New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan
New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan
New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan
New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan
New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan
New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan

1 / 4

New 2013 300 to 2,000kW Load Bank for Generator Load Testing, Long Service Lifespan

Get Latest Price
Send Inquiry
Model No. : KPLB- 800kva
Brand Name :
10yrs

Fuzhou, Fujian, China

Visit The Store

Product description

  • Technical specifications:
    • Resistive type of loading, PF = 1.0, metal sheathed elements manufactured from high-grade nickel resistance wire
    • Rated voltage: 3P4W, 220 to 240V, 380 to 415V AC, 50Hz or 127 to 138/220 to 240V/60Hz
    • Cooling mode: forced air-cooled, fans mounted on side of the load bank blow horizontally internal or external power supply for fans
    • Working mode: load step control
    • Total testing capacity ranges from 0 to 1,000kW consisting of different combinations of 10, 20, 50, 100kW load setting switches plus a 0 to 10kW fine-tuning knob
    • From 0kW to the maximum, any load combination is achievable
    • Loading step resolution is 10kW
    • Load bank adopts World-famous components including Siemens switches, knobs and indicators, ABB-circuit breakers as well as Omron intermediate relays ensuring reliable performance and longer service lifespan
    • Parameter measuring accuracy grade: 0.5
    • Loading control accuracy: ±5%
    • Load bank protections: over-heating protection, cooling fans failure protection and overload protection with alarm
  • Two control modes available:
    • Local manual control
    • Optional: manual control via a remote control panel (max control distance is 20m)
  • Parameters display and measurement:
    • Control panel contains a LED back lighted multi-functional meter displaying voltage, current, loading power, reactive power, apparent power, power factor, frequency and more (optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing)
  • Operating environment:
    • Altitude: ≤1,000m above sea level
    • Ambient temperature: -10 to 40°C
    • Relative humidity: ≤80% RH ventilated environment without explosive or corrosive dust
    • Not allowed to use in rainy outdoor environment
  • Resistive type of loading, PF = 1.0, metal sheathed elements manufactured from high-grade nickel resistance wire
  • Rated voltage: 3P4W, 220 to 240V, 380 to 415V AC, 50Hz or 127 to 138/220 to 240V/60Hz
  • Cooling mode: forced air-cooled, fans mounted on side of the load bank blow horizontally internal or external power supply for fans
  • Working mode: load step control
  • Total testing capacity ranges from 0 to 1,000kW consisting of different combinations of 10, 20, 50, 100kW load setting switches plus a 0 to 10kW fine-tuning knob
  • From 0kW to the maximum, any load combination is achievable
  • Loading step resolution is 10kW
  • Load bank adopts World-famous components including Siemens switches, knobs and indicators, ABB-circuit breakers as well as Omron intermediate relays ensuring reliable performance and longer service lifespan
  • Parameter measuring accuracy grade: 0.5
  • Loading control accuracy: ±5%
  • Load bank protections: over-heating protection, cooling fans failure protection and overload protection with alarm
  • Local manual control
  • Optional: manual control via a remote control panel (max control distance is 20m)
  • Control panel contains a LED back lighted multi-functional meter displaying voltage, current, loading power, reactive power, apparent power, power factor, frequency and more (optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing)
  • Altitude: ≤1,000m above sea level
  • Ambient temperature: -10 to 40°C
  • Relative humidity: ≤80% RH ventilated environment without explosive or corrosive dust
  • Not allowed to use in rainy outdoor environment
  • Send Inquiry