Number | Trouble | Cause | Shooting |
1 | Motor of Barrier does not work | 1,No power supply 2,Break fuse 3,Motor is damaged | 1,Check power supply 2,Change fuse 3,Change the motor |
2 | Barrier can open but can not close | 1,Photocell is not connected properly 2,Photocell beam is block off 3,Photocell is broken | 1,Connect the photocell 2,Clear out obstacle 3,Change a new device |
3 | Barroer can open (close) but can not close (open) | 1,Position of limit switch is not correct 2,Limit switch is damaged | 1,Adjust position 2,Change limit switch |
4 | Barrier can not locate accurately | 1,Distance of limit switch is too large 2,Limit switch is wrong 3,Magnetic-stell’s position is wrong | 1,Adjust position of limit switch 2,Change limit switch 3,Re-adjust the position |
5 | Release device of Barrier is doesn’t work | 1,Operating handle is broken 2,Worm gears are jammed | 1,Change the handle 2,Rotate the pinion |
6 | Push the “OPEN” button but the Barrier gate close | Whether “+MOTOR-” wires are connected wrong | Connect correctly according to wiring diagram |
7 | Motor of Barrier can work but boom can not work | Compression spring of clutch is dead | Change the spring |