Product description
Technical specifications:
- Resistive type of loading, PF = 1.0, metal sheathed elements manufactured from high-grade nickel resistance wire
- Rated voltage: 3P4W, 220 to 240V, 380 to 415V AC, 50Hz or 127 to 138/220 to 240V/60Hz
- Cooling mode: forced air-cooled, fans mounted on side of the load bank blow horizontally internal or external power supply for fans
- Working mode: load step control
- Total testing capacity ranges from 0 to 1,000kW consisting of different combinations of 10, 20, 50, 100kW load setting switches plus a 0 to 10kW fine-tuning knob
- From 0kW to the maximum, any load combination is achievable
- Loading step resolution is 10kW
- Load bank adopts World-famous components including Siemens switches, knobs and indicators, ABB-circuit breakers as well as Omron intermediate relays ensuring reliable performance and longer service lifespan
- Parameter measuring accuracy grade: 0.5
- Loading control accuracy: ±5%
- Load bank protections: over-heating protection, cooling fans failure protection and overload protection with alarm
Two control modes available:
- Local manual control
- Optional: manual control via a remote control panel (max control distance is 20m)
Parameters display and measurement:- Control panel contains a LED back lighted multi-functional meter displaying voltage, current, loading power, reactive power, apparent power, power factor, frequency and more (optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing)
Operating environment:
- Altitude: ≤1,000m above sea level
- Ambient temperature: -10 to 40°C
- Relative humidity: ≤80% RH ventilated environment without explosive or corrosive dust
- Not allowed to use in rainy outdoor environment
Resistive type of loading, PF = 1.0, metal sheathed elements manufactured from high-grade nickel resistance wire
Rated voltage: 3P4W, 220 to 240V, 380 to 415V AC, 50Hz or 127 to 138/220 to 240V/60Hz
Cooling mode: forced air-cooled, fans mounted on side of the load bank blow horizontally internal or external power supply for fans
Working mode: load step control
Total testing capacity ranges from 0 to 1,000kW consisting of different combinations of 10, 20, 50, 100kW load setting switches plus a 0 to 10kW fine-tuning knob
From 0kW to the maximum, any load combination is achievable
Loading step resolution is 10kW
Load bank adopts World-famous components including Siemens switches, knobs and indicators, ABB-circuit breakers as well as Omron intermediate relays ensuring reliable performance and longer service lifespan
Parameter measuring accuracy grade: 0.5
Loading control accuracy: ±5%
Load bank protections: over-heating protection, cooling fans failure protection and overload protection with alarm
Local manual control
Optional: manual control via a remote control panel (max control distance is 20m)
Control panel contains a LED back lighted multi-functional meter displaying voltage, current, loading power, reactive power, apparent power, power factor, frequency and more (optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing)
Altitude: ≤1,000m above sea level
Ambient temperature: -10 to 40°C
Relative humidity: ≤80% RH ventilated environment without explosive or corrosive dust
Not allowed to use in rainy outdoor environment