Model No. : | INV-A1-4000W |
---|
Product description
Model |
2000W | ||||||
DC Input | 2KW: DC24V & DC48V(Select one) | ||||||
AC ouput | AC220V & AC110V & AC100V & AC230V & AC240V (Select one) | ||||||
Nominal Output Frequency (Hz) | 50HZ & 60HZ(Automatic selection) | ||||||
UPS function | Yes (Can give up the use ) | ||||||
AC charging function | Yes (Can give up the use ) | ||||||
Utility Model Specifications | |||||||
AC220V | AC110V | ||||||
Efficiency | ≥ 98% | ||||||
Input Wave Type | Pure sine wave (utility or generator) | Pure sine wave (utility or generator) | |||||
Input Voltage Range | AC 154V~AC263V | AC 77V~132V | |||||
Nominal Input Voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | |||||
Low Voltage shutoff | 154Vac± 4% | 77Vac± 4% | |||||
Low Voltage Recovery | 164Vac ± 4% | 82Vac ± 4% | |||||
Over voltage Shut off | 263Vac± 4% | 132Vac± 4% | |||||
Over Voltage Recovery | 253Vac± 4% | 127Vac± 4% | |||||
Nominal Input Frequency | 50Hz/ 60Hz (auto detect) | 50Hz/ 60Hz (auto detect) | |||||
Output Wave Type | Same as the input wave type | Same as the input wave type | |||||
Transfer Time (Ac to Dc) | < 10ms | < 10ms | |||||
Transfer Time (Dc to Ac) | < 5ms | < 5ms | |||||
Inverter Mode Specification | |||||||
Power Factor | 1 (Sufficient output power) | ||||||
Rated Output Voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | |||||
Nominal Output Frequency (Hz) | 50/60 ± 0.3Hz (auto detect) | ||||||
Output Voltage Range | ± 10% rms | ||||||
Efficiency | > 88% (DC12V: > 88%, DC24V: > 90%, DC48V: > 94%) | ||||||
Over-Load Protection | (110%< load< 125%) ± 10%: Fault (shutdown output) after 15 minutes; | ||||||
(125%< load< 150%) ± 10%: Fault (shutdown output) after 10s; | |||||||
Load> 150% ± 10%: Fault (shutdown output) after 20s; | |||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc (If 12V Input) | ||||||
21.0Vdc ± 0.6Vdc (If 24V Input) | |||||||
42.0Vdc ± 0.6Vdc (If 48V Input) | |||||||
Low DC input voltage automatic shut-down | 10.0Vdc ± 0.3Vdc(If 12V Input) | ||||||
20.0vdc± 0.6Vdc (If 24V Input) | |||||||
40.0vdc± 0.6Vdc (If 48V Input) | |||||||
High DC input voltage warning & outage | 16Vdc ± 0.3Vdc (If 12V Input) | ||||||
32Vdc ± 0.6Vdc (If 24V Input) | |||||||
64Vdc ± 0.6Vdc (If 48V Input) | |||||||
High DC input voltage Recover | 15.5Vdc ± 0.3Vdc(If 12V Input) | ||||||
31.0Vdc ± 0.6Vdc (If 24V Input) | |||||||
62.0Vdc ± 0.6Vdc (If 48V Input) | |||||||
Power-saving mode | < 10W | ||||||
Power on mode | 20W~60W | ||||||
Safety | CE, EMC, LVD, SGS, ISO9001 | ||||||
Communication port | RS232 | ||||||
Cooling | Cooling-Variable Speed Fan run under ventilation condition. | ||||||
Operating Temperature Range | 0° Cto 60° C | ||||||
Storage temperature | -15º C~60º C | ||||||
humidity | 5% to 95% | ||||||
Noise | Max 60dB | ||||||
Detailed parameters of electrified wire netting to battery charging | |||||||
If you want to purchase this product, Please make sure the following parameters. | |||||||
Power rating | 2KW | ||||||
DC volts | DC12V & DC24V & DC48V & DC36V | ||||||
AC volts | AC110V & AC220V & AC100V & AC120V & AC230V & AC240V | ||||||
Frequency | 50HZ & 60HZ | ||||||
The UPS function | YES & NO | ||||||
The use of occasions | Solar & Wind & Car & Family expenses & Industrial use & other | ||||||
AC priority use & DC priority use | AC priority use & DC priority use | ||||||
If DC priority use | There are two kinds of programming: 1, every time itstarts, After the batteris is full, and then converted to DC supply. 2, After the batteris is 13.5V/27V/54V, and then converted to DC supply. | ||||||
AC charging function | YES & NO | ||||||
Trade Terms | EXW, FOB, FCA, FAS, CIF, CFR, DEQ, and so on | ||||||
Other description | |||||||