Boots & Gloves Dielectric Test Set
Boots & Gloves Dielectric Test Set
Boots & Gloves Dielectric Test Set

1 / 1

Boots & Gloves Dielectric Test Set

Get Latest Price
Send Inquiry
Model No. : HMJS-3 (0-50KV)
Brand Name :

Product description

Product Description

I. Product introduction

We designed & produced Model no.HMJS-3 insulating boots ( gloves ) dielectric test 
equipment based on charged protective equipment insulation test procedures, and 
compliance with the majority of users opinions. The product has an effective solution for the 
past irregular testing method, thereby simplifying the testing procedures, improving the test 
speed. A more reliable identification of insulating boots ( gloves ) leakage current, 
insulation aging, power frequency withstand voltage and other parameters. To protect 
operator safety, so it is the ideal insulation boots ( gloves ) and special equipment. 

Its main features: it can be tested simultaneously 3 pair of insulating boots ( gloves ), and it 
can read leakage current of each glove to judge unqualified insulating boots ( gloves ); 
structure bottom assembly casters, so it can freely move.

II. Working principle

0~220V power supply, regulating power frequency voltage withstand test according to the
 principle of electromagnetic induction of test transformer, to make transformer output 
0~1-0KV high voltage to each electrode, so that insulating boots ( gloves ) obtain the test 
voltage specified. According to the insulating boots ( gloves ) test procedures, read, record 
test parameters. 


Boots & Gloves Dielectric Test Set

Boots & Gloves Dielectric Test Set
           
III. Structure design

The product is divided into 3 parts:
1.HMJS-3 type insulating boots ( gloves ) dielectric test device test trolley, trolley moving 
bracket, sinks, electrode rod support;

2.HMJS-3 type insulating boots ( gloves )dielectric test device test bench, insulating boots 
( gloves ) pressure test device test bench is composed of a transformer and control unit.
  
Trolley equipment includes:                 
1.Moving bracket; 
2.Sink;
3 Insulating rod
4.Electrode rod support;
5.High voltage terminal;
6.Leakage measurement terminal

Boots & Gloves Dielectric Test Set

3.Transformer 3KVA/50KV
 1) Capacity:3KVA 
 2) Input Voltage:AC200V 50Hz
 3Power Input:15A
 4) Output Voltage:AC50KV  
 5Power Output:AC60mA      
                 

IV.Main technical parameters

1. Input voltage: 220V,50HZ
2. output voltage:0-50KV
3.Capacitance: 3KVA
4. Test number : 3 pairs each 
5.Weight: Insulation test trolley with protective tools: 80KG
          Power frequency withstand voltage test bench: 70KG
                                Transformer (5kva/50kv): 45kgs 

Spe.  kVA Low Voltage side High voltage side Ratio C/60min Resistance
%
Unload
%
 Weight
(kg)
V A  kV mA
1.5/50 1.5 200 7.5 50 30 500 50 10 <4 19.5
3/50 3 200 15 50 60 500 50 10 <4 27
5/50 5 200 25 50 100 500 50 10 <4 52
10/50 10 200 50 50 200 500 50 10 <4 80
15/50 15 400 37.5 50 300 500 50 8 <4 120
20/50 20 400 50 50 400 500 50 8 <4 140
30/50 30 400 75 50 600 500 50 8 <4 155
50/50 50 400 125 50 1000 500 50 8 <4 184
 5/100 5 200  25 100  50  500  50 10 <4  110
Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628