rubber injection moulding machine relay temperature controller XMTF-6031
rubber injection moulding machine relay temperature controller XMTF-6031
rubber injection moulding machine relay temperature controller XMTF-6031

1 / 1

rubber injection moulding machine relay temperature controller XMTF-6031

Get Latest Price
Send Inquiry
Model No. : XMTF-6031-941
Brand Name : AOYI

Product description

                                              Temperature Controller     pt100 temperature controller XMTF-6031-941      Specification Introduction   XMT  Series  Intelligent  Temperature  Controller  adopts SCM for core which Micro anti-interference, large-capacity and advanced PID self-tuning method, and advance SMT technic, and the red/green double rows display measurement-value and setting-value at the same time.use advance components with software, multiple digital filter technology,stable performance, higher measurement accuracy and strong anti-interference. Various kinds of parameters can be set in the panel,  it can realize various classic or modern controlling technology like two digis, three digits, intelligent PID, and parameter auto-optimization& auto-adjusting according to different require, and is mainly uses in self-control system like  machines,chemical,ceramic,light industry,metallurgy petrifaction, petrochemical  and heat treatment.   Notice   --Thermal resistance or thermocouple input and measuring range both can be set freely. --Software adjust zero and full scale, temperature measuring of cold-end alone, amplifier constant-zero, display accuracy is better than 0.2%FS. --The method of fuzzy theory combine with the traditional PID makes the temperature be controlled quickly and smoothly. --The method of advanced PID parameter self-tuning saves a third time as compared with ordinary instrument. --The output signal is optional: relay output, DC12V driver solid state relay, 4-20mA current --Alarm output: two circuit user-defined alarm output.

Model

  XMTF-6031

Max Load Current

 

Input Specifications

K.(J).E.Pt100(set freely)

Output Signal

Relay contact ON/OFF     

Temp Control Range

(0-400 default) K(0-1350℃) ,J(0-1000℃) ,E(0-1000℃),Pt100(-200-650℃)

Precision

 0.5 class(±0.5%F+1)

Sampling Rate

Twice per second

Regulating Methods

Intelligent PID control, according to the value of P,I,D parameters, we can get P(P=0 is on-off control),PI,PD,PID regulating mode

Alarm function (optional)

/

Power supply

Transformer AC220V±10%

Power Consumption

≤3VA

Contact Capacity

 AC250V 2A (Resistive Load)

Contact Life

>10x104 times

Main Usage

  controlling temperature of AC contacter or ON/OFF in intermediate relay 

General Information

Ambient temperature

-10-50℃

Relative humidity:

≤85%RH (non-corrosive)

Storage temperature

-25~75℃

Dimension

96*48*82mm

Mounting size

45*92mm

Installation Mode

Panel Type

Waterproof level

IP67


    Dimension            Summary   Widely be used in industries relating with temperature, such as plastic, machinery, chemical industry, ceramic, light industry, metallurgy, heat treatment, etc. XMT series intelligent temperature controller is one kind of intelligent temperature adjustment device with digital temperature display, and it owns reliable power module, advanced PID self-setting methods, fuzzy PID control with advantages of good control effect, simple operation, high reliability and so on.   Temperature controller types when divided by main control output function: relay output, logic electric level output, phase-shift impulse output, zero-crossing impulse output, current output(0-20mA, 4-20mA_, controlled silicon output, etc.   Temperature controller types when divided by input signal: thermocouple input(K, J, E, S, N, T, B, R, WRe), thermal resistance input (Cu50, Pt100), linear voltage signal input(0-5V,1-5V), linear current signal input(0-10mA,0-20mA 4-20mA, outward shunt resistance is required).     Input Signal & Measuring Range   

 

 

Measuring Range

Input Signal

Measuring Range

Thermocouple

K

0°C~1350°C

Thermal Resistance

Pt100(1)

-200°C~650°C

J

0°C~1000°C

Pt100(0.1)

-199.9°C~199.9°C

E

0°C~1000°C

Cu50

-50°C~150°C

S

0°C~1750°C

Linear Signal (To be ordered)

0-5V

-1999~+9999 Can be defined by user

N

0°C~1300°C

1-5V

T

0°C~400°C

0-10mA

B

0°C~1800°C

0-20mA

R

0°C~1750°C

4-20mA

Rwe

0°C~2300°C

……

    Order Key         Alarm Output Explanation:    uUpper limit bias alarm: e.g, with setting value of 150°C, if the alarm value is 2°C, alarm return difference is 1°C, then the alarm starts output when the temperature rises to (150+2)°C, and it stops output when the temperature returns to(150+2-1)°C   uLower limit bias alarm: e.g, with setting value of 150°C, if the alarm value is 2°C, alarm return difference is 1°C, then the alarm starts output when the temperature returns to (150-2)°C, and it stops output when the temperature rises to (150-2+1)°C.   uUpper limit absolute value alarm: e.g, with setting value of 150°C, if the alarm value is 152°C, alarm return difference is 1°C, then the alarm starts output when the temperature rises to (150+2)°C, and it stops output when the temperature returns to (150+2-1)°C.   uLower limit absolute value alarm: e.g, with setting value of 150°C, if the alarm value is 100°C, alarm return difference is 1°C, then the alarm starts output when the temperature returns to 100°C, and it stops output when the temperature rises to (100+1)°C.     The user could select proper model according to applied place and requirement, such as temperature control range, input signal, drive required module, installing size and method, etc.   Company Information   Contact Us  
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.