1 / 1
Model No. : | NCS-PTII105 |
---|---|
Brand Name : | Microcyber |
Product description
Model | Pressure type |
NCS-PT105ⅡS SG | Gauge pressure transmitter |
NCS-PT105ⅡS SA | Absolute pressure transmitter |
Measure object | liquid,gas,stream |
Power | 9-32V dc(FF,PA) 9-17.5VDC(FF,PA; explosion-proof) 11.9-42VDC(HART) 11.9-30VDC(HART; explosion-proof) |
Output | Analog:2 wire 4~20mA Digital:HART,FF and PA signal |
Load resistant | 0~1500ohm(common) 250~550ohm(use HART) |
Insulation | Voltage between terminal and housing:500Vrms(707VDC) |
Display | Optional 6 bits digital number or 5 bits characters LCD display |
Temperature | Work temperature: -40 ~ 85°C(without display) -30 ~ 70°C(with display) -30 ~ 60°C (explosion-proof IC) Store temperature: -40 ~ 100°C(without display) -40 ~ 85°C(with display) |
Humidity scale | 5%~100%RH |
Start time | ≤ 5 seconds |
Refresh time | 0.2 seconds |
Dump adjusting | Constant of time 0~15 seconds |
Precision | ±0.075% of the select range. If the select range <1/10 maximum of the range, the precision is ±[0.025+0.005×(maximum range/select range)]% of select range |
Temperature effect | Effect of every change of 28°C(50°F) Select range ≥0.1 maximum range:±[0.019% of maximum range +0.125% of select range] ; Select range <0.1 maximum range:±[0.025% of maximum range+0.125% of select range]. |
Long time stability | In 12 months, ±0.1% of maximum range |
Static pressure effect | ±0.25%/13.8MPa of maximum range |
Location installed effect | The maximum of the zero point movement is 0.24kPa |
Power effect | < 0.005%/V of range calibrated |
Explosion-proof | intrinsically safety Ex ia II C T4 |
Proof level | IP65 |
Vibration effect | IEC 60068-2-6 Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal) |
Electromagnetic compatibility | IEC 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test IEC 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
Electrical connection | 1/2-14 NTP Female |
Weight | 1.6kg (with LCD) 1.0kg (without LCD) |