GaiaField ground target large range scanning hyperspectral imaging system
GaiaField ground target large range scanning hyperspectral imaging system
GaiaField ground target large range scanning hyperspectral imaging system

1 / 1

GaiaField ground target large range scanning hyperspectral imaging system

Get Latest Price
Send Inquiry
Model No. : GaiaField
Brand Name : zolix

Product description

GaiaField ground target large range scanning hyperspectral imaging system, that is the ground remote sensor which uses the advanced hyperspectral imaging technology. The core of the system is one imaging spectrograph, which could make the hyperspectral scanning for long distance, large range target object, and get the object imaging and spectrum information. Widely used in target recognition, camouflage and counter camouflage research application field and ground objects telemetry, ocean water remote measurement environment research field, such as crop growth condition monitoring, insect pest monitoring and a wide range of fruit and vegetable maturity monitoring, etc.
   

 
Model(Gaia-)
V10
V10E
N17E
N25E
Spectral Range (nm)
VNIR
VNIR
NIR
SWIR
Standard lens focal length (mm)
25
25
25
25
Vertical direction visual angle (FOVac,°)
20
20
20
20
Vertical direction visual angle resolution
(IFOVac,°)
0.05
0.01-0.05
0.05
0.05
Horizontal scanning angle range(FOVal,°)
45
45
45
45
Horizontal direction instantaneous perspective(IFOVal,°)
0.1
0.05
0.05
0.05
Scanning speed(line images/s)
25-120
25-120
100
100
Scanning format(m,vertical orizontal, from10m)
3.5×8
3.5×8
3.5×8
3.5×8
Rechargeable battery full charged standby time (hours)
8
8
8
8
          There are three spectral ranges for GaiaField imaging spectrograph, VNIR (400-1000nm), NIR (900-1700nm) and SWIR (1000-2500nm).
 
GaiaField Specifications *

Portable design, equipped with long life battery, long time outdoor measurement
GaiaField ground targets large range scanning hyperspectral imager using portable design, easy to carry,also equipped with long life rechargeable lithium ion battery, up to 12 hours.

Reflectivity measurement model  
        GaiaField ground target large range scanning hyperspectral imaging system is based on the natural light
environment, for the reflectivity measurement of vegetation, lakes, oceans, forest and so on, through the
absorption spectrum analysis. The picture on the right is a typical vegetation full-wave band reflection
spectrum. With vegetation for example, research shows
that, the main influencing factors for vegetation reflectivity
are vegetation color characteristics, cell tissue structure
and moisture content.
 

For the actual application of crops growth monitoring, usually can use visible - near infrared band (400-1000 nm or 400-1700 nm) for the measurement, chlorophyll monitoring and nitrogen nutrition monitoring. From the spectrum, it is blue shift and red edge phenomenon, which reflect the strength of the plant photosynthesis (i.e. plant vigor). Blue shift said weakened vitality. According to the research and application of some water, usually adopts full band (400-2500 nm) reflectivity spectrum measurement that can reflect water soluble substances, chlorophyll and suspended matter situation.

Full-wave band, provide more than 700 spectrum channels
        GaiaField ground targets large range scanning hyperspectral imaging system used high resolution imaging spectrometer, in visible light band spectral resolution as high as 3 nm, in short wave infrared band can
achieve 10 nm spectral resolution, therefore full-wave band can get more than 700 spectrum channels, more spectral channel means more information, which can help the researchers to gain more research details information through the continuous spectrum analysis.
 
 
Standard three dimensional data cube data format, can be directly processed by the ENVI software.
 
 

         440nm 

             550nm

           670nm

            720nm

           750nm

GaiaField-V10-PS—Visible light-NIR ground target hyperspectral imaging system

System includes:
V10 hyperspectral imaging spectrograph, data Acquisition software,
tripod, rechargeable batteries.
System features:
Can be used for long distance, large range target object hyperspectral
imaging
Scanning format: 3.5m×8m (distance 10m)
Vertical direction visual angle (FOVac) 20°
Horizontal scanning angle range(FOVal) 45°
Horizontal direction instantaneous perspective(IFOVal) 0.1°
Wavelength range 400-1000 nm
The scanning head could be aligned manually (pitching ±90 °, rotating ±180 °)
Scanning head using tripod universal interface
Rechargeable battery full charged standby 8 hours

 

GaiaField-V10-PS Specifications

Hyperspectral imaging system
1. Imaging spectrograph
Wavelength range: 400nm-1000nm
Spectral resolution: 9nm
Spectrum sampling point: 0.63nm
Slit height: 9.8mm
Slit width: 50μm
Numerical Aperture: F/2.8
Total Efficiency >50%
Stray light: <0.5%
2. Lens
Wavelength range:400-1000nm
Focal length: 25mm
Aperture:F/1.4~F/17
C-Mount
Transmittance:≥85%
vision angle: 20°
3. CCD
Type: room temperature CCD
Pixels in Full Frame: 1392x1040
Pixel Size: 6.45*6.45μm
Interface: Ethernet
Frame Rate: 25 –120fps
Exposure time range:1μs-120s
A/D: 14bits
Lens mount: C-Mount
Dynamic range: 60dB
Spectral image acquisition software
1. Spectrum and image data acquisition in real-time.
2. Spectral data visualization and storable.
 
3. Selecting any position in the image by mouse, thesoftware can show the spectrum of that location.
4. Camera parameters settings, control of sample
stage speed.
5. Datacubes are saved in ENVI compatible format
that allows further processing by several software
packages for hyperspectral data processing.
Integrated automatic scanning
Horizontal scanning angle range: 45°
Scanning angle resolution 0.1°
USB2.0
Tripod maximum load >10kg
Tripod minimum height: 0.6m
Rechargeable battery full charged standby 8 hours
Image processor
CPU: 2.0GHz
Memory: greater than or equal to greater than or equal to 2GB
Hard disk capacity: 500GB
Discrete graphics: no less than 512M independent
video memory
Weight: 8Kg
Portable integration design

GaiaField-V10E-PS—Visible light-NIR enhanced ground target hyperspectral imaging system

System includes:
V10 hyperspectral imaging spectrograph, data Acquisition software, tripod, rechargeable batteries.
System features:
Can be used for long distance, large range target object hyperspectral Imaging
The scanning head could be aligned manually (pitching ±90 °, rotating ±180 °)
Scanning format: 3.5m×8m (distance 10m)
Vertical direction visual angle (FOVac) 20°
Horizontal scanning angle range(FOVal) 45°
Horizontal direction instantaneous perspective(IFOVal) 0.05°
Wavelength range 400-1000 nm
Scanning head using tripod universal interface
Rechargeable battery full charged standby 8 hours
 

GaiaField-V10E-PS—Specifications
Hyperspectral imaging system
1. Imaging spectrograph
Wavelength range: 400nm-1000nm
Spectral resolution: <3nm
Spectrum sampling point: 0.63nm
Slit height: 14.2mm
Slit width: 30μm
Numerical Aperture: F/2.4
Total Efficiency >50%
Stray light: <0.5%
2. Lens
Wavelength range:400-1000nm
Focal length: 25mm
Aperture:F/1.4~F/17
C-Mount
Transmittance:≥85%
vision angle: 20°
3. CCD
Type: room temperature CCD
Pixels in Full Frame: 1392x1040
Pixel Size: 6.45*6.45μm
Interface: Ethernet
Frame Rate: 25 –120fps
Exposure time range:1μs-120s
A/D: 14bits
Lens mount: C-Mount
Dynamic range: 60dB
Spectral image acquisition software
1. Spectrum and image data acquisition in real-time.
2. Spectral data visualization and storable.
 
3. Selecting any position in the image by mouse, the
software can show the spectrum of that location.
4. Camera parameters settings, control of sample
stage speed.
5. Datacubes are saved in ENVI compatible format
that allows further processing by several software
packages for hyperspectral data processing.
Integrated automatic scanning
Horizontal scanning angle range: 45°
Scanning angle resolution 0.05°
USB2.0
Tripod maximum load >10kg
Tripod minimum height: 0.6m
Rechargeable battery full charged standby 8 hours
Image processor
CPU: 2.0GHz
Memory: greater than or equal to 2GB
Hard disk capacity: 500GB
Discrete graphics: no less than 512M independent
video memory
Weight: 8Kg
Portable integration design 
 
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628