1 / 6
Model No. : | MDR-40-24 |
---|---|
Brand Name : | weho 24v 1.7a power supply |
Product description
Related Products | ||
Wattage | 15W~1500W | |
Features | High number of economic type safety with series 3.3V, 5V, 7.5V, 9V, 12V, 15V, 24V, 27V,36V, 48V | |
Model No. Date Link | MS Series MS-15W MS-25W MS-35W MS-50W MS-60W MS-100W | |
S Series S-250W S-300W S-350W S-400W S-500W S-600W | ||
SCN Series SCN-600W SCN-800W SCN-1000W SCN-1500W | ||
DR Series DR-30W DR-45W DR-60W DR-75W DR-120W DR-240W | ||
MDR Series MDR-20W MDR-40W MDR-60W | ||
LPV Series LPV-15W LPV-20W LPV-30W LPV-50W LPV-60W LPV-100W LPV-150W LPV-200W LPV-250W | ||
NES Series NES-15W NES-25W NES-35W NES-50W NES-75W NES-100W NES-350W |
Model | Output | Tolerance Voltage | Ripple and Noise | Efficiency |
MDR-40-5 | 5V, 0-6.0A | ± 2% | 80mvp-p | 78% |
NDR-40-12 | 12V, 0-3.3A | ± 1% | 120mvp-p | 86% |
MDR-40-15 | 15V, 0-2.66A | ± 1% | 120mvp-p | 88% |
MDR-40-24 | 24V, 0-1.7A | ± 1% | 200mvp-p | 88% |
1. Universal AC input/ Full range | ||||
2. Installed on DIN rail TS35/ 7.5 OR 15 | ||||
3. Protection: short circuit/ over-load/ over-voltage | ||||
4. No load power consumption <0.75W | ||||
5. LED indicator for power on | ||||
6. DC OK signal output (20W) | ||||
7. DC OK relay contact (40W&60W) | ||||
8. Cooling by free air condition | ||||
9. 100% full load burn-in | ||||
10. 2 years warranty | ||||
Specification: | ||||
1. AC input voltage range: 85-264VAC; 120-370VDC | ||||
2. AC input current: cold start, 30A at 115VAC, 60A at 230VAC | ||||
3. DC adjustment range: 0±20% rated output voltage | ||||
4. Over-load protection: 105-150% constant current limiting, auto-recovery | ||||
5. Over-voltage protection: 125%-150% rated output voltage | ||||
6. Setup, rise, hold up time: 500ms,30ms,50ms AT FULL LOAD AND 230VAC | ||||
7. Withstand voltage: I/P-O/P:3KVAC, I/P-FG: 1.5KVAC, 1minute | ||||
8. Working temperature: -20-60°C@100%, 70°C@50% load | ||||
9. DC OK signal: relay contact | ||||
10. EMC standards: EN55022 class B, EN61000-3-2,-3, EN50204, EN61000-4-2,3,4,5,6,8,11, EN61204-3, (EN61000-6-2 heavy industry level also for 40W&60W) | ||||
11. Connection: I/P: 3 poles, O/P: 3poles screw DIN terminal | ||||
12. Dimension (L*W*H): 40*90*100 mm | ||||
Please Note: | ||||
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%Rh, Humidity. | ||||
2. Error, include the setting error, line stability and load stability. | ||||
3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. | ||||
4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. | ||||
5. Load stability test: the load is from 0% to 100%, others 60%. | ||||
6. Total stability test: the load is from 0% to 100%, others 60%. | ||||
7. C2,3,6 must be knocked down. |