reactive compensation cabinet indoor
reactive compensation cabinet indoor
reactive compensation cabinet indoor
reactive compensation cabinet indoor
reactive compensation cabinet indoor
reactive compensation cabinet indoor
reactive compensation cabinet indoor

1 / 5

reactive compensation cabinet indoor

Get Latest Price
Send Inquiry
Model No. : GBD
Brand Name : CODO

Product description

  There are difficult and easy things in the world. With joint hands (co-do), everything will become easy.                      Product Description The details show     Operating environment uAmbient temperature: -25℃ ~+40℃ uMaximum daily temperature difference: 25℃ uAltitude: ≤2000m, special design available over 2,000m uEnvironment relative humidity: annual average value≤90% uSeismic intensity: 8 Richter scale uPollution level: III uInstallation method: indoor installation   Notes: The above using environment applies to the company’s standard product. We can conduct special design according to special environment.      Power Supply Condition uSystem Standard Voltage: 400V, 690 (660)V uMaximum working voltage: 440V, 759V uRated frequency: 50Hz, 60Hz uPhase number: 3 Technical indicators uRated capacity: It is possible to be configured in accordance with users' demands with the single cabinet rated compensation capacity ≤600kvar. In case of an exceeding of this compensation capacity, it shall be advised to adopt the configuration of combination of the main cabinet with auxiliary cabinet. uGrouping condition: grouping arbitrarily based on users’ actual requirements uDynamic overload capacity: Long-time operation under 1.30 In (rated current). Over-current is the interaction result of harmonics and 1.1 Un (rated voltage). Long-time operation under 1.10 Un. Longest operation of 30min under 1.15 Un every 24 hours. uPower factor: over 0.95 (set between 0.8 and 1) uControlled pathway: 24 pathways :p style="background: white;">uRespond time: ≤20ms   uReactance rate: 5%, 6%, 7%, 12%, 13% uSwitching delay: set according to users’ requirements uProtection grade: IP30 (can be designed according to users’ requirements) uAC sampling voltage: the voltage of System power supply; AC sampling current: 0~5A uCabinet Type: GCK, GGD, MNS, etc. (it is possible to be manufactured according to users' requirements)     The engineering case     Technology    
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628