Product description

210KW(L) 3 phase Super Power Module Online UPS        Features   * Output power factor 1 * N+1 or N+R Parallel Redundancy for power guarantee * Modular design decreases MTTR * High scalability * Built-in maintenance bypass switch for easy maintenance without interruptible * High efficiency double conversion online UPS * Adjustable battery numbers * Adjustable charging current *Graphic 5.7'' LCD design for easy configuration     Specification  
SUPER POWER MODULE ONLINE UPS SELECTION GUIDE
MODEL LD-33T-90K LD-33T-120K LD-33T-120K(L) LD-33T-180K(L) LD-33T-210K(L)
PHASE 3-phase in/3-phase out
CABINET CAPACITY* 90KW 120KW 120KW 180KW 210KW
BATTERY TYPE Built-in Battery External Battery
One Power Module Capacity 30KVA/30KW 30KVA/30KW or 20KVA/20W 30KVA/30KW
Max. Power Module No. 3 4 4 6 8
Max. Battery Set No.** 3 5 - - -
INPUT
Nominal Voltage  3 x 400 VAC (3Ph+N) 
Voltage Range  305 ~ 477 VAC at 100% load; 208 ~ 304VAC at <70% load
Nominal Frequency  50/60Hz (Auto sensing)
Frequency Range  40Hz ~70Hz
Power Factor  > 0.99 at 100% load, >0.98 at 50% load
Harmonic Distortion (THDi) < 3% @ 100% load
OUTPUT
Nominal Voltage  3 x 400 VAC (3Ph+N) 
Voltage Regulation (Steady state) ± 1% Typical (balanced load)
± 2% Typical (unbalanced load)
Voltage Regulation (Transient) ± 5% Typical 
Nominal Frequency  50/60Hz
Frequency Range (Synchronized range) 46Hz ~ 54Hz or 56Hz ~ 64Hz 
Overload Capability  1 hour for 110%, 10 mins for 120%, 1 min for 150% and 200ms for >150%
Harmonic Distortion  1.5% THD (Linear Load)
 4% THD (Non-linear Load)
Efficiency  Up to 94.5%
BATTERY / CHARGER
Nominal Voltage  +/-  216V (12V x 36 Pcs)
Maximum Voltage  +/- 240V (12V x 40 Pcs)
Minimum Voltage  +/- 192V (12V x 32 Pcs)
Floating Charge Voltage  2.25V/Cell
Boost Charging Voltage  2.35V/Cell
Temperature Compensation  Yes
Maximum Charging Current 8A for each power module (User-djustable)
PHYSICAL
Cabinet Dimension
(D x W x H) mm
1100 x 600 x 1475  1100 x 600 x 2010 1100 x 600 x 1475  1100 x 600 x 1475  1100 x 600 x 2010
Net Weight (kgs) 675.5 932 335 453.5 549
ENVIRONMENT
Operation Temperature  0 ~ 40
Relative Humidity  0 ~ 95% non-condensing
Altitude *** <1000m for Nominal power
IP Class  IP 20
MANAGEMENT
RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 60950-1; IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
*When temperature is above 30, the output power factor will be de-rated, 0.9 at 31~35 and 0.8 at 36~40
** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules. 
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.
           
Model Description Dimension DxWxH(mm) Weight (kg)
PM-30HV 3P/3P 30KVA/30KW power module 650x440x132(3U) 34.5
PM-20HV 3P/3P 20KVA/20KW power module 650x440x132(3U) 34
Battery Module 10 pcs of 12V/9Ah batteries  735x107x155 26