Normal on off 24v dc plastic valve 10nm electric actuator
Product Description
Rated voltage:AC/DC95-265V(Only Casting alumimum Cover),DC24V Rated torque:10N.m Installbelow (rated torque*0.75) N.m valves: 2-way, 3-way valve Wiringand feedback model: KT32S High performance brushless motor,Overload protection of internalmotor Itcan be used 20,000 times.*1 Two and more actutorscan be used in parallel
Technical Data
Electrical data Rated voltage | AC110V/AC230V | DC24V |
| Rated voltage range | AC/DC95-265V | DC20-28V |
Power consumption | 40W@running 1.6W@holding | 36W@running 0.25W@holding |
Peak current | 90mA@5ms @AC230V | 1500mA@5ms @DC24V |
Fuse | 1A | 5A |
Functionaldata Rated torque Connectingcable Angle of rotation Maxangle of rotation Manual operation Running time Operating frequency Sound power level
10N.m 7*0.2mm2 cable, voltage withstand AC300V (Length 800mm) 90±2° 360° Matching hexagonwrench,using at no power 15s Not continuousoperation operating cycle ≥1min Max50dB(A)
Working conditions
Position indicator Mechanical
| Electricity safety level | I Type(ground protection) | III(safety low voltage) |
Inflaming retardinglevel Enclosure
1.6mmHB/ UL94 test method IP67 As Per En60529/GB4208-2008 (all directions) F type can add bracket or dehumidifying heater
Insulation resistance | 100MΩ/1500VDC | 100MΩ/500VDC |
Withstand voltage | 1500VAC 1Min | 500VAC 1Min |
Medium temperature
≤80°can install to actuator directly >80° need to install heat radiation stand
Working environment Indoor or outdoor; if exposed to the rain or sunshine, need to install protective device for the actuator
Explosion-proof level Not explosion proof products, do not use them in flammable and explosive environment
Ambient temp Non-operationtemp Ambient humidity Shock resistance Vibration Installation notes
-20℃— 60℃(ABS )/-20℃— 80℃(Casting alumimum) ≤-40℃ or ≥80℃ 5-95%RH non-condensing ≤300m/S2 10 to 55 Hz, 1.5 mm double amplitude 360°any angle,need manual operation or allow for wiring space
Dimensions / weight Maintenance Certification Free maintenance CE / MA / AL Dimensions (LXWXH) See “Dimensions” Connection standard ISO5211 F03,F04,F05 Output axis specification Female octagonal or male square Hole deepness ≤17mm(Female octagonal)/6.5mm(Male square) Weight ABS material 0.62kg,Casting alumimum 0.82kg
Packaging & Shipping
Our Services DC24V DC12V series electric actuator wiring:
Control instructions: * If SW is disconnected;the actuatorwill drive valve close clockwise. When the valve is closed completely, 5 is connected with 6 ,giving signal of closing * If SW is connected,the actuatorwill drive valve open anticlockwise. When the valve is open completely, 5 is connected with 4 ,giving ignal of opening. * Notice 1: 5 is not connected with 4 6 ,when the actuator is running. * Notice 2:The feedback signal is a little earlierthan the actual position,so pleasedo not cut power, when you get the feedback signal.
Company Information Pov valve industry (Shanghai) Co., Ltd. after many years of field experience, R & D and design of products to meet the stringent requirements of today's industrial processing fluid, by creating the most value of quality products, providing personalized service and on-time delivery principle, we gained good reputation. Our success is built on integrity, the full range of control valve. Main products: pneumatic control valve, electric control valve, a valve, pneumatic angle seat valve, pneumatic diaphragm valve, electromagnetic valve etc.
FAQ 10nm electric actuator mounting with plastic ball valve, 2 way ball valve, 3 way ball valve;
Diagram1 UPVC plastic ball valve+bracket assembly Diagram2 3piece stainless steel ball valve assembly Diagram3 3piece stainless steel 3way ball valve assembly
Installed valve technicalrequirements 1.When installing ball valve, the max torque ≤15N.m.If the ball valve is out of operationfor a long time, and the torque value of first on or off is the max torque. Or you can choose ball valve with elastic sealing. 2. When installing butterflyvalve, the max torque≤13N.m.Because the torque value will increased by 10-20% after installing. 3.When installingdirect mount model valve, the hole deep ≤17mm.It requires cutting if the output shaft is longer than 17mm. 4. Pls pay attention to the following items if you install the bracket and coupling by yourself: * The intensity of bracket shouldmeet the using requirements: the bracket twisting extent≤0.2mm in the process of on or off. * The parallelism of bracket ≤0.5mm. * When processing the shaft hole at both end of the coupling,it is necessary to ensure the accuracyand concentricity. The purposeis to make sure the mechanical hysteresis ≤10°,otherwise it will cause the actuator unable to work. 5. Screwshould be installedspring washer,flat washer, and we suggest you daub some glue cement around the screw in case of screw loosening. 6. After installation, user should switch the valve on and off one time with handle device first. Modifying the valve after make sure it works well.