Optical Fiber Identifier/Live Fiber Identifier/Dark Fiber Identifier with VFL Product Description AFL-400 Optical Fiber Identifier Description Optical Fiber Identifier can quickly identify the direction of transmitted fiber and display the relative core power without interrupting the current service. The fiber identifier recognizes modulation like, 270Hz,1KHz and 2KHz with continuous audible tone. There are four adapter heads available: Ø0.25, Ø0.9, Ø2.0 and Ø3.0. This OFI is powered by 2 pcs very normal AA batteries.
Features Easy-to-use with “ONE KEY” operation; Efficiently identifies the fiber transmission direction and frequency tone (270Hz, 1KHz, 2KHz) with audible warning; Displays the relative core power; Easy-to-replace adaptors; Durable metal housing and quality construction; Lower power indication. It's easy to carry and loss adaptors can be avoided with new adaptors box.
Specifications
Identified Wavelength Range | 800-1700 nm |
Identified Signal Type | CW, 270Hz±5%,1kHz±5%,2kHz±5% |
Detector Type | Ø1mm InGaAs 2pcs |
Adapter Type | Ø0.25 , Ø0.9, Ø2.0, Ø3.0 |
Signal Direction | Left & Right LED |
Singe Direction Test Range (dBm, CW/0.9mm bare fiber) | -46~10(1310nm) |
-50~10(1550nm) |
Signal Power Test Range (dBm, CW/0.9mm bare fiber) | -50~+10 |
Signal Frequency Display (Hz) | 270, 1k, 2k |
Frequency Test Range (dBm, Average Value) | Ø0.9, Ø2.0, Ø3.0 | -30~0 (270Hz,1KHz) |
-25~0 (2KHz) |
Ø0.25 | -25~0 (1KHz,2KHz) |
-20~0 (2KHz) |
Insertion Loss(dB, Typical Value) | 0.8 (1310nm) |
2.5 (1550nm) |
Additional Visual Fault Locator Function | 650nm, Output: 10mW |
Alkaline Battery(V) | 2pcs AAA batteries |
Operating Temperature(℃) | -10-+60 |
Storage Temperature(℃) | -25-+70 |
Dimension (mm) | 196X30.5X27 |
Weight (g) | 195 |
Contact Us
Shine Zhang | | |
Beijing W&F Technology Co., Ltd. |
T: 0086 010 51212818 F: 0086 010 67693310-616 Phone : 86-18612175687 |
Skype : stevenanychat WhatsApp : 18612175687 |
Products Showroom on Alibaba.com |
Hot-Selling
Packaging & Shipping Orders would be shipped within 3 working days upon receiving cleard payments when stock lasts. Delievery time depends on the shipping method, the following is the typical time: Faster courier(Such as EMS, DHL, UPS...) would take 3-7 days;
Air mail(Hong Kong air mail, Singapore air mail) would take 10-20 days.
Package might be delayed occasionally by the Customs or the carrier, we sincerely hope each customer could give a few more days when this happens
After Sale Service After-sales Service(except consumables products): > We guarantee all our electrical and mechanical parts for one year from the delivery date the machine running smooth in customer's place.
> We guarantee that each product is tested carefully and works very well before shipment. We strive for 100% customer satisfaction on every sale we complete.
> We are responsible for the whole lifespan of our products, and whenever you have questions during use, just call us, we are glad to offer technical support timely.
Life-long Maintenance Service:
> During the warranty period, we can repair or replace the defective parts for free.
> After the warranty time, we also repair the defective parts, but only charge part cost Company Information Beijing W&F technology Co.,LTD is founded in 2006. It is a hi-tech company specialized in manufacturing and trading fiber splicing machine and testing equipments . Our company is one of the biggest communication test instrument suppliers which is located in Beijing - the capital of China.
Our main products as below:
FAQ 1..What’s the lead time for all the goods that I required?
---About the 3-4 working days after getting payment.
2.What’s the warranty for your products?
----Normally it is 2 years.
3.What’s your payment term?
---It is 100% T/T in advance
4.What’s the MOQ for your products?
---1pcs is okay. 5. How will you ship to us ? ---- Normally it will takes 3-5 days by DHL or FedEx 6. My fusion splicer machine always has a larger splice loss,what reasons caused it? How solve?
--- 1).the electrodes are aging,you need to change new ones
--- 2).the electrodes are not installed very well,you need to re-install and fix the electrodes well.
--- 3).discharging current is not good,you need to do discharging experiment to make the current get the right point
7.splicing machine shows loss is not large,but it's larger when testing use a OTDR,what causes?how solve?
--- 1).the electrodes are aging,you need to change new ones
--- 2).discharging current is not good,you need to do discharging experiment to make the current get the right point
--- 3).Optical fiber end face is bad,there is something wrong with the cutting blades.You need to adjust the fiber cleaver & cutting blades to make sure end face is better
--- 4).There has dust in V groove,you need to clean V groove,microscope,electrodes etc