SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization
SCITEC Electro-chlorination Generator for Swimming Pools Sterilization

1 / 6

SCITEC Electro-chlorination Generator for Swimming Pools Sterilization

Get Latest Price
Send Inquiry
Model No. : NT-SSA Series
Brand Name : SCITEC

Product description

Specifications 1.SCITEC Circulating Water Electro-chemical Sterilizer

2.Patented electrode

3.Transparent electrolyzing tube

4.5 years life

SCITEC Circulating Water Electro-chemical Sterilizer   Product Description   1. The purpose and significance of circulating water sterilization         In the circulating cooling water system, cooling water is recycled. Due to the change of water temperature, velocity, water evaporation, all kinds of inorganic ions and organic material concentrated; cooling tower and cooling water pool are affected by the outdoor sunlight, wind & raining, dust, equipment structure & material and a variety of factors. If effective measures aren’t taken, the equipment can be serious scaled, corrosion and many bacterium or algae microorganisms will be infested. The microbial corrosion and algae growth if cannot be handled in a timely manner, the heat exchanger would damaged, equipment would be forced to shut down.       2. SCITEC Sterilizer Introduction   SCITEC sterilizer way of Electrochemical is different from the traditional Electro Chlorination; it is the new technology called electro-catalysis. This technology is R&D upon the traditional circulating cooling water sterilization system. Since the 19 centuries, people dose the produced sodium hypochlorite solution to circulating cooling water system. The Electrochemical technology which developed by SCITEC, make the cooling water disinfected & be sustainable bacteriostatic effect while passing through the electrolysis modules.       The system adopts the part or whole over-current electro-catalysis continuously, at the same time make the equipment units simplify. All these steps promise the economical running costs & equipment invest costs. And link with the circulating water system, ensure its normal working.  
3. SCITEC Sterilizer Working Principles   1)  Direct effect of sterilizing alga: The ORP between electrodes produced while electrolysis & the strong oxidizing property OH-Radical produced on DAS titanium electrodes will attack the cell membrane of microorganisms together, for killing the alga.     At the same time, electrolytic produce hydroxyl radicals, ozone, hydrogen peroxide and sodium hypochlorite, they can destroy the cell nucleus, algae fungicidal effect completely. Because of hypochlorous acid is the strong oxidant, it is easy to protoplasm compounded through the microbial cell walls. When the concentration reaches a certain degree, it can damage the whole cells, so as to kill microorganisms. The residual hypochlorous acid in cooling water can completely prevent regeneration and propagation of microbes and algae.   Water in the circulating water system must be treated with SCITEC circulating water sterilization device once a day, to ensure the sterilization effect of alga.   2) Indirect effect of sterilizing alga: The treated cooling water which flow into the heat exchanger, cooling tower and cooling water pools have residual chlorine (0.1~0.2PPM), the residual chlorine can completely prevent regeneration and propagation of microbes and algae.   4. SCITEC Sterilizer Features   a.  No need to add the salt or other chemical disinfectants; environmental; the lowest corrosion. b. Only 1% capacity of the Bypass flow treatment. c. Cheaper, compared with dosing the sodium hypochlorite. d.  Transparent tube for checking work conditions of each piece electrodes. e.  Guarantee electrode life for three years(Circulating water conductivity is higher than 2000us/cm, water temperature>10℃),the electrodes can be coated again after losing efficacy. f.  SCITEC Circulating Water Electro-chemical Sterilizer, the system includes only the electrolysis generator part & rectifier; without the salt dissolving device, brine part, NaClO storage part, doing part, etc. g.  During the electrolysis process, the electro-coagulation functions can reduce or add no coagulant. The suspended substance can be cleared easily. h.  The treated circulating water has function of scale prevention. i.  The sterilizer has full automatically cleaning system, to prevent the generator scaling.    5. SCITEC Sterilizer Flow Chart     Packaging & Shipping       FAQ  1. The after-sale service:  
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628