQ  1. The after-sale service:  