Din rail type A residual current operated relay
Din rail type A residual current operated relay
Din rail type A residual current operated relay
Din rail type A residual current operated relay
Din rail type A residual current operated relay
Din rail type A residual current operated relay

Video

1 / 4

Din rail type A residual current operated relay

  • $160.00

    ≥1 Others

Options:

  • ASJ20-LD1C
  • ASJ20-LD1A
  • ASJ10-LD1C
  • ASJ10-LD1A
  • ASJ10L-LD1A
  • ASJ10L-LD1AC
Send Inquiry
Model No. : ASJ10-LD1A
Brand Name : Acrel
place of origin : China
size : Miniature
Contact load : Low Power
Protect Feature : Sealed
Usage : Protective
Brand Name : Acrel
Theory : Reed Relay
Product Name : Earth Leakage Relay
Type : Multifunction Relay
Load Current : 30a
Application : Widely Used Relay
Name : Current Relay
Function : Leakage Current Protection
Approvals : Eac Ce
Type 2 : Residual Current Relay
Contact Rating : 5a 220vac/28vdc
Protection Type : Line
Model Number : Asj10-Ld1a
Place of origin : Jiangsu, China
More
3yrs

Wuxi, Jiangsu, China

Visit The Store
  • Platform Certification
  • SGS Certification
  • Online Expo

Product description

Din rail type A residual current operated relay

ASJ Series Din rail type A residual current operated relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, Type A residual current operated relay is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below. ASJ Series Multistage adjustable leakage relay of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, Residual current protective device also can provide indirect contact protection against the electric shock risk.

Type
Function
Installation
ASJ20-LD1C
AC type residual current 
Over current alarm 
Rated residual operated current can be set 
Limited non-driving time can be set 
2 relays output(1 NC contact, 1 normal changeover contact) 
With local/remote "test" and "reset" functions
Panel mounted
ASJ20-LD1A
A type residual current measurement 
Current percentage light bar indication(30%, 50%, 70%, TRIP) 
Rated residual operated current
can be set Limited non-driving time can be set 
2 relays output(1 NO contact, 1 normal changeover contact) 
With local/remote/automatic "test" and "reset" functions
Panel mounted
ASJ10-LD1C
AC type residual current 
Over current alarm 
Rated residual operated current can be set 
Limited non-driving time can be set 
2 relays output(1 NC contact, 1 normal changeover contact) 
With local/remote "test" and "reset" functions
35mm Din rail
ASJ10-LD1A
A type residual current measurement 
Current percentage light bar indication(30%, 50%, 70%, TRIP) 
Rated residual operated current
can be set Limited non-driving time can be set 
2 relays output(1 NO contact, 1 normal changeover contact) 
With local/remote/automatic "test" and "reset" functions
35mm Din rail
AASJ10L- LD1A

A type residual current measurement

Rated residual action current can be set
Limit non-driving time can be set
Two sets of relay outputs
The fault alarm of transformer can be set
Warning value can be set
Return value can be set
With on-site, remote "test" , "reset" function
25 event records;
LCD screen

RS485 modbus-RTU communication

35mm Din rail


Residual current protective device

Dimensions
Multistage adjustable leakage relay
Packing & Delivery
Type A residual current operated relay
Company Profile
Type A residual current operated relay
Acrel Electric Co., Ltd. [Stock Code: 300286.SZ]
Founded in 2003, one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users. Substation automation system, power quality management system, energy management system, electrical fire monitoring system, IT distribution system for medical locations, precise distribution management system, FEPS power supply monitoring system, fire emergency lighting and evacuate indicating system, smart lighting control system and electric vehicle charging system.
FAQ

Q: Are you trading company or manufacturer ?

A: We are factory. Warmly welcome you to visit and investigate our factory.

Q: How long is your delivery time?

A: Generally it is 3-10 days if the goods are in stock. or it is 10-20 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for lower price. If you place the order, all or part of the sample charge will be deducted from the goods. Please contact us.

Q: What is your terms of payment ?

A: Usually, 100%TT in advance. If you have projects for another payment terms, please feel free to contact us.

Video

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628