Product description
Maximal continuous charging and discharging current: 2A
Over-current detection current: 2.5 to 3.5A
Charging voltage CC/CV: Li-ion/Li-polymer (4.2V/cell)
Balance voltage for single cell
Current balance current for single cell
Current consumption: ≤10 μ A
Maximal continuous charging and discharging current: 2A
Over-charge protection and over-charge detection voltage: 4.30 ±0.05V
Over charge detection delay time: 0.7S-1.3S
Over-charge release voltage: 4.1 ±0.05V
Over-discharge protection and over discharge detection voltage: 2.40 ±0.01V
Over-discharge detection delay time: 40-100mS
Over-discharge release voltage: 3.0 ±0.1V
Over-current protection and over-current detection voltage: 0.15 ±0.03V
Over-current detection current: 3.0 ±0.5A
Detection delay time: 8-16ms
Release condition: cut load
Short-protection detection condition exterior short-circuit
Detection delay time: 230-500μs
Release condition cut load
Resistance protection circuitry: ≤60mΩ
Operating temperature range: -40 to +85°C
Storage temperature range: -40 to +125°C