aerial bundled conductors 3*50+54.6
aerial bundled conductors 3*50+54.6
aerial bundled conductors 3*50+54.6

1 / 1

aerial bundled conductors 3*50+54.6

Get Latest Price
Send Inquiry
Model No. : 3*50+54.6
Brand Name : GHCABLE

Product description

Specifications good quality and price

short time delivery

  AERIAL BUNDLED CONDUCTORS   With or without neutral messenger   Câble torsadé BT de branchement aérien       CONSTRUCTION   1 – Conductor: - Neutral: Stranded aluminum alloy - Phases: Stranded aluminum 2 – Insulation: Black XLPE 3 – Optional: 1, 2, or 3 public lighting Aluminum conductors insulated with Black XLPE   CHARACTERISTICS Rated voltage: 0.6/1 kV Conductors: - Neutral: Stranded Aluminum alloy class 2 with cross section 54.6mm2 or 70mm2 and minimal breaking load respectively 1660 and 2000 daN. - Phases: Stranded Aluminum class 2 - Public lighting: Stranded Aluminum class 2 Max. Permissible temperature:    90°C Operating    250°C Short-circuit Allowed Bending Radius: Not less than 4 times of overall cable diameter (D) when D is less than 25mm; Not less than 4D when D is equal to and above 25mm. Conductor identification: - Neutral: Black with identification marking - Phases: Black marked with numeral 1, 2, 3. - Public lighting: EP1, EP2 is printed and embossed on each conductor, EP3 if three conductors are required.   APPLICATION These cables are extensively used in overhead electric power transmission and distribution lines. These cables are NOT ALLOWED to be buried, even in conduits.   PRODUCT LIST Without Neutral Messenger  

*   2 x 16 mm2

* 2 x 16 mm2 + 2 x 1.5 mm2

*   2 x 25 mm2

* 2 x 25 mm2 + 2 x 1.5 mm2

   2 x 35 mm2

   2 x 35 mm2 + 2 x 1.5 mm2

   2 x 50 mm2

   2 x 50 mm2 + 2 x 1.5 mm2

*   4 x 16 mm2

* 4 x 16 mm2 + 2 x 1.5 mm2

   4 x 25 mm2

* 4 x 25 mm2 + 2 x 1.5 mm2

   4 x 35 mm2

   4 x 35 mm2 + 2 x 1.5 mm2

With Neutral Messenger  

1 x 54.6 mm2 + 3 x 25 mm2 + K x 16 mm2

*   1 x 54.6 mm2 + 3 x 35 mm2 + K x 16 mm2

1 x 54.6 mm2 + 3 x 50 mm2 + K x 16 mm2

1 x 54.6 mm2 + 3 x 70 mm2 + K x 16 mm2

1 x 54.6 mm2 + 3 x 70 mm2 + K x 25 mm2

*   1 x 70 mm2+ 3 x 70 mm2+ K x 16 mm2

1 x 70 mm2+ 3 x 95 mm2+ K x 16 mm2

1 x 70 mm2+ 3 x 120 mm2 + K x 16 mm2

*   1 x 70 mm2+ 3 x 120 mm2+ K x 16 mm2

1 x 95 mm2+ 3 x 120 mm2+ K x 16 mm2

1 x 95 mm2+ 3 x 150 mm2+ K x 16 mm2

  K represents the number of public lighting lines, K cab be 0, 1, 2 or 3.   Technical Characteristics Based on Standard UTE NF C 33-209  

Designation

Conductor

Average thickness of insulation (XLPE)

Insulated conductor

Conductor type

Nominal area

Number of wires

Max. D.C. resistance at 20oC

Diameter of conductor

Min. breaking
load

Overall diameter

Min.

Max.

Min.

Max.

mm2

No.

Ω/km

mm

mm

kN

mm

mm

mm

Phase or neutral non- messenger or street lighting

16

7

1.91

4.6

5.1

1.9

1.2

7

7.8

25

7

1.2

5.8

6.3

3

1.4

8.6

9.4

35

7

0.868

6.8

7.3

-

1.6

10

10.9

50

7

0.641

7.9

8.4

-

1.6

11.1

12

70

12

0.443

9.7

10.2

-

1.8

13.3

14.2

95

19

0.32

11

12

-

1.8

14.6

15.7

120

19

0.253

12

13.1

-

1.8

15.6

16.7

150

19

0.206

13.9

15

-

1.7

17.3

18.6

Neutral messenger

54.6

7

0.63

9.2

9.6

16.6

1.6

12.3

13

70

7

0.5

10

10.2

20.5

1.5

12.9

13.6

95

19

0.343

12.2

12.9

27.5

1.6

15.3

16.3

       
Send Inquiry