Air Cooled Ducted Split Unit for Fresh Air
Air Cooled Ducted Split Unit for Fresh Air
Air Cooled Ducted Split Unit for Fresh Air
Air Cooled Ducted Split Unit for Fresh Air
Air Cooled Ducted Split Unit for Fresh Air

Video

1 / 3

Air Cooled Ducted Split Unit for Fresh Air

$1499.00 ~ $1499.00 / Set/Sets
Send Inquiry
Model No. : AA()
Brand Name : Amrta or OEM
Type : Cabinet Air Conditioner
Air Tube Material : Galvanized Sheet
Corrosion Durability : Ultrahigh
Noise Level : Ultra Low
Mounting : Split
Lifetime : 10~15 years
Certification : CE
Condition : New
Electric Parts : Schneider Brand
Operating Voltage : 380-415, 440, 460, 50/60Hz
Application Fields : Supermarket, Hospital, Pharmaceutical And Building
Capacity : 20kw-104kw
Power Source : Electrical
Power Type : AC
Refrigerant : R22/R407c/R410A/R134A
Compressor : Copelan/Danofss/Pansonic/Daikin Brand
Filter Type : Pre, Medium And HEPA(Optional)
Cooling/Heating : Cooling/Heating
More
6yrs

Jinan, Shandong, China

Visit The Store
  • Platform Certification
  • Online Expo

Product description

Ducted Split Unit is a high efficient and energy saving air conditioning system that applicable to hotel, supermarket, office building, factory, entertainment lieu,etc. It combines comfort of central air conditioning with flexibility of split unit. The new design considers the features of modern building, spreading cooling / heating air to everywhere of the room equally, to form zero temperature difference. This model occupies less space, integrating duct and indoor decoration, become the upgrade production of central air conditioner and traditional commercial air conditioning.


Application areas
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.


Why this choice?
High efficiency: Adopts famous brand compressor, multi-level adjustment, high efficiency anti-corrosion hydrophilic aluminum foil, which make the efficiency up to 30%.
Extraordinary performance: Adopts well-know brand opponents, such as EMERSON, SPORLAN, DANFOSS brand etc.
Intelligent control: Micro computer control, cooling, heating, auto, ventilation can be free switching.


Characteristics
11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.
Split installation, connected by means of flare/welding coupling. 

Easy operation line controller:  
• Cooling/Heating/Fan/Auto
• Error indication
• Timing On/Off
• Multi safety protection 
• High/low pressure protection
• Overheat protection
• Current overload protection
• Phase sequence relay
• Time delay and antifreeze switch

Optional
• Additional electric heater on indoor unit
• Additional heating coil on indoor unit


Technical Data

Model

Unit

AA20

AA25

AA32

AA36

AA42

AA48

Nominal cooling capacity*

kW

19.5

24.8

31.2

35.6

41.3

47.4

Nominal heating capacity**

kW

22.6

28.9

35.8

40.8

46.9

54.4

Connection

 

 

 

 

 

 

 

Method

/

Flare

Flare

Flare

Welding

Welding

Welding

Liquid pipe diameter

¢mm

9.52x2

12.7x2

12.7x2

15.88x1

15.88/12.7

15.88/12.7

Gas pipe diameter

¢mm

15.88x2

19.05x2

19.05x2

28x1

28/19.05

28/19.05

Power supply

/

230V/3N/60Hz

 

 

 

 

 

 

Outdoor unit

Compressor

 

Qty/refrigerant circuit

Nr.

2/2

2/2

2/2

1/1

2/2

2/2

Cooling power input*

kW

7.2

9.3

11.8

12.8

15.1

17.9

Heating power input**

kW

7.13

9.21

11.68

12.67

14.95

17.72

Energy adjustment

%

50-100

50-100

50-100

0-100

40-60-100

33-66-100

Axial fans

 

Quantity

Nr.

1

1

1

1

2

2

Airflow

m3/h

9400

9400

12500

14200

18800

18800

Sound pressure level***

dB(A)

67

67

68

70

71

71

Net weight

kg

170

180

220

280

260

280

 

 

 

Indoor unit

Centrifugal fans

 

 

 

 

 

 

 

Quantity

Nr.

2

2

2

2

2

2

Airflow

m3/h

3500

4500

5650

6450

7400

8550

ESP

Pa

120

100

150

130

180

200

Sound pressure level***

dB(A)

64

64

66

66

68

68

Net weight

kg

90

100

150

160

180

200

Additional electric heater****

kW

2×3

2×4

2×5

2×6

2×6

2×8

Additional heating coil****

kW

22.2

28.4

35.1

40.0

46.0

53.3


Model

Unit

AA52

AA62

AA72

AA88

AA104

Nominal cooling capacity*

kW

51.3

63.3

71.3

87.9

103.7

Nominal heating capacity**

kW

58.9

72.6

81.9

100.0

115.8

Connection

 

 

 

 

 

 

Method

/

Welding

Welding

Welding

Welding

Welding

Liquid pipe diameter

¢mm

15.88/12.7

15.88×2

15.88×2

15.88×2

19.05×2

Gas pipe diameter

¢mm

28/19.05

28×2

28×2

28×2

35×2

Power supply

/

230V/3N/60Hz

 

 

 

 

 

 

 

Outdoor unit

Compressor

 

Qty/refrigerant circuit

Nr.

2/2

2/2

2/2

2/2

2/2

Cooling power input*

kW

18.4

23.1

26.6

28.1

39.3

Heating power input**

kW

18.22

22.87

26.33

27.82

38.91

Energy adjustment

%

30-70-100

50-100

50-100

50-100

50-100

Axial fans

 

Quantity

Nr.

2

2

2

2

2

Airflow

m3/h

21500

26500

29880

36500

43500

Sound pressure level***

dB(A)

71

71

71

71

71

Net weight

kg

330

460

460

780

800

 

 

 

 

Indoor unit

Centrifugal fans

 

 

 

 

 

 

Quantity

Nr.

2

2

2

2

2

Airflow

m3/h

9250

11450

12900

14800

17100

ESP

Pa

200

300

300

280

500

Sound pressure level***

dB(A)

68

68

69

69

70

Net weight

kg

220

230

300

320

400

Additional electric heater****

kW

2×8

2×10

2×10

2×12

2×14

Additional heating coil****

kW

57.8

71.2

80.3

98.0

113.5

Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7°C / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.

**** Optional as request.

Rooftop Split Unit


Video

Send Inquiry

Product Alert

Subscribe to your interested keywords. We will send freely the latest and hottest products to your Inbox. Don't miss any trade information.

版权所有 © 宁波全贸信息技术有限公司 浙ICP备12012821号-1 浙B2-20200628