Clamp Meter with 0.1 to 240A Measuring Range and Transformation Ratio of 1,000:1
Clamp Meter with 0.1 to 240A Measuring Range and Transformation Ratio of 1,000:1
Clamp Meter with 0.1 to 240A Measuring Range and Transformation Ratio of 1,000:1

1 / 1

Clamp Meter with 0.1 to 240A Measuring Range and Transformation Ratio of 1,000:1

Get Latest Price
Send Inquiry
Model No. : KT- 313 Current Probe
Brand Name :
10yrs

Zhangzhou, Fujian, China

Visit The Store

Product description

  • Electrical:
    • Nominal current: 200A
    • Output signal: 1mA/A (100mA at 100A AC)
    • Accuracy:
      • 200A range
      • 0.1 to 1A: 2% of reading ±0.02mA
      • 1 to 80A: 1% of reading ±0.02mA
      • 80 to 100A: 2% of reading ±0.1mA
      • 100 to 150A: 2.5% of reading ±0.5mA
      • 150 to 200A: not specified
    • Accuracy with phase shift:
      • 0.1 to 1A: not specified
      • 1 to 20A: ≤3.0°
      • 20 to 80A: ≤2.0°
      • 80 to 150A: ≤2.5°
    • Frequency range: 40Hz to 2kHz (10kHz)
    • Working/common mode voltage: 600V RMS
    • Output termination: 5ft lead
  • Mechanical:
    • Operating temperature: 14 to 131°F (-10 to 55°C)
    • Storage temperature: -40 to 158°F (-40 to 70°C)
    • Operating relative humidity: 10 to 35°C, 85% RH (withoutroll-off above 35°C)
  • Note:
    • Connect to 1Ω load ampere meter
    • If AC voltage output is required, please connect a 1Ωresistance to the two terminals
  • Nominal current: 200A
  • Output signal: 1mA/A (100mA at 100A AC)
  • Accuracy:
    • 200A range
    • 0.1 to 1A: 2% of reading ±0.02mA
    • 1 to 80A: 1% of reading ±0.02mA
    • 80 to 100A: 2% of reading ±0.1mA
    • 100 to 150A: 2.5% of reading ±0.5mA
    • 150 to 200A: not specified
  • Accuracy with phase shift:
    • 0.1 to 1A: not specified
    • 1 to 20A: ≤3.0°
    • 20 to 80A: ≤2.0°
    • 80 to 150A: ≤2.5°
  • Frequency range: 40Hz to 2kHz (10kHz)
  • Working/common mode voltage: 600V RMS
  • Output termination: 5ft lead
  • 200A range
  • 0.1 to 1A: 2% of reading ±0.02mA
  • 1 to 80A: 1% of reading ±0.02mA
  • 80 to 100A: 2% of reading ±0.1mA
  • 100 to 150A: 2.5% of reading ±0.5mA
  • 150 to 200A: not specified
  • 0.1 to 1A: not specified
  • 1 to 20A: ≤3.0°
  • 20 to 80A: ≤2.0°
  • 80 to 150A: ≤2.5°
  • Operating temperature: 14 to 131°F (-10 to 55°C)
  • Storage temperature: -40 to 158°F (-40 to 70°C)
  • Operating relative humidity: 10 to 35°C, 85% RH (withoutroll-off above 35°C)
  • Connect to 1Ω load ampere meter
  • If AC voltage output is required, please connect a 1Ωresistance to the two terminals