Aurora4000 UV-NIR Spectrometer     Features:   Up to 0.02nm(FWHM) optical resolution Convenient operation Customized wavelength range and resolution Fit various applications Support download for Spectral Analysis 5.0     Applications: Laser spectral analysis Fluorescence spectral analysis Raman spectral analysis Film thickness measurement Chemical research Reflectivity/transmittance measurement Biological cell analysis LED analysis Absorbance measurement   Available Model:  

Model

Spectral range

Aurora4000 General series

GE 350-1100nm

GE 200-1100nm

GE Raman

Aurora4000 External Triggering series

TG 350-1100nm

TG 200-1100nm

      Wavelength Customizable Spectrometer:  

Model

Entrance aperture

Spectral range

Optical resolution

Aurora4000

10 μm

200-300 nm 0.17
200-347 nm 0.14
226-369 nm 0.18
310-404 nm 0.16
319-455 nm 0.13
400-480 nm 0.08
423-547 nm 0.12
480-568 nm 0.12
546-653 nm 0.12
568-634 nm 0.09
654-754 nm 0.10
748-837 nm 0.23
794-876 nm 0.24
      Standard Specifications:  

Detector

Detector

Toshiba TCD1304DG linear CCD array

Wavelength range

200-1100nm

Pixels

3648 pixels

Pixel size

8um*200um

Sensitivity

130 photons/count at 400nm
 60 photons/count at 600nm

 

Spectrometer

Dimensions (mm)

149*105*46

Weight (g)

840

Optical resolution

<0.75nm FWHM

Signal-to-noise ratio

300:1 (at full signal)

Dark noise

12RMS counts

Dynamic range

2*10ˆ9(system);1300:1 for a single acquisition

Integration time

4ms-10s

Stray light

<0.05%@600nm; <0.10%@435nm

Corrected linearity

>99.8%

 

Optical Bench

Design

f/4, Symmetrical crossed Czerny-Turner

Focal length

101.6mm input and output

Entrance aperture (um)

5,10,25,50,100 or 200

Grating

A variety of different grating, ultraviolet and infrared

Fiber optic connector

SMA905 to 0.22 numerical aperture single-strand fiber

 

Electronics

Power consumption

450mA@5VDC

Trigger mode

4 species

Data transfer speed

Full scans into memory every 4 milliseconds with USB 2.0; every 18 milliseconds with USB 1.1

Inputs/outputs

5 inputs and 5 outputs (opto-isolator inputs/outputs)

Analog channels

One 12 analog input one 12 analog output

Connector

30-pin connector

                                              Aurora4000 spectrometer application device  
Laser spectrum

 

 

 

 
   
Nd:YAG fluorescence spectrum

 

                                                                                   

 

 

                                                                           
     
Reflection chroma test
                                                                  Application area                         LED analysis                                      Bioscience application                                        R/T measurement                                          Plasma spectral analysis                                                                         Accessories    