rhodium platinum ceramic type s thermocouple Product Description High temperature type S B R thermocouple For the measurement of higher temperatures we offer thermocouples with ceramic tubes, upon request with additional ceramic inner tubes. The thermocouples (e.g. type S or type B) are insulated by a 2-hole or 4-hole insulating ceramic rod. The measuring point is laser-welded. The thermocouple is protected against environmental influences. We furnish all kinds of thermocouples with ceramic protective tubes at all lengths and designs. 1, Type and graduation
Comment: 1, Produce based on client's requirments 2, Methods of fixing: normally without fixing device, but flange or threaded is available B type WRR thermocouple specification: B type thermocouple’s standard wire diameter is 0.5mm. Positive pole material is Platinum - 70%, Rhodium - 30%; Negative pole is Platinum – 94%, Rhodium – 6%. Temperature can reach 1600 degree. It is suitable for oxidized condition and inert atmosphere Specifications and Advantages 1, High accuracy 2, Good stability 3, Wide temperature range: 0-1800 4, Long serving time 1,Noble metal temperature sensor
2,Stable and reliable performance
3,High temperature B/R/S type thermocouples S type WRP thermocouple specification: S type thermocouple’s standard wire diameter is 0.5mm. Plus-minustolerance is 0.015mm. Positive pole material is Platinum - 90%, Rhodium - 10%; Negative pole is pure platinum. Temperature can reach 1300 degree. It is suitable for oxidized condition and inert atmosphere Specifications and Advantages 1, High accuracy 2, Good stability 3, Wide temperature range: 0-1800 degree 4, Long serving time Photos View