Model No. : CP-06
Brand Name :
10yrs

Zhangzhou, Fujian, China

Visit The Store

Product description

  • Small jaw size: Ø 6.5mm
  • Connected to oscilloscopes or " mV" range digital multiple meter
  • Low battery indication
  • 1KHz, 10kHz (±3dB)
  • DC/AC current:
    • 400mA, accuracy: 2.0% + 0.01A
    • 4A, accuracy: 1.0% + 0.02A
    • 40A, accuracy: 1.0% + 0.1A
  • Output sensitivity: 1mA/1mV(400mA),10mA/1mV(4A),0.1A/1mV(40A)
  • Minimum resolution: 0.1mA
  • Power source: AA size 1.5V x 2 batteries
  • Weight: 200g (approximately)
  • 400mA, accuracy: 2.0% + 0.01A
  • 4A, accuracy: 1.0% + 0.02A
  • 40A, accuracy: 1.0% + 0.1A