Product description
Specifications:
- Capacity: 45kVA
- Circuit type: IGBT/pulse width modulation type
- Input voltage: 380VAC/220±10% or customized
- Input frequency: 50Hz/60Hz
- Input phase: 3 phases
- Output voltage: 2 ranges
- Low: 0-260V AC (adjustable)
- High: 0-500V AC (adjustable)
- Output hertz: 50/60Hz/45-65Hz (variable)
- Output phase: 3 phase
- Output maximum current: 96A per phase for low voltage range and 50A per phase for high-voltage range
- Frequency regulation: ±0.01%/0.5%
- Response time: <20s
- Distortion: clean sine wave THD <3%
- Protection: over-voltage, overload, thermal protection, short-circuit protection, alarm system
- Display:
- Digital frequency meter: 0.1Hz
- Digital voltage meter: 0.1V
- Digital current meter: 0.01A
- Digital power meter: 0.1W
- Dimensions: 1,320*600*1370mm (450kg)
- Temperature: -10-50°C
- Noise: <50dB within 1 meter
- Humidity: 5-90% RH (non-condensing)
Details:
- Wide range of capacity from 500VA to 2,000kVA
- Single and three phase units available, with optional phase conversion
- Suitable for resistive, capacitive, inductive and non-linear loads
- Isolated input to output, no harmonic distortion (EMI, EMC)
- IGBT based, generating high efficiency, low noise and maximum reliability
- Enable testing of electronic or electrical products manufactured for commercial aircraft, military and aerospace equipment such as airborne electronics, aircraft galley equipment, ground support or radar systems
Theory of ACSOON power:
- Theory of operation: series AF60, AF50, AF400, frequency converters/AC power source are designed to change conventional 50Hz or 60Hz electrical energy to virtually any other frequency
- The frequency conversion is accomplished in a two (2)-stage process
- The first stage converts the incoming alternating supply voltage to a controlled DC voltage (rectification)
- The second stage inverts the DC voltage to an alternating supply voltage at the desired output frequency (inversion)
Capacity: 45kVA
Circuit type: IGBT/pulse width modulation type
Input voltage: 380VAC/220±10% or customized
Input frequency: 50Hz/60Hz
Input phase: 3 phases
Output voltage: 2 ranges
- Low: 0-260V AC (adjustable)
- High: 0-500V AC (adjustable)
Output hertz: 50/60Hz/45-65Hz (variable)
Output phase: 3 phase
Output maximum current: 96A per phase for low voltage range and 50A per phase for high-voltage range
Frequency regulation: ±0.01%/0.5%
Response time: <20s
Distortion: clean sine wave THD <3%
Protection: over-voltage, overload, thermal protection, short-circuit protection, alarm system
Display:
- Digital frequency meter: 0.1Hz
- Digital voltage meter: 0.1V
- Digital current meter: 0.01A
- Digital power meter: 0.1W
Dimensions: 1,320*600*1370mm (450kg)
Temperature: -10-50°C
Noise: <50dB within 1 meter
Humidity: 5-90% RH (non-condensing)
Low: 0-260V AC (adjustable)
High: 0-500V AC (adjustable)
Digital frequency meter: 0.1Hz
Digital voltage meter: 0.1V
Digital current meter: 0.01A
Digital power meter: 0.1W
Wide range of capacity from 500VA to 2,000kVA
Single and three phase units available, with optional phase conversion
Suitable for resistive, capacitive, inductive and non-linear loads
Isolated input to output, no harmonic distortion (EMI, EMC)
IGBT based, generating high efficiency, low noise and maximum reliability
Enable testing of electronic or electrical products manufactured for commercial aircraft, military and aerospace equipment such as airborne electronics, aircraft galley equipment, ground support or radar systems
Theory of operation: series AF60, AF50, AF400, frequency converters/AC power source are designed to change conventional 50Hz or 60Hz electrical energy to virtually any other frequency
The frequency conversion is accomplished in a two (2)-stage process
The first stage converts the incoming alternating supply voltage to a controlled DC voltage (rectification)
The second stage inverts the DC voltage to an alternating supply voltage at the desired output frequency (inversion)