Handheld Capnograph Vital Signs Monitor MODEL KGW100C
Handheld Capnograph Vital Signs Monitor MODEL KGW100C
Handheld Capnograph Vital Signs Monitor MODEL KGW100C

1 / 1

Handheld Capnograph Vital Signs Monitor MODEL KGW100C

Get Latest Price
Send Inquiry
Model No. : KGW100C
Brand Name : KAGUWI

Product description

Specifications Capnograph Vital Signs Monitor Parameters: SpO2, pulse rate, ETCO2, and RRWith the Mainstream CO2 probe, this device can measure

Capnograph Vital Signs Monitor Parameters: SpO2, pulse rate, ETCO2, and RRWith the Mainstream CO2 probe, this device can measure Scope of application:  The Vital Signs Monitor is a low cost monitor for spot checking, continuous, noninvasive monitoring or recording of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate and pulse strength. The monitor is a battery or AC adapter powered pulse oximeter. It may be used in the hospital, clinical environment, homecare, and during emergency land transportation. The oximeter works with given sensors providing SpO2 and pulse rate on all patients from neonatal to adult. 

With the Mainstream CO2 probe, this device can measure end-tidal CO2, FICO2, and Respiration Rate.

This device is intended for continuous patient monitoring with adjustable alarm limits as well as visible and audible alarm signals.   Technical Specifications    1. Parameters: SpO2, pulse rate, ETCO2, and RR
   2. Six display modes:   3. Power supply       • AC power: 100-240VAC,47-63Hz       • Four AA 1.5V alkaline or Ni-MH cells       4. SpO2       • Range:0-100%       • Accuracy:±2 at 70-100%       • Resolution: 1%       • Display Response: The display is for functional saturation. The pulse strength bar graph is not proportional to pulse volume. 
      5. Pulse rate       • Range: 30-250bpm       • Accuracy: ±2 at 30-250bpm       • Resolution: 1bpm
      6. ETCO2     • Range: 0% ~ 20% (0 ~ 150mmHg)
    • Accuracy: ±2 mmHg @ 5.0% CO2 (at BTPS), < 10% of reading @ > 5.0% CO2 (at BTPS)
    • Resolution: 0.1 mmHg
    • Display Response: The display is for functional saturation. The pulse strength bar graph is not proportional to pulse volume. 
  5. RR     • Range: 0~150 (BPM)
    • Accuracy: ±1bpm     • Resolution: 1bpm       Environment Specification       • Operating temp:0 to 45°       • Storage temp:-20 to +55°       • Relative humidity: 30 to 95%(operating),10 to 95%(storage), 0-95% (shipping)  