Model No. : | DHBV |
---|---|
Brand Name : | SHUAIHE |
Type : | Insulated |
Product description
Cold-resistant cable wire DHBV parameter description
Whether spot:no Certify:CCC Brand:SHUAIHE
Customizedprocessed:yes Core material:blank copper line Core number:2---108
Sheath material:Special mixture Maximum OD:customizedpr Sheath thickness:customizedpr
Nominal section:customizedpr Certify:CE Type:DHBV
Spec.:customizedp Trademark:SHUAIHE
The cold-resistance performance of the cable made of sheathed rubber produced by Qisheng Cable (Yangzhou) Co., Ltd. passed the ultra-low temperature impact and extremely low temperature bending test specified in the UL44 standard, and the flame retardant performance passed the bundled combustion test. Compared with the prior art, the mechanical properties of the sheath rubber produced by the company are not only higher than ordinary rubber, but also have the characteristics of low temperature resistance and medium resistance, and extend the service life of the cable under low temperature and oil conditions. The cold-resistant cable is professionally developed, with high quality and safety. The wire is used in specific environments, such as ice storage, northern (-40°C~80°C) plastics are not prone to cracks and maintain soft performance. The wire is made of imported copper. The product`s plastic is safe. Usage characteristics 1. Long-term permissible operating temperature of the cable conductor: 1.1 Polyvinyl chloride- or polyethylene-insulated cold-resistant cable: The maximum permissible operating temperature of the cable conductor is 70 °C. The maximum temperature of the cable conductor does not exceed 160 °C in the event of a short circuit (maximum duration not exceeding 5 s). 1.2 Cross-linked polyethylene insulated cold-resistant cables: The long-term allowable operating temperature of the cable conductor is 90 °C. The maximum temperature of the cable conductor does not exceed 250°C during a short circuit (maximum duration of not more than 5 s). 2. The minimum cold temperature of the cable is -60 °C; the temperature of the cable can be used in the outdoor environment for long-term operation is -60 °C ~ +40 °C. Allow the cables to be connected to and disassembled from the electrical equipment unit under the appropriate cold temperature rating. When wiring and disconnecting, slowly bend the cable. The bend radius is 5 times the cable diameter. There should be no impact on the cable during operation.
Send your inquiry to this supplier