Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant
Flow Lab Use Compact Nitrogen Generation Plant

1 / 5

Flow Lab Use Compact Nitrogen Generation Plant

Get Latest Price
Send Inquiry
Model No. :
Brand Name : Gamma Gas
Usage : Nitrogen
Purpose : Gas Manufacturing
Machine Size : Small
Certification : CSA
Technology : Pressure Swing Adsorption
Product Name : Flow Lab Use Compact Nitrogen Generation Plant
More
7yrs

Jinan, Shandong, China

Visit The Store
  • Platform Certification

Product description

Flow Lab Use Compact Nitrogen Generation Plant

Gamma Mini Flow Lab Use Compact Nitrogen Generation System is a small nitrogen generation product designed for many applications, lab use is one of them. It adopts pressure swing adsorption technology. With this technology, oxygen from air is discharged, the rest nitrogen is separated from air as product gas, sending to end user.  This machine has compact structure, quality wheels at bottom, it can be easily moved from one place to another. Its operation noise is very low, suitable for indoor operation.

Mini Lab Nitrogen Gas Plant

1 Lab use mini nitrogen generation system specification:

Item

Specification

Data

Remarks

1

Nitrogen purity

≥99.9%

Oxygen content ≤0.1%

2

Nitrogen flow rate

≥12 L/min

20℃, 101.325Kpa

3

Nitrogen outlet pressure

≥450-620 kPa

See note

4

Power supply

24V

DC

5

Start up time

≤15 minutes

Time to get 99.5% purity

6

Certificates

CE, CSA

customer's property, not distributable

7

Noise

≤72 Db(A)

One meter from equipment

8

Weight

≤160 Kg

With package

9

Dimension

850 x920 x 1100 mm

With package

10

Package

1 carton on 1 plywood pallet

 


2 Lab Use Nitrogen Generator Product Technical Specification

2.1 Compressed air consumption

The generator consumes a maximum of 115 slpm of compressed air to generate the required N2 flow. Air source is not included in this product.

2.2. Air supply pressure

Minimum air supply pressure shall be externally regulated to 600 kPa.  

2.3. Air quality

This Generator is provided with one full set of FESTO filters, the air supplied to the Generator still need to be dry and oil-free.

2.4. N2 output

2.4.1. Quantity of N2 generate: the generator is capable of deliver 25 slpm nitrogen.

2.4.2. Delivery pressure: the generator delivers N2 at a pressure greater than 450 kPa.  

2.4.3. O2 contamination level: O2 level in the N2 stream is not exceed 0.5%, and does not vary from peak to trough by more than 5% of the absolute concentration. 

2.5 Dimensions

With package, the Generator size: 850 mm (Length)x 920 mm (width)x 1100 mm(height).  

2.6 Weight

With package, the Generator weight is less than 160 kg.

2.7 Wheels

The Generator is fitted with 2 fixed wheels at the rear and 2 swivel wheels with brakes at the front

2.8 Connection to power supply

The Generator has a panel mounted connector on the rear panel

• Current capacity at maximum temperature 2.5A<Imax<3.5A ( the power supply is capable of supplying 2.5A nominal)

• Jack plug, 5.5 x 2.5 x 9.5 mm, positive on the centre pin

• Maximum operating voltage at maximum temperature 30VDC.  

• Minimum number of insertions/extractions while maintaining contact resistance specification AND without mechanical failure: > 5000  

• Maximum contact resistance after specified minimum insertions: 30milliohms maximum  

• Insulation resistance: min 100MegaOhms after environmental and durability tests  

• Dielectric withstand Voltage : Min 500V for 60s

• Operating temperature range: -20 deg C to +70 deg C   

2.9 Indicator

The Generator has a pushbutton illuminated switch on the front panel

• Button to be flush mounting or recessed into a bezel to avoid damage

• High corrosion resistance, either plastic or stainless steel body  

• No symbol on button

• Size of button and bezel to be ~ 22mm to 30mm

• Mechanical Endurance : > 1000000 activations without mechanical failure

• Electrical Endurance : > 100000 cycles at maximum current and maintaining maximum specified contact resistance• Action mechanism : push on – push off

• Current handling capability : 4A DC min break, 4A DC min Make, inductive load (double the maximum expected current demand to give good lifetime)

• Maximum DC Working voltage : at least 40V DC

• Illumination type and color : LED, green

• Illumination Operating voltage: 24VDC

• Operating Temperature Range: -20deg C to +70 degC

• Terminal type : either screw terminal or 6.5mm spade type terminals  

2.10. Solenoids

The solenoids on the gas control valves is 24 VDC.

2.11. Operation

2.11.1. Operating cycle

A typical operating cycle for the Generator is 1 start per day and then run for 8 hours per day, which is equivalent to 2000 hours of operation per year. Depending upon the particular site, operating time could be anywhere between 0 and 24 hours per day.  

2.11.2. Operation at shutdown

When the power is turned off, the pressure vessels is maintained in the pressurized state by closing the two exhaust valves.  

2.12. Start up

12.1. Start up time

Start up times means the time from start up to producing qualified nitrogen.

The time to complete start up is less than 15 minutes.  

2.13. Gas connections

The two external gas connections on the Generator, Air In and N2 Out, are constructed from brass and are to suit ¼" (6.35 mm) OD tubing. There are labeling in English next to these connections, [Air In" and [N2 Out", as part of the rating label.

2.14. Environmental requirements

2.14.1. Operating temperatures

The Generator is normally operated within performance specification over the temperature range:

10ºC - 35ºC from 0 – 3000 m, and 10ºC - 25ºC from 3000 – 4500 m

The Generator can operate safely over the temperature range:

5ºC - 35ºC from 0 – 3000 m, and 5ºC - 25ºC from 3000 – 4500 m

2.14.2. Noise level requirements

Noise level from the Generator is less than 72dBa at 1m distance. This is achieved by fitting silencers on the exhaust vents.

2.15. Life Requirements

The Generator can operate with a mean time between failure of 5 years minimum. 