1 / 4
Model No. : | HDS |
---|---|
Brand Name : | MaiJieKe |
Changzhou, Jiangsu, China
Product description
Grain Dryer/Paddy Drier for Grain
Through airflow control and movement, products processed can achieve uniformity and thorough drying.
The tower dryer is ideal for slow and uniform drying.
Project | Basic equipment and technical parameters | ||||
Type | HDS- L20000D-Y | HDS- L25000D-Y | HDS- L30000D-Y | ||
Max. batch processing capacity(kg) | 20000 | 25000 | 30000 | ||
Overall dimension | L(mm) | 4702(Base dimension 3212) | |||
W(mm) | 3680(Base dimension 2494) | ||||
H(mm) | 10690 | 11690 | 13190 | ||
Weight(kg) | 5600 | 6000 | 6400 | ||
Air feeder | Type | baroclinic current | |||
Quantity | 2 | ||||
Diameter(mm) | Φ750 | ||||
Revolutions(rpm) | 1850 | ||||
Combustor | Model | GPM-30 | |||
Type | Double nozzle of gun shape | ||||
Ignition method | automatic ignition | ||||
Heating method | Direct heating | ||||
Fuel | diesel/ kerosene | ||||
Max. fuel consumption(l/h) | 33 | ||||
Hot wind temperature(℃) | 40-70 | ||||
Power(kw/h) | 0.37 | ||||
Heating efficiency | Above 85% | ||||
Hot wind stove | Model | HDS-WFL-30 | |||
Type | Hot wind | ||||
Ignition method | Manual ignition | ||||
Ignition method | Indirect heating | ||||
Fuel | Coal | ||||
Max. fuel consumption(kg/h) | 90 | ||||
Hot wind temperature(℃) | 40-70 | ||||
Power(kw/h) | 3.3 | ||||
Heating efficiency | Above 60% | ||||
Rated voltage(V) | Single phase 220/ Three-phase 380 | ||||
Max. power(kW) | Fuel type 15.3kw/hot wind type 18.2kw | ||||
Characteristics | Loading time(min) | 40 | 50 | 55 | |
Unloading time(min) | 45 | 55 | 60 | ||
moisture removal rate(%/h) | 0.6-1.0 | ||||
Single cycle time(min) | 58 | 58 | 64 | ||
Max oil consumption(l/h) | 33 | ||||
Drying capacityt%/h | 17.8 | ||||
Drying unevenness | ≤1% | ||||
Treatment capacity | moisture removal 5%(t/h) | ≥3.57 | |||
moisture removal 10%(t/h) | ≥1.78 | ||||
moisture removal 20%(t/h) | ≥0.89 |
Project | Technical parameter and specifications | ||||
Model | HDS-RFL-15 | HDS-RFL-30 | HDS-RFL-45 | HDS-RFL-60 | HDS-RFL-90 |
Dimension (L×W×H) mm |
2480×1280×1950 | 2780×1680×2300 | 2780×1680×2300 | 3950×2050×2400 | 4680×2250×2700 |
Overall machine weight (kg) | 1500 | 3000 | 3000 | 4500 | 6000 |
Equipment heating capacity kj/h | Above 150,000kcal | Above 300,000kcal | Above 450,000kcal | Above 600,000kcal | Above 900,000kcal |
Valid loading capacity (set) | 1 set plus 1 | 1 set plus 2 | 1 set plus 3 | 1 set plus 4 | 1 set plus 6 |
Coal consumption kg/h |
35-45 | 80-90 | 110-130 | 170-180 | 240-270 |
Applicable coal types | heat> 5000 kcal | heat> 5000 kcal | heat> 5000 kcal | heat> 5000 kcal | heat> 5000 kcal |
Secondary air fan power and voltage kw/v |
0.75/220 | 1.1/220 | 1.1/220 | 2.2/220 | 2.2/220 |
Power and voltage of fume exhaust fan kw/v |
1.5/380 | 2.2/380 | 3.0/380 | 5.5/380 | 5.5/380 |
Power consumption kw/h |
≤2.25 | ≤3.3 | ≤4.1 | ≤7.7 | ≤7.7 |
Machine voltage V |
220/380 | 220/380 | 220/380 | 220/380 | 220/380 |
Machine control type | Manual / Auto | Manual / Auto | Manual / Auto | Manual / Auto | Manual / Auto |
Machine control accuracy ℃ | ±1 | ±1 | ±1 | ±1 | ±1 |
Changzhou, Jiangsu, China
Send your inquiry to this supplier