Specifications 1.AC DC dell desktop power supply
2.UL,FCC,CE
3.competitive price
4.OEM,ODM
5.Output voltage:5V 12V 24V 48V
5Vdc 12Vdc 24Vdc 48Vdc AC DC dell desktop power supply/ Adapter,laptop adapter,power adapter,desktop adapter 1.1Input Voltage Table 1: Lists the AC input operating voltage range. The power shall work normally and meet all electrical requirements throughout this range. Table 1: AC Input Voltage Limitations
Minimum | Nominal | Maximum |
100Vac | 110Vac/220Vac | 240Vac |
1.2Input Frequency Table 2: List the AC input operating frequency range. The power shall work normally and meet all electrical requirements throughout this range. Table 2: AC Input Frequency Limitations
Minimum | Nominal | Maximum |
47Hz | 50Hz/60Hz | 63Hz |
1.3 Inrush Current Peak inrush current shall be limited to 30A of rated input voltage and cold start at 25 degrees C, and shall not result in a permanent damage of the power supply under any conditions of load and input voltage as specified at any input voltage as specified in table 1. 1.4 Input Current Limiting The input current should be less than 1.0A, under minimum AC input and full load. 1.5 Efficiency The power supply efficiency shall be greater than 75% under rated input voltage. It will be measured at the typical load and maximum load. 2.2 Output Specification 2.1 DC Voltage Regulation The DC output voltages will remain within the regulation ranges shown in Table 5 when measured ate the load end of the output connectors. The voltage regulation limits do not include the transient DC load changes, which are covered in Section 3.2.4. Table 3: DC Output voltage regulation limits
Parameter | Line Regulation | Load regulation | Cross regulation |
V1:24V | ±5.0% | ±5.0% | N/A |
2.2 DC Output Current Table4: DC output current limits
Parameter | Min Current | Rate Current | Max Current | Unit |
V1:24V | 0.1 | 0.75 | - | A |
2.3 Output Ripple and Noise The following table 5 is output ripple and noise requirements, it will be met throughout the load ranges specified in Section 2.2.2 and under all input voltage conditions as specified Section 2.1.1, Measurements will be made with an oscilloscope set to 20MHz bandwidth limit. The outputs will be bypassed with one 0.1uF multilayer (type X7R) and one 10uF tantalum electrolytic (low ESR) capacitors. Table 5: Output ripples and noise limits
Parameter | Max. |
V1:24V | 240mVp-p@25 degrees C |
2.4 Output Dynamic Load Response The output voltages will remain within specified regulation limit of the nominal set voltage for changes in load as specified below under the following load steps defined below table 8. At a slew rate of 0.1Amps/uS between 50Hz to 10 KHz. Table6: Output dynamic load response limits
Dynamic Load | DC Voltage Regulation |
50%~100%~50% | ±10% |
2.5 Overshoot at turn-on/ turn-off Any overshoot at turn on or turn off shall be less than 10% of rated output voltage. 2.3 Protection Function . 3.1 Short Circuit Protection An output short circuit is defined as any output impedance of less than 0.1 ohms. The power supply will protect without damage to overseers of to the unit (components, connectors, etc) under the input conditions specified in Section 3.1 above. 3.2 Over Current Protection The power supply shall meet the limitation requirement as below table without any damage, the unit shall recover and function automatically after the protection is removed. Table 7: Over Current Protection limits
Parameter | Max | Unit |
V1:12V | 1.5 | A |
2.4 Timing 4.1 Hold up Time Hold-up time no less than 5mS at 100Vac/47Hz input and no less than 10mS at 110/220Vac/50/60Hz input, the output loading should be set up with full load during the test. 4.2 Start up Time Start up time no more than 3 seconds at 100Vac/47Hz input and no more than 2 seconds at 110/220Vac/50/60Hz, the output loading should be set up with full load during the test.