Aluminum Electrolytic Capacitors with 10 to 100 and 160 to 400V Rated Voltage
Aluminum Electrolytic Capacitors with 10 to 100 and 160 to 400V Rated Voltage
Aluminum Electrolytic Capacitors with 10 to 100 and 160 to 400V Rated Voltage

1 / 1

Aluminum Electrolytic Capacitors with 10 to 100 and 160 to 400V Rated Voltage

Get Latest Price
Send Inquiry
Model No. : TMCE22=.=-.....
Brand Name :
10yrs

Shenzhen, Guangdong, China

Visit The Store

Product description

  • Features:
    • Rated voltage range: 10 to 100 and 160 to 400V
    • Operating temperature range: -40 to 105°C and -25 to 105°C
    • Capacitance tolerance (25°C, 120Hz): 0 to 20%
    • Leakage current: 5mA, whichever is smaller (at 25°C, after 5 minutes)
    • C: nominal capacitance
    • V: rated voltage
    • Temperature stability (120Hz): capacitance change
    • 10 to 100V DC: capacitance at -40°C shall not be less than 60% of the 25°C value
    • 160 to 400V DC: capacitance at -25°C shall not be less than 70% of the 25°C value
    • Load lifespan (105°C): 2,000 hours
    • Leakage current: not more than the specified value
    • Capacitance change: within ± 20% of the initial value
    • Dissipation factor: not more than 200% of the specified value
    • Shelf lifespan (105°C): 2,000 hours
    • Leakage current: not more than the specified value
    • Capacitance change: within ± 20% of the initial value
    • Dissipation factor: not more than 200% of the specified value
    • After-test: UR to be applied for 60 minutes, 24 to 48 hours before measurement
  • Rated voltage range: 10 to 100 and 160 to 400V
  • Operating temperature range: -40 to 105°C and -25 to 105°C
  • Capacitance tolerance (25°C, 120Hz): 0 to 20%
  • Leakage current: 5mA, whichever is smaller (at 25°C, after 5 minutes)
  • C: nominal capacitance
  • V: rated voltage
  • Temperature stability (120Hz): capacitance change
  • 10 to 100V DC: capacitance at -40°C shall not be less than 60% of the 25°C value
  • 160 to 400V DC: capacitance at -25°C shall not be less than 70% of the 25°C value
  • Load lifespan (105°C): 2,000 hours
  • Leakage current: not more than the specified value
  • Capacitance change: within ± 20% of the initial value
  • Dissipation factor: not more than 200% of the specified value
  • Shelf lifespan (105°C): 2,000 hours
  • Leakage current: not more than the specified value
  • Capacitance change: within ± 20% of the initial value
  • Dissipation factor: not more than 200% of the specified value
  • After-test: UR to be applied for 60 minutes, 24 to 48 hours before measurement