1 / 1
$2000.00
≥10 Set/Sets
Model No. : | XYH |
---|---|
Types of : | Charging Station |
Jinan, Shandong, China
Product description
High frequency charging module is a necessary module in the DC charger of new energy electric vehicles.it can complete the function of alternating current to direct current, and supply electric energy safely, efficiently, quickly and reasonably to the power battery of electric vehicles.
Features:
1. Different power:7kw 15kw 22kw and 30kw
Different voltage:500V 750V 1000V
2. Full hot plug desgn
3. Inside high frequency transformer isolation
4. High efficiency over the full load range,full load efficiency higher than 95% Constant current for higher output power at low output voltage
5. Low Energy consumption
Unique sleep mode,less than 9W power
High conversion efficiency up to 96%
Intelligent parallel mode.working with the best efficiency.
Spec.:
7kw AC/DC Rectifier charging module input:90~280V/20A
Output:150-750Vdc/0~20A
Name
Parameter
Input
Phase
3P+PE
Voltage range
90~280Vac
Rated voltage
208Vac
Max. current
20A
Grid frequency
45~65Hz
Rated frequency
60Hz
DC output
Voltage range
50~750Vdc
Current range
0~20A
Rated current
9A@750v
Voltage stabilization accuracy
<±0.5%
Steady current accuracy
≤± 1% (output load 20% ~ 100% rated range)
Load adjustment rate
≤± 0.5%
Grid adjustment rate
≤± 0.1% (test range: 320v ~ 530v)
Start overshoot
≤±3%
THD
≤ 5% @ 50% ~ 100% full load
output power
Power factor
≥ 0.99 @100% full load output power, nominal input voltage and
frequency
Noisy
≤65dB(A) 1meter
Efficiency
≥ 95.2%, @750v, 50% ~ 100% load current, under the condition of
rated three-phase input voltage
Impulse current at the moment of startup
<30A
Current sharing
When the load is 10% - 100%, the current
sharing error of the module is ≤± 5% within the
rated output current
Grounding resistance
Grounding resistance ≤ 0.1 Ω, and it should be
able to withstand current ≥ 25A
Leakage current
Leakage current ≤ 3.5ma
Working temperature
- 40 ℃ ~ + 75 ℃, derating is required for use above 50 ℃
Relative humidity
≤ 95% RH, no condensation
Cooling mode
Forced air cooling
Altitude
2000m, derating is required for use above
2000m
Dimension W*L*H
385*178*87mm
Weight
10Kg
22kw AC/DC Rectifier charging module
input:260~530V/32A Output:150-750Vdc/0~50A
Name
Parameter
Input
Phase
3P+PE
Voltage range
260~530Vac
Rated voltage
400Vac
Max. current
32A
Grid frequency
45~65Hz
Rated frequency
50Hz/60Hz
DC output
Voltage range
50~750Vdc
Current range
0~33.3A (high voltage mode can be set
continuously) / 0~50A (low voltage mode can be set continuously)
Rated current
26A@750v (required for setting current
limiting point, 750V full power is 26.67A)
Voltage stabilization accuracy
<±0.5%
Steady current accuracy
≤± 1% (output load 20% ~ 100% rated range)
Load adjustment rate
≤± 0.5%
Grid adjustment rate
≤± 0.1% (test range: 320v ~ 530v)
Start overshoot
≤±3%
THD
≤ 5% @ 50% ~ 100% full load
output power
Power factor
≥ 0.99 @100% full load output power, nominal input voltage and
frequency
Noisy
≤65dB(A) 1meter
Efficiency
≥ 95.2%, @750v, 50% ~ 100% load current, under the condition of
rated three-phase input voltage
Impulse current at the moment of startup
<45A
Current sharing
When the load is 10% - 100%, the current
sharing error of the module is ≤± 5% within the
rated output current
Grounding resistance
Grounding resistance ≤ 0.1 Ω, and it should be
able to withstand current ≥ 25A
Leakage current
Leakage current ≤ 3.5ma
Working temperature
- 40 ℃ ~ + 75 ℃, derating is required for use above 50 ℃
Relative humidity
≤ 95% RH, no condensation
Cooling mode
Forced air cooling
Altitude
2000m, derating is required for use above
2000m
Dimension W*L*H
226*395*84mm
Weight
11.5Kg
30kw AC/DC Rectifier charging module
input:260~530V/48A Output:150-1000Vdc/0~100A
Name
Parameter
Input
Phase
3P+PE
Voltage range
260~530Vac
Rated voltage
400Vac
Max. current
60A
Grid frequency
45~65Hz
Rated frequency
50Hz/60Hz
Output
Voltage range
150~1000Vdc
Current range
0~100A
Rated current
30A@
Voltage stabilization accuracy
<±0.5%
Steady current accuracy
≤± 1% (output load 20% ~ 100% rated range)
Load adjustment rate
≤± 0.5%
Grid adjustment rate
≤± 0.1% (test range: 320v ~ 530v)
Start overshoot
≤±3%
THD
≤ 5% @ 50% ~ 100% full load
output power
Power factor
≥ 0.99 @100% full load output power, nominal input voltage and
frequency
Noisy
≤65dB(A) 1meter
Efficiency
≥ 95.2%,
Impulse current at the moment of startup
<72A
Current sharing
When the load is 10% - 100%, the current
sharing error of the module is ≤± 5% within the
rated output current
Grounding resistance
Grounding resistance ≤ 0.1 Ω, and it should be
able to withstand current ≥ 25A
Leakage current
Leakage current ≤ 3.5ma
Working temperature
- 40 ℃ ~ + 75 ℃, derating is required for use above 50 ℃
Relative humidity
≤ 95% RH, no condensation
Cooling mode
Forced air cooling
Altitude
2000m, derating is required for use above
2000m
Dimension W*L*H
385*395*110mm
Weight
21Kg
Jinan, Shandong, China
Send your inquiry to this supplier