Model No. : CL-130KS
Brand Name : ChangLong

Product description

Silent Generator set CHANGLONG low noise generator is a new series of products with advanced technology, the products comply  with GB/T2820-1997 or GB12786-91 national standards, and has mass production. The overall design of the gen-set is compact structure, small volume, novel and beautiful appearance.  The use of high-end sound absorption and noise reduction material and efficient multi-channel intake  and exhaust noise reduction, into the exhaust channel, large impedance composite muffler,  in ensuring Significantly improved low noise performance adequate power unit performance under. Widely used in telecommunications, hotels, buildings, places of entertainment, hospitals,shopping malls,  industrial and mining enterprises and other areas with strict requirements on environmental noise,  as the common or standby power supply. Design Standards                                                                                 Factory Inspection 1,The designs and the productions are in conformity with                        • Inspection items.  2,China Compulsory Certification (CCC)                                                      • Protection devices working test.  3,GB/T19001-2008 / ISO9001:2008                                                               • Starting ability in normal temperature. Design Conditions                                                                               • 50% rated power load moment capability. The designs and the products are in conformity with:                                • Voltage deviation and speed variation: 0%,  • Installation place:Outdoors or indoors (well ventilated)                             25%, 50%, 75%, 100%, 110% Load.  • Humidity: Less than 80%.                                                                              Painting Process • Altitude:Below than one thousand (1000) meters                                     • Painting process specifications and colors  above sea Level.                                                                                                   are based on the manufacturer’s standard.                                                                                                                                • The customer could also choose the color                                                                                                                                    which the manufacturer offers. ChangLong Silent Diesel Genset Description of Commodity as follows

• Silent Genset Model .......................CL-130KS

• Engine Model...............................R6105AZLD

• Brushless Generator Model..............TFW-274E

• Controller Model..........................HGM6120UC

• Prime Power ………….................130KVA/104KW

• Standby Power …….................140KVA/112KW

• Main Circuit breaker..................3-Phase 4-wire

• Voltage........................................380V/220V

• Speed...........................................1500rpm

• Frequency......................................50Hz

• Rating Current...............................187A

• Tank Capacity ……..........................300L

• Silent genset, the nois..................73dBA@7m

• Rotate speed governor.....Machanical governing

• Excitation System.........................Self excited

• Outside Refueling

• Outside Watering

• Key switch

• Emergency stop switch

• 2x12V battery

• Powder coated canopy

• 50°C radiator.

• Steel base frame with forks lots.

• Dry type air filter

• Base fuel tank

• Vibration isolators between the

engine/alternator and base frame.

• Operator’s Manual / Parts Manual / Specifications

• Dimensions L×W×H: 2900x1200x1600mm

• Dry Weigh (approx.) …...2400kg

Diesel Engine

• Engine Brand ...................ChangLongEngine

• Engine Model …………….................R6105AZLD

• Engine Continuous Power .................121kW

• Engine Maximum Power.....................134kW

• Engine Number of Cylinders .........6 Cylinders

• Engine Bore / Stroke............105mm/130mm

• Engine Displacement…………….............6.89L

• Engine Speed…………….....................1500rpm

• Engine Start the motor....................24V

• Engine Fuel pump.........Machanical governing

• Engine Type of Fuel ………………........Diesel

• Engine oil……………….……...............15W40-CF4

• Engine Cooling System ............Water cooled

• Engine Fan …………………………...........Pusher

• Engine Type of injection..........Direct injection

• Engine Intake System……..........Turbocharged 

• Engine Fuel Consumption............≤224g/kW.h

Brushless Generator

• Generator Brand............................ChangLong

• Generator Model.............................TFW-274E

• Generator Continuous Power ......130KVA/104kW

• Generator Maximum Power..........140KVA/112kW

• Generator Speed…………..............1500rpm

• Generator Frequency.........................50Hz

• Generator Voltage...........................380V / 220V

• Generator Rating Current.........................187A

• Generator Power Factor…............................0.8

• Generator Windings.....................100% copper

• Generator Altitude.................................≤1000m

• Generator Exciter ………..................Brushless

• Generator Insulation Class......................…...H

• Generator Protection Class.......................IP23

• Generator Voltage Regulation.................±1.0%

• Telephone Interference ……...THF<2%;TIF<50

Total harmonic.TGH / THCat no load<1.5%on load < 5%

Diesel Generator Set Control System  HGM6120UC is an automatic mains failure control module. Itis used to monitor the mains supply  and automatically startand stop the engine.  The module indicates the operational status and fault conditions, automatically shutting down  theengine and indicating engine failure on the LCD. • Microprocessor control, with high stability and  credibility • Mains supply and generator operation monitoring • Indicating operation status and fault conditions • Multiple protections; multiple parameters display, like pressure, temp, ect. • Manual and automatic work mode selectable • Real time clock for time and date display, overall runtimedisplay, 99 log entries • Overall power output display • Integral speed/frequency detecting, telling status ofstart, rated operation, overspeed • Communication with PC via RS485 OR RS232 interface,using MODBUS protocol CHANGLONG dual power switch cabinet ATS automatically switch cabinet by the automatic transfer switch and have mains failure detection (AMF)  feature of the unit control the composition of the screen. When the mains fails, ATS switch cabinet full logic  control system automatically starts the generator set and transfer the load to the generator set; and when  the utility power is restored, the load is automatically switched to the mains. Powerful engines 1. Adopts word-famous engines, with noise and low emission. 2. Rugged structure ensures lowest vibration. 3. Common rail system: (for some models) significantly lowers the combustion temperature, and leads to  cleaner exhaust. 4. For the turbocharged machines, the carbon dioxide (CO2) emission is reduced.  Easy to operate (Control system)   1. Micro-processor cored digital system. 2. Multiple languages, automatic control. 3. Connected with the mains through ATS, which can help realized automatic transfer between the mains and  the generators. Also, multiple generators can be paralleled for bigger power needs. Convenient refueling and watering installations 1. Outer filling fuel port. 2. 8-12 hours base fuel tank in soundproof generator sets prevents against leakage and fuel spray when  cleaning the interior. The fuel tank abides by European environment protection standards. 3. Drainage outlet. 4. Water feeder is located on top of the canopy. Convenient Connection 1. Terminal connection lugs(L1,L2,L3 and LN)make connection and wiring more simple and well-ordered. 2. Emergency stop provides convenient operation in emergent situation and when serving. ChangLong Diesel Genset 3-Phase 4-wire Voltage 380V / 220V - 50HZ - 1500rpm 

ChangLong Diesel Genset

ChangLong Engine

ChangLong Brushless Generator

Silent Genset

Model

Prime 

Power

Standby 

Power

Engine Model

Engine

Power

Cylin

ders

Consu

mption

Generator 

Model

Continuous 

Power

Maximum 

Power

KVA/KW

KVA/KW

KW

L

g/kW.h

KVA/KW

KVA/KW

CL-60RS

60/48

70/56

ZH4105ZD

56/62

4

≤218

TFW-224E

60/48

70/56

CL-60RS

60/48

70/56

R4105ZD

56/62

4

≤218

TFW-224E

60/48

70/56

CL-75RS

75/60

80/64

R4105AZLD

66/73

4

≤218

TFW-224F

75/60

80/64

CL-75RS

75/60

80/64

R4108ZD

66/73

4

≤225

TFW-224F

75/60

80/64

CL-85RS

85/68

95/76

R6105ZD

84/93

6

≤224

TFW-224G

85/68

95/76

CL-100RS

100/80

110/88

R6105ZD

84/93

6

≤224

TFW-274C

100/80

110/88

CL-120RS

120/96

130/104

R6105AZD

101/112

6

≤224

TFW-274D

120/96

130/104

CL-130RS

130/104

140/112

R6105AZLD

121/134

6

≤224

TFW-274E

130/104

140/112

CL-150RS

150/120

160/128

R6105IZLD

132/151

6

≤225

TFW-274F

150/120

160/128

CL-160RS

160/128

180/144

R6105IZLD

151/165

6

≤225

TFW-274F

160/128

180/144

1. Brand-new engine, with start motor. 2. Brand new brushless alternator, single bearing, flange connection, IP23, H insulation class, with AVR. 3. Heavy duty steel channel base frame. 4. Heavy duty industrial type silencer with flexible bellow. 5. Vibration damping supports between Engine/Alternator and base frame. 6. Radiator with safety guard. 7. Automatic strat control panel, Smartgen 6120 model as standard supply. 8. High capacity lead acid battery C/W battery cables. 9. 3-pole output circuit breaker. 10.Below 500KW, skid-mounted bottom fuel tank for 8hrs full load as standard supply. Above 500KW,  storage fuel tank is provided at extra cost. 11. Standrad tool kits and complete operation/maintenance/manuals to Engine/Alternator/Control panel, etc. 12. Optional supply: a) Remote start / Auto maius failure(AMF) / ATS(automatic transfer switch) control panel,  b) Soundproof / Weatherproof canopy, c) Mobile trailer, d) Auto load sharing, synchronizing panel and load  sharing. The features of  CHANGLONG trailer type mobile power gen-set. 1. Appearance, using movable hooks, to flexible, ensuring driving safety.
2. Silent canopy box with observation windows, can be observed at a glance the operation of the unit. Both  sides of the door, easy to operate and maintain. 3. canopy box sealing, rain, dust, theft, use of safety.
4. Trailer chassis for the overall frame structure, installing leaf spring damping.
5. Taillight with a seven-hole plugs series, steering and brake lamp.
6. Four trailers equipped with air brake system, brake tractor synchronized to ensure driving safety.
7. To ensure the stability of the power car operation, the two-wheeled trailers equipped with four  mechanical support devices. 8. There explosion inside ceiling lamp, and is equipped with a working power outlet, etc., to facilitate staff to  operate.
9. Fire Truck equipped with fire extinguishers, make sure the trailer safety.
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628