Low Smoke Armoured Electrical Xlpe Power Cable For Underground ( 10 - 2500mm2 )
Low Smoke Armoured Electrical Xlpe Power Cable For Underground ( 10 - 2500mm2 )
Low Smoke Armoured Electrical Xlpe Power Cable For Underground ( 10 - 2500mm2 )

1 / 1

Low Smoke Armoured Electrical Xlpe Power Cable For Underground ( 10 - 2500mm2 )

Get Latest Price
Send Inquiry
Model No. :
Brand Name :

Product description

Detailed Product Description

 

Low Smoke Armoured Electrical XLPE Power Cable For Underground ( 10 - 2500mm2 ) 

 

 

Quick Detail

 

Insulation Material

XLPE

Type

High Voltage

Application

Underground

Conductor Material

Copper

Jacket

PVC

Character

waterblock

 

 

Description

 

XLPE-insulated power cables for rated voltage 110kV should perform the rules of XLPE-insulated Power 

Cable for Cable for Rated Voltage 110kV and its attachments in GB/T 11017-2002, which is equal to The 

Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.

XLPE-insulated power cables for rated voltage 220kV should perform the rules of XLPE-insulated Power 

Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 18890-2002, which is equal to The 

Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV in 

IEC 62067:2001.

XLPE-insulated power cables for rated voltage 500kV should perform the rules of XLPE-insulated Power 

Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 22078-2008, which is equal to The 

Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV in IEC62067:2006.

XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements 

of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.

 

 

Main Performance

 

1. The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;

                                 64/110kV, max. voltage Um=126kV;

                                127/220kV, max voltage Um=252kV;

                                 290/500kV, max voltage Um=550kV;

2. permissible long-term working temperature of cable conductor:90℃;

3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor should 

not exceed 250℃. When there exits line joints, the temperature of tin soldering ones should not exceed 

120℃, the temperature of crimping ones should not exceed 150℃, and the temperature of electric or gas

 welding should not exceed 250℃;

4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables.

   After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables.

1. When laying, ambient temperature≥0℃(when the cable has to be laid under the ambient temperature 

below 0℃,it is necessary to preheat the cable above 0℃)

2. When laying, the cable is not limited by disparity with the satisfaction of mechanical pressure, but it is not 

permissible to lay the cable in the iron pipe, nor the circular iron materials around fixed cables.

 

 

Applications

 

the type, name, and suitable areas

 

type

 

Description

 

Suitable for

Copper-conductor

AL-conductor

YJV,YJY

YJLV, YJLY

XLPE insulated 

PVC/PE sheathed 

power cable

Installation in the tube, 

channel or in air, resistant certain

 tension

YJSAV-Z

YJLSAV-Z

Vertical water power cables with

 XLPE-insulated, copper wire shielded, 

Al-plastic composite tape and PVC jacked

Installation in the tube, 

or channel resistant the damp

 environment and certain tension 

YJSAY-Z

YJLSAY-Z

Vertical water power cables with 

XLPE-insulated copper wire shielded, 

Al-plastic composite tape and PE jacked

YJLW02-Z

YJLLW02-Z

Vertical water power cables with

 XLPE-insulated,corrugated

 aluminum and PVC jacked

Tunnel or pipeline, 

moist places like higher water

 level underground, good capacity

 of anti-moisture and certain 

pressure available; specially used

 in the places with low corrosion 

and bearing certain mechanical 

force(such as bridge, vertical well 

and so on with the direct connection

 to transform); PE jacked with good

 capacity of anti-moisture. 

YJLW03

YJLLW03

Vertical water power cables with 

XLPE-insulated, corrugated 

aluminum and PE jacked

YJQ02-Z

YJLQ02-Z

Vertical water power cables with 

XLPE-insulated,

 lead set and PVC jacked

Tunnel or pipeline, 

moist places like higher water

 level underground, certain 

tension and shock resistant;

 specially used in the places with 

heavy corrosion but without nitric

 acid, acetic acid, organic matter

(e.g. peat), and strong alkali 

corrosion quality; certain 

mechanical force(tension, 

pressure, shock) available; 

PE jacked with good capacity 

of anti-moisture.

YJQ03-Z

YJLQ03-Z

Vertical water power cables

 with XLPE-insulated, 

lead set and PE jacked 

 

 

Note: 1.The table only lists the main types. According to the requirements if clients, the types of flame-resistant, rat proof, termite proof and so on , can also be produced, then the prefix of “ZC, FS, FY”

 should be added.

 

Specifications

 

Type

UO/U 

Rated voltage

Number 

of cores

Nominal cross-section mm2

YJV,YJLV,YJY,YJLY

YJSAV-Z,YJSAV-Z

YJSAY-Z,YJLSAY-Z

YJLW02-Z,YJLLWO2-Z

YJLW03-Z,YJLLW03-Z

YJQ02-Z,YJLQ02-Z

YJQ03-Z,YJLQ03-Z

38/66 48/66

 

240,300,400,630,800,1000,1200,

1400,1600,1800,2000,2500

64/110

1

240,300,400,500,630,800,1000,1200,

1400,1600,1800,2000,2500

127/220

1

300,400,500,630,800,1000,1200,1400,

1600,1800,2000,2500,3000

290/500

1

630,800,1000,1200,1400,1600,1800,

2000,2500,3000,3500

 

 

Note: The aluminum conductor is not recommended concerning to cables for voltage exceeding 220kV.

 

Competitive Advantage

 

1.Vertical water power cables with XLPE-insulated, corrugated aluminum and PVC jacked.

2.Tunnel or pipeline, moist places like higher water level underground, good capacity of anti-moisture

 and certain pressure available;

3. specially used in the places with low corrosion and bearing certain mechanical force(such as bridge, 

vertical well and so on with the direct connection to transform); 

 

The Framework of our Management:

 

Low Smoke Armoured Electrical XLPE Power Cable For Underground ( 10 - 2500mm2 )

 

The Main Process of Production :

Low Smoke Armoured Electrical XLPE Power Cable For Underground ( 10 - 2500mm2 )

 

 

The finished goods with packaged :

Low Smoke Armoured Electrical XLPE Power Cable For Underground ( 10 - 2500mm2 )

 

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628