MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV
MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV
MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV
MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV
MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV
MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV

1 / 4

MINI Automatic plate heat exchanger and cooling system intelligent monitoring Alfa lava and APV

Get Latest Price
Send Inquiry
Model No. : OEM
Brand Name : Joylong

Product description

INTRODUCTION: Jinlong plate heat exchanger transfers heat between warm side and cold media. The media are separated by a metal plate wall with polymer gasket seals. The compressed plates form flow channels through which the medium passes. Heat transfer takes place through the plate wall. The counter current flow together with a plate design that induces evenly distributed turbulent flow in the liquid streams, thin plate material and plate-to-plate contact ensure highly efficient heat transfer and minimum pumping costs.   Production formation:   Make-up pump   l With functions of variable frequency constant pressure water inlet, a simple man-machine interface, simple operation analysis, artificial intelligence controls algorithm, requires the user to set less parameter to keep stable.   l Our machine can automatically switch the standby pump regularly to prevent the spare pump for a long time without rust.   l Our machine can set two filling water pressure and the system of dynamic and static pressure in the circulation pump can automatically switch start or stop.   l The function of automatic self-protection, our machine can stop automatically when water tanks Lack of water to prevent pump idling.   l  The function of automatic drainage, the system in the thermal expansion can automatically open pressure solenoid valve to pressure relief       Circulating pump   l Circulating pump controls pressure by the system of automatically frequent conversion. According to the second circuit supply, return water pressure or supply pressure our machine automatically adjust the rotated speed of circulating pump to ensure the second circuit outlet pressure ,temperature of the supply and return water pressure stable.   l Our machine can control three circulation pumps automatically. When a circulating pump cannot meet the second circuit supply pressure (or flow) requirements, the system will automatically change a circulating pump from the variable frequency to work frequency state, and then our machine will use the second circulating pump. If two pumps cannot satisfy the system requirements, our machine will start the third pump into work frequency conversion.     l  When outside thermal load are decreased, the system will stop the circulating pump in turn to keep pressure and temperature normal, which lead the Variable flow of second circuit to realize automatic adjustment and achieve automatic and energy saving effect. Because our machine adopts the technology of frequency conversion, the operate of high power cycle pump is controlled by frequency conversion, no surge, the power grid of heating pipe network pressure shock, also greatly reduces the damage rate of the pipes, valves, heat exchange station power transformer capacity requirements at the same time also greatly reduced, saving investment and maintenance costs.     A net flow regulating function of control system   l Because regulator valveopening of the primary circuit is automatically controlled by the temperature of the second circuit, the outlet temperature of second circuit is stable.   l Automatically compensatory system adjusts to outside temperature. According to the change of outside temperature, our machine automatically adjusts the outlet temperature of the second circuit. The outside temperature is higher, the outlet temperature of the second circuit less lower. The outside temperature is lower, the higher the outlet temperature of the second circuit.     l  The operator can adjust the flow regulating valve opening by computer controller.   l  The operator can set energy saving mode and set period of time by man-machine interface       SMS fault remote alarm functions   l  Unattended heat exchanger station needs to be equipped with automatic fault alarm. After equipped with SMS remote fault alarm system, the automatic system will send messages including equipment trouble to one or more phones so that maintenance personnel can deal with trouble in time. System can detect failures including the inverter failure; Pump failure; Fill the tank water shortage; Circulation pump failure, etc       Sensor fault protection and control function   l  With functions of temperature sensor short-circuit and single-line display Chinese characters.   l  With pressure sensor bolt system protection function, the system can automatically detect break state by pressure sensors in order to prevent filling water pressure is too high to break down pipes and heating equipments.     The automatic fault diagnosis function   l  Automatic fault diagnosis function. When make-up water pump overpressure, the protection system automatically stop the pump according to the set pressure.   l  When circulating pump or make-up water pump break down, the system automatically switch standby pump in order to keep system normal.     l  When make-up water tank water shortage, the system will stop the pump automatically.   l  The system will alarm when the system over temperature more than set temperature and the system will automatically close the valve in order to ensure normal temperature system.       Benefit analysis   l  The central heating energy consumption is influenced by many factors including equipment operation and equipment adjustment reaction. Joylong developed automatic unattended heat exchanger unit that fundamentally solved the two key issues. Our machine can control the way of operation,constantly monitor outdoor temperature and adjust the secondary outlet temperature and flow rate.   l The control system adopts the imported products, mature control technology and multiple working modes. After the test, the same central heating system using energy-saving control system can save energy about 15% more than without using the energy-saving control system.     Select mode    

Automatic heating unit model selection table(steam-water)

Unit model

QBJ/Q-

HTM steam at a time

95/70 water

Plate heat exchanger

Circulating pump

Make-up pump

Boundary dimension

Weight

Kg

Heating area

×10^4/m^2

Heating load

Kw

Model

Flux

10^3/h

Lift

m

Power

Kw

Flux

10^3/h

Lift

m

Power

Kw

Length*width*high

QBJ/Q-3

0.4

240

BR01-3

9-16.2

30-50

3-4

3

30-50

0.75-4

2.8*1.0*1.8

2500

QBJ/Q-5

0.6

400

BR01-5

9-16.2

30-50

3-4

3

30-50

0.75-4

2.8*1.0*1.8

2500

QBJ/Q-8

1.0

640

BR02-8

18-35

30-50

5.5-15

3

30-50

0.75-4

2.8*1.0*1.8

2500

QBJ/Q-10

1.3

800

BR02-10

18-35

30-50

5.5-15

3

30-50

0.75-4

2.8*1.0*1.8

2500

QBJ/Q-15

2.0

1200

BR02-15

32-65

30-50

7.5-15

6.5

30-50

2.2-4

3.0*1.0*2.0

3000

QBJ/Q-20

2.6

1600

BR03-20

72-126

30-50

7.5-30

6.5

30-50

2.2-4

3.0*1.0*2.0

3000

QBJ/Q-30

4.0

2400

BR03-30

72-126

30-50

7.5-30

6.5

30-50

2.2-4

3.0*1.0*2.0

3000

QBJ/Q-40

5.3

3200

BR06-40

120-200

30-50

18.5-37

6.5

30-50

2.2-4

3.0*1.0*2.0

3000

QBJ/Q-50

6.6

4000

BR06-50

120-200

30-50

18.5-37

9

30-50

3-5.5

3.2*.1.2*2.0

4000

QBJ/Q-60

8.0

4800

BR06-60

120-200

30-50

18.5-37

9

30-50

3-5.5

3.2*.1.2*2.0

4000

           
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628